acMGCallAgentPort
AC-CONTROL-MIB ·
.1.3.6.1.4.1.5003.9.10.5.1.3.1.2
Object
scalar r/w
Unsigned32
Defines the Call Agent port number. Defaults to the MGCP default
port number of 2427.
Range: 0 to 65534.
Access: Offline.
AC INI-Param: CALLAGENTPORT
Context
- MIB
- AC-CONTROL-MIB
- OID
.1.3.6.1.4.1.5003.9.10.5.1.3.1.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- acMGCallAgent
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'AC-CONTROL-MIB' -M '/opt/observium/mibs/mediant:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AC-CONTROL-MIB::acMGCallAgentPort.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'AC-CONTROL-MIB' -M '/opt/observium/mibs/mediant:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'AC-CONTROL-MIB::acMGCallAgentPort'
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-65534