adGenCSMPortDefaultCDVT
ADTRAN-GENCSM2-MIB ·
.1.3.6.1.4.1.664.5.36.6.18.1.23
Object
column
r/w
100 nanoseconds Unsigned32
Port-wide default input CDVT setting. If this value is non-zero
and the traffic descriptor for does not explicitly state a
CDVT value, this value is used as the 'implied' CDVT. If this
value is zero, a calculated valued based on the PCR of the
Traffic descriptor is used instead. Currently, this calculated
value is 100 * PCR of the circuit being admitted.
Changing the default input CDVT value will not affect any VC or
VP cross connects that are currently in the 'active' state.
These VC/VP cross Connects will continue to use the CDVT value
that was in effect when the VC/VP cross connect was made active.
The new input CDVT value will be used on these VC/VP cross
connects the next time they are placed in a notInService state
or the CSM is rebooted.
If the override flag is set to false, then this value is read-only
and is inherited from the setting of the adGenCSMDirectionDefaultCDVT
variable.
Context
- MIB
- ADTRAN-GENCSM2-MIB
- OID
.1.3.6.1.4.1.664.5.36.6.18.1.23- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 100 nanoseconds
- Parent
- adGenCSMPortOptionEntry
Syntax
100 nanoseconds Unsigned32
Values & Constraints
No enumerated values or constraints recorded.