aluPwrEthExternPsStatus
ALU-CHASSIS-MIB ·
.1.3.6.1.4.1.6527.6.1.2.3.2.1.0.16
Object
notification
The aluPwrEthExternPsStatus notification is generated when Poe external power supply presence changes
Context
- MIB
- ALU-CHASSIS-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.3.2.1.0.16- Type
- notification
- Status
- current
- Parent
- aluChassisNotification
- Siblings
- 17
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| aluEqExtAlarmDetected The aluEqExtAlarmDetected notification is generated when an alarm condition
from the external alarm interface is detected. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.1 |
| aluSyncIfTimingRefSwitch Generated when there is a change of which timing reference
is providing timing for the system. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.10 |
| aluChassisConsoleAccessed Generated when there a user attempts to access CLI via the console port. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.11 |
| aluChassisMgmtPortAccessed Generated when there a user attempts to access CLI via the local management
ethernet port or in-band management. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.12 |
| aluEqMdaCriticalRuntimeError Generated when the MDA has experienced a critical runtime Error
(eg. FATAL FIB Error). | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.13 |
| aluSyncIfTimingRef1Ref2Switch Generated when there is a change of which timing reference
is providing timing for the system. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.14 |
| aluPwrEthPowerSupplyStatus The aluPwrEthPowerSupplyStatus notification is generated when Poe
power supply state changes | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.15 |
| aluInvalidDcPowerInput The aluInvalidDcPowerInput notification is
generated when a 7705 SAR-H chassis has both
AC and DC power inputs | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.17 |
| aluChassisSystemId The aluChassisSystemId notification is
generated when the chassis system ID is configured | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.19 |
| aluEqExtAlarmCleared The aluEqExtAlarmCleared notification is generated when an alarm condition
from the external alarm interface is cleared. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.2 |
| aluEqBgDiagsFault The 'aluEqBgDiagsFault' is generated when a background diagnostic running
on a hardware component has detected a fault.
aluExtHwBgDiagsFaultReason indicates the fault detected. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.3 |
| aluEqSyncIfTimingExternAlarm Generated when an alarm condition on the external input
timing reference is detected. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.4 |
| aluEqSyncIfTimingExternAlarmClear Generated when an alarm condition on the External input
timing reference is cleared. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.5 |
| aluEqFanMinorFailure Generated when a minor fan failure has been detected by
the system. On the device a single fan failure is
considered a minor failure as the device can operate
normally in this c… | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.6 |
| aluEqFIBOutOfSynch Generated when the FIB has been detected to be out of
synch on the specified equipment | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.7 |
| aluEqFIBOutOfSynchClr Generated when the FIB is back in synch on the specified
equipment. | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.8 |
| aluEqMdaRuntimeStatus Generated when the MDA has experienced a runtime status event
worthy of reporting (eg. MIPS CPER has occurred). | notification | - | .1.3.6.1.4.1.6527.6.1.2.3.2.1.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| aluExtTmnxMDAPwrEthPsExternalPowerSupplyStatus Current status of the power ethernet External Power Supply connection | column | Enumeration | .1.3.6.1.4.1.6527.6.1.2.2.2.1.4.1.14 |