ZYXEL-SFLOW-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
10
.1.3.6.1.4.1.890.1.15.3.75.1.3 · 1 row entry · 4 columns
The table contains sFlow collector configuration.
zyxelSflowCollectorEntry entry .1.3.6.1.4.1.890.1.15.3.75.1.3.1
An entry contains sFlow collector configuration.
Indexes
zySflowCollectorIpAddressType zySflowCollectorIpAddress
Column Syntax OID
zySflowCollectorIpAddressType
The Type of IP address for sflow collector entry.
INET-ADDRESS-MIBInetAddressType
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.890.1.15.3.75.1.3.1.1
zySflowCollectorIpAddress
The IP address of the sFlow collector.
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.890.1.15.3.75.1.3.1.2
zySflowCollectorUdpPort
Enter a UDP port number the Switch uses to send sFlow datagram to the collector.
If you change the port here, make sure you change it on the collector, too.
The default port is 6343.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.15.3.75.1.3.1.3
zySflowCollectorRowStatus
This object allow entry to be create and deleted a sFlow collector entry.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.15.3.75.1.3.1.4
.1.3.6.1.4.1.890.1.15.3.75.1.4 · 1 row entry · 1 columns
The table contains sFlow port configuration.
zyxelSflowPortEntry entry .1.3.6.1.4.1.890.1.15.3.75.1.4.1
An entry contains sFlow port configuration.
Indexes
BRIDGE-MIBdot1dBasePort
Column Syntax OID
zySflowPortState
Enable/Disable sflow on the port.
P-BRIDGE-MIBEnabledStatusr/w
Textual Convention: P-BRIDGE-MIBEnabledStatus Enumeration
Type Values:
1enabled
2disabled
.1.3.6.1.4.1.890.1.15.3.75.1.4.1.1
.1.3.6.1.4.1.890.1.15.3.75.1.6 · 1 row entry · 5 columns
The table contains sFlow port collector configuration.
zyxelSflowPortCollectorEntry entry .1.3.6.1.4.1.890.1.15.3.75.1.6.1
An entry contains sFlow port collector configuration.
Indexes
BRIDGE-MIBdot1dBasePort zySflowPortCollectorIpAddressType zySflowPortCollectorIpAddress
Column Syntax OID
zySflowPortCollectorIpAddressType
The Type of IP address for sflow port collector entry.
INET-ADDRESS-MIBInetAddressType
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.890.1.15.3.75.1.6.1.1
zySflowPortCollectorIpAddress
The IP address of the sFlow port collector.
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.890.1.15.3.75.1.6.1.2
zySflowPortCollectorSampleRate
Enter a number (N) from 256 to 65535.
The switch captures every one out of N packets for this port and creates sFlow datagram.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.15.3.75.1.6.1.3
zySflowPortCollectorPollInterval
Specify a time interval (from 20 to 120 in seconds) the switch waits before sending the sFlow datagram and packet counters for this port to the collector.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.15.3.75.1.6.1.4
zySflowPortCollectorRowStatus
This object allows a sFlow port collector entry to be created and deleted.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.15.3.75.1.6.1.5