VMWARE-ENV-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
7
vmwEnvTable
table.1.3.6.1.4.1.6876.4.20.3
·
1 row entry
·
7 columns
Uses the vmware variant from
Command help
/opt/observium/mibs/vmware.
Walk vmwEnvTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VMWARE-ENV-MIB' -M '/opt/observium/mibs/vmware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VMWARE-ENV-MIB::vmwEnvTable'
This table is populated from monitoring IPMI BMC device. One conceptual row is maintained for each reporting component. This table may be cleared by operational request to BMC and normally is configured to stop adding new entries when full.
One entry for each physical component reporting its
status to ESX Operating System.
status to ESX Operating System.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This is the identifier as reported by the vendor hardware's BMC
as per Table 32 section 32.1 SEL Event Records [1]. On ESXi: the command: localcli hardware ipmi sel list can provide the listing of IPMI SEL entries as … |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.6876.4.20.3.1.1 |
||||||||||||||||||||
|
Hardware component reporting environmental state
|
VMWARE-TC-MIBVmwSubsystemTypes Type Values:
|
.1.3.6.1.4.1.6876.4.20.3.1.2 |
||||||||||||||||||||
|
Last reported state of this component
|
VMWARE-TC-MIBVmwSubsystemStatus Type Values:
|
.1.3.6.1.4.1.6876.4.20.3.1.3 |
||||||||||||||||||||
|
Human readable description of this event
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.6876.4.20.3.1.4 |
||||||||||||||||||||
|
Timestamp as reported from BMC for the SEL entry.
See CLI: 'localcli hardware ipmi sel list' for same report. Note that BMC maintains it own clock and may not be the same as the time ESX itself reports. On ESX: the CLI … |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.6876.4.20.3.1.5 |
||||||||||||||||||||
|
The Index into hrDeviceTable for the hardware related to this event.
Report 0 if this entry does not have a related entry in hrDeviceTable. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.6876.4.20.3.1.6 |
||||||||||||||||||||
|
This is the BMC reported Sensor Number byte 12 from SEL Event record
as per Table 32 section 32.1 SEL Event Records [1]. IPMI Sensors are reported in hrDeviceTable and vmwEnvTable provides the mapping to the specific en… |
Integer32 Constraints: range: 0-255 |