neDateAndTime

ADVA-MIB · .1.3.6.1.4.1.2544.2.1.3

Object

Reports the current local time on the Network Element.
It also allows to set the local time. However, SET
requests may not be supported by all products.

Context

MIB
ADVA-MIB
OID
.1.3.6.1.4.1.2544.2.1.3
Type
scalar
Access
readwrite
Status
current
Parent
neInfo

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ADVA-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ADVA-MIB::neDateAndTime.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADVA-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADVA-MIB::neDateAndTime'

Syntax

Source
SNMPv2-TCDateAndTime
Base type
OctetString
Display format
2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Type Description
A date-time specification.
          
field  octets  contents                  range
-----  ------  --------                  -----
  1      1-2   year*                     0..65536
  2       3    month                     1..12
  3       4    day                       1..31
  4       5    hour                      0..23
  5       6    minutes                   0..59
  6       7    seconds                   0..60
               (use 60 for leap-second)
  7       8    deci-seconds              0..9
  8       9    direction from UTC        '+' / '-'
  9      10    hours from UTC*           0..13
 10      11    minutes from UTC          0..59
          
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
          
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
          
                 1992-5-26,13:30:15.0,-4:0
          
Note that if only local time is known, then timezone
information (fields 8-10) is not present.

Values & Constraints

Type Constraints
range: 8 range: 11