WebGraph-AnalogIO-57762-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
10
Rows
10
Columns
100
.1.3.6.1.4.1.5040.1.2.29.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762SensorTable'
List of sensors.
List of sensor numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762SensorNomandatory
Sensor number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.29.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762ValuesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762ValuesTable'
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762Valuesmandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.29.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762BinaryValuesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762BinaryValuesTable'
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762BinaryValuesmandatory
Binary measurement value of the sensor in 1/1000,
signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.8
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762ValuesPointTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762ValuesPointTable'
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762ValuesPointmandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.29.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762BinaryIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762BinaryIfTable'
Table of indices.
Indices of the binary channels.
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762BinaryModeNomandatory
Number of the binary channel.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3
·
1 row entry
·
29 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762BinaryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762BinaryTable'
Table of properties of the binary mode.
Binary properties.
| Column | Syntax | OID |
|---|---|---|
|
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.1 |
|
Local TCP port for data exchange in this server mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.2 |
|
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.3 |
|
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box S… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.4 |
|
Local TCP port for data exchange in this client mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.5 |
|
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.6 |
|
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.7 |
|
Building a connection may be protected by the
administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.8 |
|
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.9 |
|
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.10 |
|
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.11 |
|
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.12 |
|
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.13 |
|
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.14 |
|
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.15 |
|
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.16 |
|
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.17 |
|
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.18 |
|
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.19 |
|
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. |
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.20 |
|
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port. Not used at mode Compatible 50xxx. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.21 |
|
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.22 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.24 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.25 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.26 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.27 |
|
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.28 |
|
Building a connection may be protected by a specific
user name within the server. Enter the user name to establish the connection, if a user name entry exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.29 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762AlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762AlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762AlarmNomandatory
Alarm number.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3
·
1 row entry
·
49 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762AlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762AlarmTriggermandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.1 |
|
wtWebGraphAnalog57762AlarmMin1mandatory
Minimum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.2 |
|
wtWebGraphAnalog57762AlarmMax1mandatory
Maximum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.3 |
|
Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
with maximum 3 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.4 |
|
wtWebGraphAnalog57762AlarmDelaymandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.5 |
|
wtWebGraphAnalog57762AlarmIntervalmandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.6 |
|
wtWebGraphAnalog57762AlarmEnablemandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.7 |
|
wtWebGraphAnalog57762AlarmEMailAddrmandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.8 |
|
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.9 |
|
wtWebGraphAnalog57762AlarmMailTextmandatory
Alarm mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.10 |
|
wtWebGraphAnalog57762AlarmManagerIPmandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.11 |
|
wtWebGraphAnalog57762AlarmTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.12 |
|
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.13 |
|
wtWebGraphAnalog57762AlarmTcpIpAddrmandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.14 |
|
wtWebGraphAnalog57762AlarmTcpPortmandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.15 |
|
wtWebGraphAnalog57762AlarmTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.16 |
|
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.17 |
|
Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.18 |
|
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.19 |
|
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.20 |
|
wtWebGraphAnalog57762AlarmMin2mandatory
Minimum sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.21 |
|
wtWebGraphAnalog57762AlarmMax2mandatory
Maximum sensor 2 with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.22 |
|
Hysterese rel. sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.23 |
|
IP address of the syslog server to which the Webio device should send syslog messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.24 |
|
wtWebGraphAnalog57762AlarmSyslogPortmandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.25 |
|
wtWebGraphAnalog57762AlarmSyslogTextmandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.26 |
|
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.27 |
|
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.28 |
|
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.29 |
|
wtWebGraphAnalog57762AlarmFtpTextmandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.30 |
|
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.31 |
|
wtWebGraphAnalog57762AlarmFtpOptionmandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.32 |
|
wtWebGraphAnalog57762AlarmTimerCronmandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.33 |
|
wtWebGraphAnalog57762AlarmNamemandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.39 |
|
wtWebGraphAnalog57762AlarmActivemandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.40 |
|
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.61 |
|
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.62 |
|
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.63 |
|
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.64 |
|
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.65 |
|
HTTP Request: Server Port
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.66 |
|
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.67 |
|
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.68 |
|
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.69 |
|
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.70 |
|
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.71 |
|
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.76 |
|
wtWebGraphAnalog57762AlarmMqttQoSmandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.77 |
|
wtWebGraphAnalog57762AlarmMqttRetainmandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.78 |
.1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762SensorColor2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762SensorColor2Table'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.1 |
|
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1
·
1 row entry
·
14 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57762PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57762-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57762-US-MIB::wtWebGraphAnalog57762PortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57762PortNamemandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.1 |
|
wtWebGraphAnalog57762PortTextmandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.2 |
|
wtWebGraphAnalog57762PortOffset1mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.3 |
|
wtWebGraphAnalog57762SetPoint1mandatory
Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.4 |
|
wtWebGraphAnalog57762PortOffset2mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.5 |
|
wtWebGraphAnalog57762SetPoint2mandatory
Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.6 |
|
wtWebGraphAnalog57762PortCommentmandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.7 |
|
Binary coded options for sensor 1:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.8 |
|
wtWebGraphAnalog57762PortUnitmandatory
User scale: displayed unit.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.9 |
|
wtWebGraphAnalog57762PortScale0mandatory
User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.10 |
|
wtWebGraphAnalog57762PortScale100mandatory
User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.11 |
|
wtWebGraphAnalog57762PortOutputModemandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57762PortInputMode will be set automat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.12 |
|
wtWebGraphAnalog57762PortInputModemandatory
This binary coded input mode defines the individual operation mode for any
input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57762PortOutputMode will be set automatic… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1.1.13 |
|
wtWebGraphAnalog57762PortPresetValuemandatory
This value will be set after reset or initialisation.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.16 |