adGenCSMMonitorSessionEntry
ADTRAN-GENCSM2-MIB ·
.1.3.6.1.4.1.664.5.36.7.2.1
Object
row
An entry in the adGenCSMMonitorSessionTable. An entry
in this table is used to model a data collection interval
that has specific levels of scope. Depending upon the
capabilities of the particular CSM, only a limited
number of Monitoring Sessions (table rows) may be active
at any given time. Typically there can be many more
rows defined in the table if they are not active. This
will allow the administrator to store sessions when they
are not needed but may be needed in the future.
Step-wise Procedures to set up a Monitoring Session
(1) The manager obtains a unique adGenCSMMonitorSessionId
by reading the adGenCSMMonitorSessionIndexNext object.
(2) Next, the manager creates a row in the Monitor Session
Table. Each row is indexed by the
adGenCSMMonigorSessionId obtained in step 1 of this
procedure. The row can be created in this type by
setting the adGenCSMMonitorSessionRowStatus to
createAndWait(5). Row creation fails if:
- A row already exists with the specified index.
- Insufficient memory resources exist within the CSM.
(3) The manager sets any column values, besides the rowStatus
to specify the scope and duration of the monitor session.
The adGenCSMMonitorSessionRowStatus can be monitored to
determine if the row has valid parameters. When the
rowStatus is notReady(3), one or more parameters are
invalid for the scope level specified. When the rowStatus
is notInService(2), all columns are valid and the row is
ready to be made active(1).
(4) The manager sets the adGenCSMMonitorSessionRowStatus
object to active(1). This will initiate the monitoring
session and it will continue until the maximum number of
intervals, specified by adGenCSMMonitorSessionMaxIntervals,
is reached. If adGenCSMMonitorSessionMaxIntervals is
zero, the monitor session will continue to run until the
manager sets the adGenCSMMonitorSessionRowStatus object
to notInService(2) or destroy(6). If a power cycle/reset
occurs, the monitoring session will begin again at the
first interval upon restart of the CSM. If the maximum
number of active monitoring sessions has already been
reached, the setting of the adGenCSMMonitorSessionRowStatus
object to active(1) will fail.
*** It should be noted that data collected during a
monitoring session is not preserved across protection
switches at this time.
Context
- MIB
- ADTRAN-GENCSM2-MIB
- OID
.1.3.6.1.4.1.664.5.36.7.2.1- Type
- row
- Status
- current
- Parent
- adGenCSMMonitorSessionTable
- Table
- adGenCSMMonitorSessionTable
- Children
- 14
Syntax
No syntax metadata recorded.
Values & Constraints