XF-SOFTWARE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
31
.1.3.6.1.4.1.193.81.2.7.1.1 · 1 row entry · 8 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk xfSwLoadModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'XF-SOFTWARE-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-SOFTWARE-MIB::xfSwLoadModuleTable'
This table contains information about the load modules
that are part of the system releases as described by
the xfSwReleaseTable.
xfSwLoadModuleEntry row .1.3.6.1.4.1.193.81.2.7.1.1.1
Information about 1 software load module.
Column Syntax OID
There are two software releases present on the node:
- an active release, normally the most recent release
and the one that is running
- a passive release, that is the previous release or
the one that is currently b…
XfSwRelease
Type Constraints:
range: 1..2
Description:
Indication of one of the two software releases.
.1.3.6.1.4.1.193.81.2.7.1.1.1.1
Unique value within one release for each load module.
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.193.81.2.7.1.1.1.2
Product number of the load module. Normally something
like 'CAXR102_012/1'.
XF-TOP-MIBXfProductnumber
Type Constraints:
range: 0..30
Description:
A string indicating the product number
like 'RORJ605 001/1'. The string must be compliant to
standard Ericsson format for product numbers.
.1.3.6.1.4.1.193.81.2.7.1.1.1.3
Revision of the load module. Normally something like
'R1A'.
XF-TOP-MIBXfProductRevision
Type Constraints:
range: 0..40
Description:
String indicating a product revision like 'R1A00'.
The string must comply to standard Ericsson product
revision numbers.
.1.3.6.1.4.1.193.81.2.7.1.1.1.4
Indicates the status of the software upgrade process
for this load module.
passive(1)
the load module is not involved in a upgrade
process and is not active. I.e.it is part of
the previous software release.
Enumeration
Enumerated Values:
1passive
2upgradeStarted
3upgradeFinished
4upgradeFailed
5upgradeAborted
.1.3.6.1.4.1.193.81.2.7.1.1.1.5
The objects specifies the cause of a software upgrade
failure for this load module.
Enumeration
Enumerated Values:
1downloadFailure
2programFailure
3noFailure
.1.3.6.1.4.1.193.81.2.7.1.1.1.6
This object indicates the progress in downloading
the respective load module when part of an upgrade
of an NE to a software baseline.
percentInteger32
Constraints:
range: 0-100
.1.3.6.1.4.1.193.81.2.7.1.1.1.8
This object indicates a textual
description of the load module, indicating PIU type
as stated by the entPhysicalDescription MO.
SNMP-FRAMEWORK-MIBSnmpAdminString
Constraints:
range: 0-30
.1.3.6.1.4.1.193.81.2.7.1.1.1.9
.1.3.6.1.4.1.193.81.2.7.1.2 · 1 row entry · 6 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk xfSwReleaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'XF-SOFTWARE-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-SOFTWARE-MIB::xfSwReleaseTable'
This contains the information on the active and passive
software releases.
xfSwReleaseEntry row .1.3.6.1.4.1.193.81.2.7.1.2.1
Information about a software release. There are always
only two releases. For the active release write is
possible but will have no impact and will result in a
inconsistentValue error response.
Column Syntax OID
Indicates the Release the info for which this row is
applicable.
XfSwRelease
Type Constraints:
range: 1..2
Description:
Indication of one of the two software releases.
.1.3.6.1.4.1.193.81.2.7.1.2.1.1
Product number of the installed software package in
this release. Normally something like 'CAXR102 012/1'.
For the active release this is a read-only object.
XF-TOP-MIBXfProductnumberr/w
Type Constraints:
range: 0..30
Description:
A string indicating the product number
like 'RORJ605 001/1'. The string must be compliant to
standard Ericsson format for product numbers.
.1.3.6.1.4.1.193.81.2.7.1.2.1.2
Revision of the installed software package in this
Release. Normally something like 'R1A'.
For the active release this is a read-only object.
XF-TOP-MIBXfProductRevisionr/w
Type Constraints:
range: 0..40
Description:
String indicating a product revision like 'R1A00'.
The string must comply to standard Ericsson product
revision numbers.
.1.3.6.1.4.1.193.81.2.7.1.2.1.3
Indicates the desired status for this release. To start
a software upgrade the manager has to set
xfSwReleaseProductNumber and xfSwReleaseRevision. After
that it will set this object to upgradeStarted. Which
will lead t…
Enumerationr/w
Enumerated Values:
1upgradeStarted
2upgradeAborted
5activeAndRunning
6upgradeTest
.1.3.6.1.4.1.193.81.2.7.1.2.1.4
Indicates the status of this release.
passive(1)
release not involved in upgrade and currently not
running.

upgradeStarted(2)
the release is in the process of being upgraded

upgradeFi…
Enumeration
Enumerated Values:
1passive
2upgradeStarted
3upgradeFinished
4testing
5upgradeFailed
6upgradeAborted
7running
8testingFromManual
50errorInternal
51errorFileStorage
52ftpPingFailed
53ftpNoAccess
54ftpConnectionDetailsMissing
55ftpConnectionDetailsInvalid
56ftpConnectionTimeout
57ftpNoSuchRemoteFile
58ftpNoSuchRemoteDir
421ftpServiceNotAvailable
425ftpUnableToOpenDataConnection
426ftpConnectionClosed
450ftpFileBusy
451ftpLocalError
452ftpInsufficientStorageSpace
501ftpSyntaxError
502ftpCommandNotImplemented
503ftpBadSequenceCommands
504ftpParameterNotImplemented
530ftpNoLoggedIn
532ftpNeedAccount
550ftpFileUnavailable
552ftpExceededStorageAllocation
553ftpFileNameNotAllowed
.1.3.6.1.4.1.193.81.2.7.1.2.1.5
This object indicates whether the SBL information in
the SBDF is generated by Ericsson or by an operator.
This is based on a check of the SBDF.
Of course this will only be a reliable object when the
software can disting…
Enumeration
Enumerated Values:
1definedByEricsson
2definedByOperator
.1.3.6.1.4.1.193.81.2.7.1.2.1.6
.1.3.6.1.4.1.193.81.2.7.1.6 · 1 row entry · 9 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk xfSwBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'XF-SOFTWARE-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-SOFTWARE-MIB::xfSwBoardTable'
This table holds the information about software present
on the boards in the XF-NE. Boards without software will
not be in this table.
xfSwBoardEntry row .1.3.6.1.4.1.193.81.2.7.1.6.1
Entry in the table.
Column Syntax OID
Index to the load module on the board. A board may
contain more than one load module.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.193.81.2.7.1.6.1.1
This object indicates of what type the software is,
like DP (Device Processor) or FPGA (Field Programmable
Gate Array) or another type. New type can be defined by
defining a new OID in a other MIB.
ObjectIdentifier .1.3.6.1.4.1.193.81.2.7.1.6.1.2
This is a string indicating the product number of the
software in the active flash memory.
XF-TOP-MIBXfProductnumber
Type Constraints:
range: 0..30
Description:
A string indicating the product number
like 'RORJ605 001/1'. The string must be compliant to
standard Ericsson format for product numbers.
.1.3.6.1.4.1.193.81.2.7.1.6.1.3
This is a string indicating the revision of the
software in the active flash memory.
XF-TOP-MIBXfProductRevision
Type Constraints:
range: 0..40
Description:
String indicating a product revision like 'R1A00'.
The string must comply to standard Ericsson product
revision numbers.
.1.3.6.1.4.1.193.81.2.7.1.6.1.4
Indicates the status of the software on the board:
Unknown(1)
The status of the software is unknown for example
at startup.

Active(2)
Software on the board is OK and running

Upgrading…
Enumeration
Enumerated Values:
1unknown
2active
3upgrading
4wrongSoftware
5minSoftwareRevision
.1.3.6.1.4.1.193.81.2.7.1.6.1.5
This object indicates the progress of the software
upgrade process for each individual PIU. This indicates
both flash erasing and programming.
This object indicates this for both upgrade to a
baseline as well as for ins…
percentInteger32
Constraints:
range: 0-100
.1.3.6.1.4.1.193.81.2.7.1.6.1.6
This is a string indicating the product number of the
minimally acceptable software revision for this unit
type/variant.
XF-TOP-MIBXfProductnumber
Type Constraints:
range: 0..30
Description:
A string indicating the product number
like 'RORJ605 001/1'. The string must be compliant to
standard Ericsson format for product numbers.
.1.3.6.1.4.1.193.81.2.7.1.6.1.7
This is a string indicating the revision of the
minimally acceptable software revision for this unit
type/variant.
XF-TOP-MIBXfProductRevision
Type Constraints:
range: 0..40
Description:
String indicating a product revision like 'R1A00'.
The string must comply to standard Ericsson product
revision numbers.
.1.3.6.1.4.1.193.81.2.7.1.6.1.8
This object indicates that software upgrade of this
load module on this unit might lead to traffic
disturbance. This could for example happen in the
exceptional case where the load module includes FPGA
code for the traf…
Enumeration
Enumerated Values:
1unknown
2disturbing
3notDisturbing
.1.3.6.1.4.1.193.81.2.7.1.6.1.9
.1.3.6.1.4.1.193.81.2.7.1.10 · 1 row entry · 8 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk xfSwLmUpgradeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'XF-SOFTWARE-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-SOFTWARE-MIB::xfSwLmUpgradeTable'
This table is used to upgrade a single load module. For
each known load module an entry is present.
xfSwLmUpgradeEntry row .1.3.6.1.4.1.193.81.2.7.1.10.1
Entry in the table.
Column Syntax OID
Objects used to index the table.
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.193.81.2.7.1.10.1.1
Product number of the load module. Normally something
like 'CAXR102_012/1'.
XF-TOP-MIBXfProductnumber
Type Constraints:
range: 0..30
Description:
A string indicating the product number
like 'RORJ605 001/1'. The string must be compliant to
standard Ericsson format for product numbers.
.1.3.6.1.4.1.193.81.2.7.1.10.1.3
Revision to which the load module should be upgraded.
Normally something like 'R1A'.
XF-TOP-MIBXfProductRevisionr/w
Type Constraints:
range: 0..40
Description:
String indicating a product revision like 'R1A00'.
The string must comply to standard Ericsson product
revision numbers.
.1.3.6.1.4.1.193.81.2.7.1.10.1.4
Indicates the desired status for this release. To start
a software upgrade the manager has to set
xfSwLmUpgradeRevision. After that it will set this
object to upgradeStarted. Which will lead to downloading
the SBDF-file…
Enumerationr/w
Enumerated Values:
1upgradeStarted
2upgradeAborted
3activeAndRunning
4upgradeTest
.1.3.6.1.4.1.193.81.2.7.1.10.1.6
Indicates the status of the software upgrade process
for this load module.
active(1)
the load module is active and running on the PIU.

upgradeStarted(2)
a load module will have this status directly
Enumeration
Enumerated Values:
1active
2upgradeStarted
3upgradeFinished
4upgradeTested
5upgradeFailed
6upgradeAborted
50errorInternalError
51errorFileStorage
52ftpPingFailed
53ftpNoAccess
54ftpConnectionDetailsMissing
55ftpConnectionDetailsInvalid
56ftpConnectionTimeout
57ftpNoSuchRemoteFile
58ftpNoSuchRemoteDir
421ftpServiceNotAvailable
425ftpUnableToOpenDataConnection
426ftpConnectionClosed
450ftpFileBusy
451ftpLocalError
452ftpInsufficienStorageSpace
501ftpSyntaxError
502ftpCommandNotImplemented
503ftpBadSequenceCommands
504ftpParameterNotImplemented
530ftpNotLoggedIn
532ftpNeedAccount
550ftpFileUnavailable
552ftpExceededStorageAllocation
553ftpFileNameNotAllowed
.1.3.6.1.4.1.193.81.2.7.1.10.1.7
This object indicates the progress in downloading
the respective load module when part of an upgrade of
an inserted PIU.
percentInteger32
Constraints:
range: 0-100
.1.3.6.1.4.1.193.81.2.7.1.10.1.8
This object specifies the cause of a software
upgrade failure.
Enumeration
Enumerated Values:
1downloadFailure
2programFailure
3noFailure
.1.3.6.1.4.1.193.81.2.7.1.10.1.9
This object indicates a textual
description of the load module, indicating PIU type
as stated by the entPhysicalDescription MO.
SNMP-FRAMEWORK-MIBSnmpAdminString
Constraints:
range: 0-30
.1.3.6.1.4.1.193.81.2.7.1.10.1.10