tmnxTestHdSapPortId

ALU-OAM-TEST-MIB · .1.3.6.1.4.1.6527.6.1.2.2.21.1.6.14

Object

The Sap Port ID to be used for the test run, it has to be supplied
along with tmnxTestHdSapEncapValue when the test is started.

Context

MIB
ALU-OAM-TEST-MIB
OID
.1.3.6.1.4.1.6527.6.1.2.2.21.1.6.14
Type
scalar
Access
readwrite
Status
current
Parent
tmnxTestHdProfScalarObjs
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ALU-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-OAM-TEST-MIB::tmnxTestHdSapPortId.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ALU-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ALU-OAM-TEST-MIB::tmnxTestHdSapPortId'

Syntax

Source
TIMETRA-TC-MIBTmnxPortID
Base type
Unsigned32
Type Description
A portid is a unique 32 bit number with special encoding.
          
Refer to TIMETRA-CHASSIS-MIB::tmnxChassisPortIdScheme for a
description of the various port mapping schemes used by the system for
physical ports and channels.
          
An 'invalid portid' is a TmnxPortID with a value of 0x1e000000.

Values & Constraints

No enumerated values or constraints recorded.