aluExtPortEtherAdminPhyTxClock
ALU-PORT-MIB ·
.1.3.6.1.4.1.6527.6.1.2.2.2.4.2.1.11
Object
column
r/w
Enumeration
The value of aluExtPortEtherAdminPhyTxClock indicates the mode
used to establish timing control of a 1000BASE-T port. The
aluExtPortEtherAdminPhyTxClock is used to control the setting
of register 9, bits 10-12 that are described in Table 40-3 of
IEEE 802.3-2008.
Register 9.12, the MASTER-SLAVE Manual Config Enable bit, is
cleared when 'auto-pref-slave (3)' or 'auto-pref-master (4)'
is configured. Otherwise the register 9.12 bit is set.
Register 9.10 will be cleared when 'auto-pref-slave (3)' is
configured and 'auto-pref-master (4)' will cause register 9.10
to be cleared.
When aluExtPortEtherAdminPhyTxClock is 'slave (1)', register
9.11, the MASTER-SLAVE Manual Config Value bit, is cleared. When
aluExtPortEtherAdminPhyTxClock is 'master (2)' MASTER-SLAVE
Manual Config Value bit is set.
For ports that cannot support 1000BASE-T, aluExtPortEtherAdminPhyTxClock
will be defaulted to 'notApplicable (0)' and cannot be changed.
For ports that support 1000BASE-T, setting aluExtPortEtherAdminPhyTxClock
to 'notApplicable (0)' will result in aluExtPortEtherAdminPhyTxClock
being set to the DEFVAL value of 'auto-pref-slave (3)'.
Setting aluExtPortEtherAdminPhyTxClock on 1000BaseT microwave aware
ports (ie. ports associated with ALU-MICROWAVE-PORT::aluMwRadioPortID)
is allowed but it does not establish timing control of the 1000BASE-T
port. The operational aspects of microwave ports with respect to timing
control is described under aluExtPortEtherOperPhyTxClock
Context
- MIB
- ALU-PORT-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.2.2.4.2.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- aluExtTmnxPortEtherEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | notApplicable |
1 | slave |
2 | master |
3 | auto-pref-slave |
4 | auto-pref-master |