acAuxiliaryFilesFxoCoefficients
AC-ANALOG-MIB ·
.1.3.6.1.4.1.5003.9.10.8.1.1.2.2
Object
Defines the FXO loop coefficient filename.
Max. 47 characters.
AC INI-Param: FXOCOEFFILENAME
Context
- MIB
- AC-ANALOG-MIB
- OID
.1.3.6.1.4.1.5003.9.10.8.1.1.2.2- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- acAuxiliaryFiles
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'AC-ANALOG-MIB' -M '/opt/observium/mibs/mediant:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AC-ANALOG-MIB::acAuxiliaryFilesFxoCoefficients.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'AC-ANALOG-MIB' -M '/opt/observium/mibs/mediant:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'AC-ANALOG-MIB::acAuxiliaryFilesFxoCoefficients'
Syntax
- Source
- SNMP-FRAMEWORK-MIBSnmpAdminString
- Base type
OctetString
Values & Constraints
Object Constraints
range: 0-47
Type Constraints
range: 0..255