WebGraph-Thermometer-PT-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
23
Rows
23
Columns
154
.1.3.6.1.4.1.5040.1.2.39.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSensorTable'
List of sensors.
Temperature sensor numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSensorNomandatory
Temperature sensor number.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.5040.1.2.39.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.39.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtTempValueTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtTempValuemandatory
Temperature value of the sensor, ASCII, 5 characters in length.
|
OctetString Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.39.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.39.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtBinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtBinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
Binary temperature values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtBinaryTempValuemandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an invalid measured value. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.39.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.39.1.8
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtTempValuePktTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtTempValuePktTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtTempValuePktmandatory
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
|
OctetString Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.39.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.39.3.1.4.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSensorColorTable'
List of sensor colors for the praphical presentation.
Index numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSensorColormandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.39.3.1.4.4.1.1 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtAlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtAlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtAlarmNomandatory
Alarm number.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3
·
1 row entry
·
44 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtAlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtAlarmTriggermandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0 : Timer Bit 1 : ColdStart Bit 2 : WarmStart Bit 3 : Sensor lost Bit 4-7: unused Octet 4: Bit 0 : Sensor 1 Bit 1… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.1 |
|
wtWebioAn1GraphPtAlarmMinmandatory
Minimum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.2 |
|
wtWebioAn1GraphPtAlarmMaxmandatory
Maximum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.3 |
|
wtWebioAn1GraphPtAlarmHysteresismandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.4 |
|
wtWebioAn1GraphPtAlarmDelaymandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.5 |
|
wtWebioAn1GraphPtAlarmIntervalmandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.6 |
|
wtWebioAn1GraphPtAlarmEnablemandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Mail Enable Bit 1 : SNMP Trap enable Bit 2 : TCP Client enable Bit 3 : Syslog Messages enable Bit 4 : FTP enable Bi… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.7 |
|
wtWebioAn1GraphPtAlarmEMailAddrmandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.8 |
|
wtWebioAn1GraphPtAlarmMailSubjectmandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.9 |
|
wtWebioAn1GraphPtAlarmMailTextmandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.10 |
|
wtWebioAn1GraphPtAlarmManagerIPmandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.11 |
|
wtWebioAn1GraphPtAlarmTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.12 |
|
wtWebioAn1GraphPtAlarmMailOptionsmandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.13 |
|
wtWebioAn1GraphPtAlarmTcpIpAddrmandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.14 |
|
wtWebioAn1GraphPtAlarmTcpPortmandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.15 |
|
wtWebioAn1GraphPtAlarmTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.16 |
|
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.17 |
|
wtWebioAn1GraphPtAlarmClearMailTextmandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.18 |
|
wtWebioAn1GraphPtAlarmClearTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.19 |
|
wtWebioAn1GraphPtAlarmClearTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.20 |
|
wtWebioAn1GraphPtAlarmSyslogIpAddrmandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.21 |
|
wtWebioAn1GraphPtAlarmSyslogPortmandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.22 |
|
wtWebioAn1GraphPtAlarmSyslogTextmandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.23 |
|
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.24 |
|
wtWebioAn1GraphPtAlarmFtpDataPortmandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.25 |
|
wtWebioAn1GraphPtAlarmFtpFileNamemandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.26 |
|
wtWebioAn1GraphPtAlarmFtpTextmandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.27 |
|
wtWebioAn1GraphPtAlarmFtpClearTextmandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.28 |
|
wtWebioAn1GraphPtAlarmFtpOptionmandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.29 |
|
wtWebioAn1GraphPtAlarmTimerCronmandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.30 |
|
wtWebioAn1GraphPtAlarmDeltaTempmandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.31 |
|
wtWebioAn1GraphPtAlarmNamemandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.39 |
|
wtWebioAn1GraphPtAlarmActivemandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.40 |
|
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.61 |
|
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.62 |
|
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.63 |
|
wtWebioAn1GraphPtAlarmHttpReqSetUrlmandatory
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.64 |
|
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.65 |
|
HTTP Request: Server Port
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.66 |
|
wtWebioAn1GraphPtAlarmMqttTopicPathmandatory
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.67 |
|
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.68 |
|
wtWebioAn1GraphPtAlarmMqttTopicClearmandatory
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.69 |
|
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.70 |
|
wtWebioAn1GraphPtAlarmLimitWindowmandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.5.3.1.71 |
.1.3.6.1.4.1.5040.1.2.39.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPt2SensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPt2SensorColorTable'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.39.3.1.6.2.3.1.1 |
|
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.39.3.2.1
·
1 row entry
·
8 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtPortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtPortNamemandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.1 |
|
wtWebioAn1GraphPtPortTextmandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.2 |
|
wtWebioAn1GraphPtPortOffset1mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.3 |
|
wtWebioAn1GraphPtPortTemperature1mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.4 |
|
wtWebioAn1GraphPtPortOffset2mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.5 |
|
wtWebioAn1GraphPtPortTemperature2mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.6 |
|
wtWebioAn1GraphPtPortCommentmandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.39.3.2.1.1.7 |
|
wtWebioAn1GraphPtPortSensorSelectmandatory
Binary coded options of the sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 (default) Bit 1 : PT1000 Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.39.3.2.1.1.8 |
.1.3.6.1.4.1.5040.1.2.40.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwSensorTable'
List of sensors.
Temperature sensor numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwSensorNomandatory
Temperature sensor number.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.5040.1.2.40.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.40.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwTempValueTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwTempValuemandatory
Temperature value of the sensor, ASCII, 5 characters in length.
|
OctetString Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.40.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.40.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwBinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwBinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
Binary temperature values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwBinaryTempValuemandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an invalid measured value. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.40.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.40.1.6
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwOutputTable'
List of outputs.
Output numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwOutputNomandatory
Output number.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.5040.1.2.40.1.6.1.1 |
.1.3.6.1.4.1.5040.1.2.40.1.7
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwBinaryOutputValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwBinaryOutputValueTable'
List of binary ouput values corresponding to the channel numbers.
Binary states of the outputs.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wtWebioAn1GraphPtSwBinaryOutputValuemandatory
Binary state of the output.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.5040.1.2.40.1.7.1.1 |
.1.3.6.1.4.1.5040.1.2.40.1.8
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwTempValuePktTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwTempValuePktTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwTempValuePktmandatory
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
|
OctetString Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.40.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.40.3.1.4.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwSensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwSensorColorTable'
List of sensor colors for the praphical presentation.
Index numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwSensorColormandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.40.3.1.4.4.1.1 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwAlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwAlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwAlarmNomandatory
Alarm number.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3
·
1 row entry
·
44 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwAlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwAlarmTriggermandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0 : Timer Bit 1 : ColdStart Bit 2 : WarmStart Bit 3 : Sensor lost Bit 4-7: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.1 |
|
wtWebioAn1GraphPtSwAlarmMinmandatory
Minimum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.2 |
|
wtWebioAn1GraphPtSwAlarmMaxmandatory
Maximum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.3 |
|
wtWebioAn1GraphPtSwAlarmHysteresismandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.4 |
|
wtWebioAn1GraphPtSwAlarmDelaymandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.5 |
|
wtWebioAn1GraphPtSwAlarmIntervalmandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.6 |
|
wtWebioAn1GraphPtSwAlarmEnablemandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Output switch enable Bit 1 : Mail Enable Bit 2 : SNMP Trap enable Bit 3 : TCP Client enable Bit 4 : Syslog Messages … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.7 |
|
wtWebioAn1GraphPtSwAlarmEMailAddrmandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.8 |
|
wtWebioAn1GraphPtSwAlarmMailSubjectmandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.9 |
|
wtWebioAn1GraphPtSwAlarmMailTextmandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.10 |
|
wtWebioAn1GraphPtSwAlarmManagerIPmandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.11 |
|
wtWebioAn1GraphPtSwAlarmTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.12 |
|
wtWebioAn1GraphPtSwAlarmMailOptionsmandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.13 |
|
wtWebioAn1GraphPtSwAlarmTcpIpAddrmandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.14 |
|
wtWebioAn1GraphPtSwAlarmTcpPortmandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.15 |
|
wtWebioAn1GraphPtSwAlarmTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.16 |
|
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.17 |
|
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.18 |
|
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.19 |
|
wtWebioAn1GraphPtSwAlarmClearTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.20 |
|
wtWebioAn1GraphPtSwAlarmSyslogIpAddrmandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.21 |
|
wtWebioAn1GraphPtSwAlarmSyslogPortmandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.22 |
|
wtWebioAn1GraphPtSwAlarmSyslogTextmandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.23 |
|
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.24 |
|
wtWebioAn1GraphPtSwAlarmFtpDataPortmandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.25 |
|
wtWebioAn1GraphPtSwAlarmFtpFileNamemandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.26 |
|
wtWebioAn1GraphPtSwAlarmFtpTextmandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.27 |
|
wtWebioAn1GraphPtSwAlarmFtpClearTextmandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.28 |
|
wtWebioAn1GraphPtSwAlarmFtpOptionsmandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.29 |
|
wtWebioAn1GraphPtSwAlarmTimerCronmandatory
This entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Rang… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.30 |
|
wtWebioAn1GraphPtSwAlarmDeltaTempmandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.31 |
|
wtWebioAn1GraphPtSwAlarmNamemandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.39 |
|
wtWebioAn1GraphPtSwAlarmActivemandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.40 |
|
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.61 |
|
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.62 |
|
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.63 |
|
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.64 |
|
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.65 |
|
HTTP Request: Server Port
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.66 |
|
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.67 |
|
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.68 |
|
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.69 |
|
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.70 |
|
wtWebioAn1GraphPtSwAlarmLimitWindowmandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.5.3.1.71 |
.1.3.6.1.4.1.5040.1.2.40.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSw2SensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSw2SensorColorTable'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.40.3.1.6.2.3.1.1 |
|
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwReportIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwReportIfTable'
List of Report indices.
Numbers of the Reports.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwReportNomandatory
Report number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.2.1.1 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3
·
1 row entry
·
25 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwReportTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwReportTable'
List of settings depending on the Report number.
Report parameters of the individual Reports.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwReportEnablemandatory
Bin?r kodierte Triggerbedingungen:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Report enable Bit 1-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.1 |
|
wtWebioAn1GraphPtSwReportTimerCronmandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.2 |
|
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.3 |
|
wtWebioAn1GraphPtSwReportEMailAddrmandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.8 |
|
wtWebioAn1GraphPtSwReportMailSubjectmandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.9 |
|
wtWebioAn1GraphPtSwReportMailTextmandatory
Report mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.10 |
|
wtWebioAn1GraphPtSwReportManagerIPmandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.11 |
|
wtWebioAn1GraphPtSwReportTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.12 |
|
wtWebioAn1GraphPtSwReportMailOptionsmandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Logger.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.13 |
|
wtWebioAn1GraphPtSwReportTcpIpAddrmandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.14 |
|
wtWebioAn1GraphPtSwReportTcpPortmandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.15 |
|
wtWebioAn1GraphPtSwReportTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.16 |
|
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.17 |
|
Report clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.18 |
|
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.19 |
|
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.20 |
|
IP address of the syslog server to which the Webio device should send syslog messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.24 |
|
wtWebioAn1GraphPtSwReportSyslogPortmandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.25 |
|
wtWebioAn1GraphPtSwReportSyslogTextmandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.26 |
|
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.27 |
|
wtWebioAn1GraphPtSwReportFtpDataPortmandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.28 |
|
wtWebioAn1GraphPtSwReportFtpFileNamemandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.29 |
|
wtWebioAn1GraphPtSwReportFtpTextmandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.30 |
|
Report clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.31 |
|
wtWebioAn1GraphPtSwReportFtpOptionmandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.1.7.3.1.32 |
.1.3.6.1.4.1.5040.1.2.40.3.2.1
·
1 row entry
·
9 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwPortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwPortNamemandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.1 |
|
wtWebioAn1GraphPtSwPortTextmandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.2 |
|
wtWebioAn1GraphPtSwPortOffset1mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.3 |
|
wtWebioAn1GraphPtSwPortTemperature1mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.4 |
|
wtWebioAn1GraphPtSwPortOffset2mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.5 |
|
wtWebioAn1GraphPtSwPortTemperature2mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.6 |
|
wtWebioAn1GraphPtSwPortCommentmandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.1.1.7 |
|
wtWebioAn1GraphPtSwPortSensorSelectmandatory
Binary coded options of the sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 (default) Bit 1 : PT1000 Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.2.1.1.8 |
|
wtWebioAn1GraphPtSwPortSensorUnitmandatory
Binary coded options of the sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Celsius (default) Bit 1 : Fahrenheit Bit 2 : Kelvin Bit 3-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.2.1.1.9 |
.1.3.6.1.4.1.5040.1.2.40.3.2.3
·
1 row entry
·
5 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn1GraphPtSwPortOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Thermometer-PT-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Thermometer-PT-US-MIB::wtWebioAn1GraphPtSwPortOutputTable'
List of settings depending on the sensor number.
Parameters for the individual outputs.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebioAn1GraphPtSwPortOutputNamemandatory
Name of the output.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.3.1.1 |
|
wtWebioAn1GraphPtSwPortOutputTextmandatory
Description of the output.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.3.1.2 |
|
Binary coded options of the output:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Normally open (default) Bit 1 : Normally closed Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.2.3.1.3 |
|
wtWebioAn1GraphPtSwPortOutputCommentmandatory
Additional informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.40.3.2.3.1.4 |
|
wtWebioAn1GraphPortOutputResetEnablemandatory
Binary coded options of the output:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Manual Reset enable (default off) Bit 1-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.40.3.2.3.1.5 |