junidApsChanConfigIfIndex
APS-MIB-JUNI ·
.1.3.6.1.4.1.4874.3.2.2.1.1.4.1.4
Object
The Interface Index assigned to a SONET LTE. This is an
interface with ifType sonet(39). The value of this object
must be unique among all instances of junidApsChanConfigIfIndex.
In other words, a particular SONET LTE can only be configured in
one APS group.
This object cannot be set if the junidApsChanConfigGroupName instance
associated with this row is equal to an instance of junidApsConfigName and
the corresponding junidApsConfigRowStatus object is set to active. In
other words this value cannot be changed if the APS group is active.
However, This value may be changed if the junidApsConfigRowStatus value is
equal to notInService.
Context
- MIB
- APS-MIB-JUNI
- OID
.1.3.6.1.4.1.4874.3.2.2.1.1.4.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- junidApsChanConfigEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'APS-MIB-JUNI' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'APS-MIB-JUNI::junidApsChanConfigIfIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'APS-MIB-JUNI' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'APS-MIB-JUNI::junidApsChanConfigIfIndex.<junidApsChanConfigGroupName>.<junidApsChanConfigNumber>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'APS-MIB-JUNI' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'APS-MIB-JUNI::junidApsChanConfigIfIndex'
Syntax
- Source
- IF-MIBInterfaceIndex
- Base type
Integer32- Display format
d
Type Description
A unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Values & Constraints
Type Constraints
range: 1..2147483647
Conformance
Member of
Compliance refinements
junidApsCompliance
readonly
Write access is not required.