WESTERMO-DDM-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
7
ddmPortTable
table.1.3.6.1.4.1.16177.2.2.1.1
·
1 row entry
·
7 columns
Uses the westermo variant from
Command help
/opt/observium/mibs/westermo.
Walk ddmPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WESTERMO-DDM-MIB' -M '/opt/observium/mibs/westermo:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WESTERMO-DDM-MIB::ddmPortTable'
Table containing DDM diagnostics per DDM capable SFP.
This row in the sfpDdmPortTable containing per port
SFP DDM diagnostics.
SFP DDM diagnostics.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
This index maps to the port's ifIndex in the ifTable.
|
IF-MIBInterfaceIndex Type Constraints: range: 1..2147483647Description: A unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must … |
.1.3.6.1.4.1.16177.2.2.1.1.1.1 |
|
The system name of the port.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.16177.2.2.1.1.1.2 |
|
The supply voltage of the SFP. The accuracy is better than +/-3 % and
the total range of 0 - 6550 mV. The voltage is represented in mV. |
Integer32 Constraints: range: 0-6550 |
.1.3.6.1.4.1.16177.2.2.1.1.1.3 |
|
Temperature of the SFP. The temperature accuracy is better
than 3 degrees Celsius and the total range of -128 degrees C to +128 degrees C. |
Integer32 Constraints: range: -128-128 |
.1.3.6.1.4.1.16177.2.2.1.1.1.4 |
|
The transmit bias current. The accuracy is better than +/- 10 % and
the total range of 0 - 131 mA. The current is represented in uA. |
Integer32 Constraints: range: 0-131 |
.1.3.6.1.4.1.16177.2.2.1.1.1.5 |
|
Transmit power of the laser. The accuracy is better than +/-3dB and
the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm. |
Integer32 Constraints: range: -4000-820 |
.1.3.6.1.4.1.16177.2.2.1.1.1.6 |
|
Receiving power of the laser. The accuracy is better than +/-3dB and
the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm. |
Integer32 Constraints: range: -4000-820 |
.1.3.6.1.4.1.16177.2.2.1.1.1.7 |