moduleCapChannelSpacing
ADVA-FSPR7-CAP-MIB ·
.1.3.6.1.4.1.2544.1.11.9.3.3.7.1.35
Object
column
ADVA-FSPR7-TC-MIBFspR7ChannelSpacingCaps
ITU Grid channel spacing
Context
- MIB
- ADVA-FSPR7-CAP-MIB
- OID
.1.3.6.1.4.1.2544.1.11.9.3.3.7.1.35- Type
- column
- Access
- readonly
- Status
- current
- Parent
- moduleCapEntry
- Table
- moduleCapTable
- Siblings
- 42
Syntax
ADVA-FSPR7-TC-MIBFspR7ChannelSpacingCaps
- Source
- ADVA-FSPR7-TC-MIBFspR7ChannelSpacingCaps
- Base type
Bits
Values & Constraints
Type Values
0 | capUndefined |
1 | capSpacing50Ghz |
2 | capSpacing100Ghz |
3 | capSpacing200Ghz |
4 | capSpacing25GHz |
5 | capSpacingFlex |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| moduleCapRowStatus RowStatus object is used to create or delete a row in the table. | column | ADVA-FSPR7-TC-MIBFspR7RowStatusCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.1 |
| moduleCapGainRange EDFA gain range to provision | column | ADVA-FSPR7-TC-MIBFspR7GainRangeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.10 |
| moduleCapSfProvision determines the location (A or B) for Single Fiber applications | column | ADVA-FSPR7-TC-MIBFspR7SingleFiberLocationCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.11 |
| moduleCapCapabilityLevelProvision Capability level provisioned | column | ADVA-FSPR7-TC-MIBFspR7CapInventoryCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.12 |
| moduleCapDCFiberType Dispersion Compensation Fibertype | column | ADVA-FSPR7-TC-MIBFspR7DCFiberTypeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.13 |
| moduleCapChannelsProvision Number of channels supported by an entity | column | ADVA-FSPR7-TC-MIBFspR7NumberOfChannelsProvCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.14 |
| moduleCapFiberDetect Fiber Detect | column | ADVA-FSPR7-TC-MIBFspR7FiberDetectCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.15 |
| moduleCapSupply The kind of power supply - provisioned value | column | ADVA-FSPR7-TC-MIBFspR7SupplyTypeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.16 |
| moduleCapGroup The Group of 4 DWDM channels or the Group of 4 CWDM channels | column | ADVA-FSPR7-TC-MIBFspR7OpticalGroupCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.17 |
| moduleCapDeploy Describes how the card is applied related to a network scenario | column | ADVA-FSPR7-TC-MIBFspR7DeploymentScenarioCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.18 |
| moduleCapLagSysPrio Link Aggregation Group Actor System Priority Part of LAG ID | column | ADVA-FSPR7-TC-MIBFspR7Unsigned32Caps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.19 |
| moduleCapForceDestroy Forced Destroy | column | ADVA-FSPR7-TC-MIBFspR7ForcedStatusCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.2 |
| moduleCapTransmitChannel Channel | column | ADVA-FSPR7-TC-MIBFspR7ChannelIdentifierCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.20 |
| moduleCapBand The optical band of the module. | column | ADVA-FSPR7-TC-MIBFspR7OpticalBandCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.21 |
| moduleCapTrafficDirection Traffic Direction | column | ADVA-FSPR7-TC-MIBFspR7TrafficDirectionCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.22 |
| moduleCapIpAddr IP Address assigned to LAN IP Interface | column | ADVA-FSPR7-TC-MIBFspR7YesNo | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.23 |
| moduleCapDispersionCompensation Dispersion Compensation Value in km of SSMF fiber | column | ADVA-FSPR7-TC-MIBFspR7DispersionCompensationCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.24 |
| moduleCapActivateDetect Initialize Topology Detection | column | ADVA-FSPR7-TC-MIBFspR7YesNoCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.25 |
| moduleCapOscUsage Select if and how the OSC is to be used on an amplifier | column | ADVA-FSPR7-TC-MIBFspR7OscUsageCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.26 |
| moduleCapAdmin The Administrative State will be displayed in the GUI with full
name values; it will be differently displayed in TL1 syntax according
to TL1 display rules. The transaction into th… | column | ADVA-FSPR7-TC-MIBFspR7AdminStateCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.27 |
| moduleCapScrambling Configuration of scrambling functionality for Virtual Facilities | column | ADVA-FSPR7-TC-MIBFspR7ScramblingCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.28 |
| moduleCapChannelsNumber Number of channels supported by an entity | column | ADVA-FSPR7-TC-MIBFspR7NumberOfChannelsCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.29 |
| moduleCapPsuOutputPower Maximum PSU Output Power | column | ADVA-FSPR7-TC-MIBFspR7PsuOutputPowerCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.3 |
| moduleCapChannelSpacingProvision Channel Space Provision, reference to CHA-SPC__INVENTORY | column | ADVA-FSPR7-TC-MIBFspR7ChannelSpacingCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.30 |
| moduleCapMode Mode of the module, determine operation or functionality | column | ADVA-FSPR7-TC-MIBFspR7TransmissionModeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.31 |
| moduleCapSubBandProvision Subband - Provision | column | ADVA-FSPR7-TC-MIBFspR7OpticalSubBandCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.32 |
| moduleCapAlias User Applied Descriptor | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.33 |
| moduleCapFiberType Fiber of Optical Interface - Provision, Reference to FIBER__INVENTORY | column | ADVA-FSPR7-TC-MIBFspR7OpticalFiberTypeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.34 |
| moduleCapOutputReset Has the same function as the HW switch at the UTM board | column | ADVA-FSPR7-TC-MIBFspR7TifOutputResetCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.36 |
| moduleCapRoadmNumber Number for ROADM module typically associated with a Network Fiber or Degree | column | ADVA-FSPR7-TC-MIBFspR7RoadmNumberCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.37 |
| moduleCapTopology Shows the card topology in the NE | column | ADVA-FSPR7-TC-MIBFspR7TopologyCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.38 |
| moduleCapForceConfig Force cserver to send down configuration to module | column | ADVA-FSPR7-TC-MIBFspR7ForceConfigCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.39 |
| moduleCapPower Optical Output Power Rating - Provision | column | ADVA-FSPR7-TC-MIBFspR7EdfaOutputPowerRatingCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.4 |
| moduleCapMuxMethod Selection of mux method | column | ADVA-FSPR7-TC-MIBFspR7MuxMethodCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.40 |
| moduleCapNdpCleanup Cleanup Network Data Path allocation | column | ADVA-FSPR7-TC-MIBFspR7NdpCleanupCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.41 |
| moduleCapRstp Rapid spanning tree protocol | column | ADVA-FSPR7-TC-MIBFspR7EnableDisableCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.42 |
| moduleCapRemoteReset Remote reset of module. This parameter will be available only on SH9HU and SH1HUPF shelves. | column | ADVA-FSPR7-TC-MIBFspR7RlsManCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.43 |
| moduleCapReach Reach | column | ADVA-FSPR7-TC-MIBFspR7OpticalInterfaceReachCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.5 |
| moduleCapInitEqlz Initiate Equalization | column | ADVA-FSPR7-TC-MIBFspR7InitEqualizationCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.6 |
| moduleCapLanAid AID of LAN | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.7 |
| moduleCapType The TYPE of Equipment and the MODE setting determine uniquely the number and allowed TYPE's of the provisionable dependent entities (plugs, interfaces, modules) | column | ADVA-MIBFspR7EquipmentTypeCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.8 |
| moduleCapMapping Type of mapping; transparent or framing | column | ADVA-FSPR7-TC-MIBFspR7MappingCaps | .1.3.6.1.4.1.2544.1.11.9.3.3.7.1.9 |