alaRipngInvalidTimer
ALCATEL-IND1-RIPNG-MIB ·
.1.3.6.1.4.1.6486.800.1.2.1.10.12.1.1.1.3
Object
scalar
r/w
seconds Integer32
Time in seconds that a route will remain active in RIB before being moved to the invalid state. The value must be at least three times the update interval. The defined range of 1 to 360 allows backwards compatibility with older devices which do not enforce the three-times constraint. For newer devices which enforce the three-times constraint with the update interval, the minimum allowed value of the invalid timer is 3.
Context
- MIB
- ALCATEL-IND1-RIPNG-MIB
- OID
.1.3.6.1.4.1.6486.800.1.2.1.10.12.1.1.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- alaProtocolRipng
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 1-360