a3ComPollPacketSize
A3COM-SWITCHING-SYSTEMS-POLL-MIB ·
.1.3.6.1.4.1.43.29.4.22.1.1.8
Object
column
mandatory
r/w
Integer32
Size, in bytes, of ping packet to be sent out. If set to 0, the
default size for ping packet under the protocol chosen will be used.
If value given is to too large or too small, the biggest or smallest
possible packets will be used, respectively, and no errors will be
issued.
This object may not be modified if the associated a3ComPollReport
is equal to busy(2). When this object is successfully set,
a3ComPollReport will be set to idle(1).
Context
- MIB
- A3COM-SWITCHING-SYSTEMS-POLL-MIB
- OID
.1.3.6.1.4.1.43.29.4.22.1.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- a3ComPollEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-8191