WISI-GTSENSORS-MIB
Monitored by Observium This MIB module represents the various sensors that are
installed in a system or standalone unit, such as temperature
sensors, power supply voltage/current measurements and fan RPM
sensors.
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
- Source file
WISI-GTSENSORS-MIB- Last revised
- Identity
gtSensorsMIB- Base OID
1.3.6.1.4.1.7465.20.2.9.1.3
Imported Objects
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DisplayString |
| WISI-GTMODULES-MIB | gtModule |
| WISI-TANGRAM-MIB | gtUnit |
Net-SNMP examples using the wisi MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'WISI-GTSENSORS-MIB' -M '/opt/observium/mibs/wisi:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'WISI-GTSENSORS-MIB::gtSensorsMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WISI-GTSENSORS-MIB' -M '/opt/observium/mibs/wisi:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WISI-GTSENSORS-MIB::gtSensorsMIB'
Objects (32)
11 directly used by Observium
Showing 32 of 32 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.7465.20.2.9.1.3 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.0 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.1 |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.2 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.1 |
|
|
|
OctetString
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.2 |
|
|
'CInteger32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.3 |
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.3 |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.1 |
|
|
|
OctetString
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.2 |
|
rpmUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.3 |
|
|
|
rpmUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.4 |
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.5 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.6 |
||
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.5 |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.1 |
|
|
|
OctetString
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.2 |
|
|
mWUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.3 |
|
|
mAUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.4 |
|
|
mVUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.5 |
|
|
mVUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.6 |
|
|
mVUnsigned32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.7 |
|
|
'CInteger32
|
.1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.8 |
.1.3.6.1.4.1.7465.20.2.9.1.3.2 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.2.1 |
||
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2 |
Dependencies (6) 5 direct · 1 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- WISI-ROOT-MIBwisi
- WISI-TANGRAM-MIBwisi
- WISI-GTMODULES-MIBwisi
- WISI-GTSENSORS-MIBwisiselected
Conformance Groups (6)
|
gtTempName gtTempValue gtFanName gtFanControl gtFanSpeed gtPSUName gtPSUPower gtPSUCurrent gtPSUVoltageInt gtPSUVoltageOR gtPSUVoltageExt gtPSUTemperature
The gtSensorsV1Group group is mandatory only for those
GTSENSORSv2 entities which also implement GTSENSORSv1. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.1
|
|
|
gtTempName gtTempValue gtFanName gtFanSpeed gtPSUName gtPSUPower gtPSUCurrent gtPSUVoltageInt gtPSUVoltageOR gtPSUVoltageExt gtPSUTemperature
The gtSensorsSystemGroup group defines GTSENSORSv2 entities
which are mandatory. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.2
|
|
|
The gtSensorsStatsGroup group defines GTSENSORSv2 entities
which provide statistical information. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.3
|
|
|
The gtSensorsTrapGroup group defines GTSENSORSv2 trap objects
which are mandatory. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.4
|
|
|
The gtSensorsSetGroup group defines GTSENSORSv2 entities
which can be set the manager. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.5
|
|
|
gtSensorsNotifyFanPlugin gtSensorsNotifyFanPlugout gtSensorsNotifyPSUPlugin gtSensorsNotifyPSUPlugout gtSensorsNotifyTemperature gtSensorsNotifyFanSpeed gtSensorsNotifyPSUCurrent gtSensorsNotifyPSUVoltage gtSensorsNotifyPSUTemperature
The gtSensorsBasicNotificationsGroup group defines
GTSENSORSv2 notification objects which are mandatory. |
.1.3.6.1.4.1.7465.20.2.9.1.3.2.2.6
|
Compliance Statements (1)
OID
.1.3.6.1.4.1.7465.20.2.9.1.3.2.1.1The compliance statement for GTSENSORSv2 entities
which implement the GTSENSORSv2 MIB.
which implement the GTSENSORSv2 MIB.
Required groups
| mandatory | gtSensorsV1Group | |
| mandatory | gtSensorsSystemGroup | |
| mandatory | gtSensorsStatsGroup | |
| mandatory | gtSensorsTrapGroup | |
| mandatory | gtSensorsSetGroup | |
| mandatory | gtSensorsBasicNotificationsGroup |
Notifications / Traps (13)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.1 |
The gtSensorsNotifyFanPlugin notification indicates that
a new fan unit has been plugged-in. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.10 |
The gtSensorsNotifyPSUTempHighClear notification indicates that
a PSU (Power Supply Unit) temperature has decreased below upper limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.11 |
The gtSensorsNotifyBOARDTempHighClear notification indicates that
temperature on GT11 board has decreased below upper limit |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.12 |
The gtSensorsNotifyPSUFailure notification indicates that
a PSU (Power Supply Unit) internal voltage dropped below limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.13 |
The gtSensorsNotifyPSUFailureClear notification indicates that
a PSU (Power Supply Unit) internal voltage has increased above lower limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.2 |
The gtSensorsNotifyFanPlugout notification indicates that
a fan unit has been plugged-out. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.3 |
The gtSensorsNotifyPSUPlugin notification indicates that
a new PSU (Power Supply Unit) has been plugged-in. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.4 |
The gtSensorsNotifyPSUPlugout notification indicates that
a PSU (Power Supply Unit) has been plugged-out. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.5 |
The gtSensorsNotifyTemperature notification indicates that
temperature on GT11 board is above upper limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.6 |
The gtSensorsNotifyFanSpeed notification indicates that
at least one of the fans RPM on fanbay is below lower limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.7 |
The gtSensorsNotifyPSUCurrent notification indicates that
a PSU (Power Supply Unit) output current is out of range limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.8 |
The gtSensorsNotifyPSUVoltage notification indicates that
a PSU (Power Supply Unit) output voltage is out of range limit. |
|
.1.3.6.1.4.1.7465.20.2.9.1.3.0.9 |
The gtSensorsNotifyPSUTemperature notification indicates that
a PSU (Power Supply Unit) temperature is above upper limit. |