tmnxOamTrCtlInterval

ALCATEL-ENT1-TIMETRA-OAM-TEST-MIB · .1.3.6.1.4.1.6527.3.1.2.11.2.3.1.19

Object

column r/w seconds Unsigned32
The value of tmnxOamTrCtlInterval specifies the number of seconds
to wait before repeating an Alcatel 7x50 SR OAM Trace Route test as
defined by the value of the various objects in the corresponding row.
This parameter is optional.
              
The number of hops in a single Alcatel 7x50 SR OAM Trace Route test
is determined by the value of the corresponding
tmnxOamTrCtlProbesPerHop object.  After a single test completes,
the number of seconds as defined by the value of
tmnxOamTrCtlInterval MUST elapse before the next Alcatel 7x50 SR
OAM Trace Route test is started.
              
A value of 0 for this object implies that the test as defined by the 
corresponding entry will not be repeated.
              
This parameter is not used by 'icmpTraceRoute'.

Context

MIB
ALCATEL-ENT1-TIMETRA-OAM-TEST-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.11.2.3.1.19
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
tmnxOamTrCtlEntry

Syntax

seconds Unsigned32

Values & Constraints