a3ComPollResponseTimeOut

A3COM-SWITCHING-SYSTEMS-POLL-MIB · .1.3.6.1.4.1.43.29.4.22.1.1.7

Object

column mandatory r/w Integer32
Maximum wait time, in msecs, for a response packet before deciding 
that no response arrived. This object differs from a3ComPollRate 
as the device have the sending and receiving queues independent, 
making it possible to send ping requests at rates faster than  
receiving. 
              
The value of 0 (default) will be interpreted as a request for 
time-out by the time a new packet is sent, and 65535 as a request for 
maximum wait. Assuming that burst is used and this object is set to 
one, most likely all packets sent will be interpreted as timed out. 
              
This object may not be modified if the associated a3ComPollReport 
is equal to busy(2). When this object is successfully set,  
a3ComPollReport will be set to idle(1).

Context

MIB
A3COM-SWITCHING-SYSTEMS-POLL-MIB
OID
.1.3.6.1.4.1.43.29.4.22.1.1.7
Type
column
Access
readwrite
Status
mandatory
Parent
a3ComPollEntry
Table
a3ComPollTable
Siblings
17

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects

Sibling Objects