alaErpRingGuardTimer
ALCATEL-IND1-ERP-MIB ·
.1.3.6.1.4.1.6486.800.1.2.1.46.1.1.2.1.1.9
Object
column
r/w
10 milliseconds Integer32
Defines the guard timer value in centiseconds.
This timer is started to prevent the ring nodes from receiving
outdated R-APS messages.
It may be configured by the operator in 10 ms steps between
10 ms to 2 seconds.
Context
- MIB
- ALCATEL-IND1-ERP-MIB
- OID
.1.3.6.1.4.1.6486.800.1.2.1.46.1.1.2.1.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 10 milliseconds
- Parent
- alaErpRingEntry
Syntax
10 milliseconds Integer32
Values & Constraints
Object Constraints
range: 1-200