UBNT-EdgeMAX-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
6
Rows
6
Columns
32
ubntPowerOutTable
table.1.3.6.1.4.1.41112.1.5.2.2
·
1 row entry
·
4 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntPowerOutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntPowerOutTable'
A list of power out entries. The number of entries is given by the value of ubntPowerOutsCount.
An entry in the ubntPowerOutTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each power output.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.41112.1.5.2.2.1.1 |
|
Output voltage in mV.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.2.2.1.2 |
|
Output current in mA.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.2.2.1.3 |
|
Output power in mW.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.2.2.1.4 |
ubntPsuTable
table.1.3.6.1.4.1.41112.1.5.3.2
·
1 row entry
·
12 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntPsuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntPsuTable'
A list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber.
An entry in the ubntPsuTable.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PSU.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.41112.1.5.3.2.1.1 |
||||||||
|
PSU Type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.3.2.1.2 |
||||||||
|
PSU Status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.3.2.1.3 |
||||||||
|
PSU operational status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.3.2.1.4 |
||||||||
|
PSU voltage in mV.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.3.2.1.5 |
||||||||
|
PSU temperature in thousands of degrees Celsius.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.3.2.1.6 |
||||||||
|
Shows PSU charging state if it is supported.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.3.2.1.7 |
||||||||
|
Number of batteries connected to PSU.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.3.2.1.8 |
||||||||
|
Current battery charge level as a percent (0-100%).
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.41112.1.5.3.2.1.9 |
||||||||
|
The battery run time remaining before battery exhaustion.
|
SNMPv2-SMITimeTicks Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.41112.1.5.3.2.1.10 |
||||||||
|
Indicates whether the batteries need replacing.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.3.2.1.11 |
||||||||
|
Battery installation date (mm/dd/yyyy).
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.41112.1.5.3.2.1.12 |
ubntThermsTable
table.1.3.6.1.4.1.41112.1.5.4.2
·
1 row entry
·
3 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntThermsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntThermsTable'
A list of thermometers entries. The number of entries is given by the value of ubntThermometersCount.
An entry in the ubntThermsTable.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for thermometer.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.41112.1.5.4.2.1.1 |
||||||||
|
Type of thermometer.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.4.2.1.2 |
||||||||
|
Temperature in thousands of degrees Celsius.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.4.2.1.3 |
ubntFansTable
table.1.3.6.1.4.1.41112.1.5.5.2
·
1 row entry
·
3 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntFansTable'
A list of fan entries. The number of entries is given by the value of ubntFansCount.
An entry in the ubntFansTable.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for fan.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.41112.1.5.5.2.1.1 |
||||||||
|
Type of fan.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.41112.1.5.5.2.1.2 |
||||||||
|
Fan RPM.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.5.2.1.3 |
ubntSfpsTable
table.1.3.6.1.4.1.41112.1.5.7.2
·
1 row entry
·
7 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntSfpsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntSfpsTable'
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.7.2.1.1 |
|||||
| SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.41112.1.5.7.2.1.2 |
|||||
| SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.41112.1.5.7.2.1.3 |
|||||
| OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.41112.1.5.7.2.1.4 |
|||||
| OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.41112.1.5.7.2.1.5 |
|||||
| SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.41112.1.5.7.2.1.6 |
|||||
| SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.41112.1.5.7.2.1.7 |
ubntOnuPortsTable
table.1.3.6.1.4.1.41112.1.5.8.1
·
1 row entry
·
3 columns
Uses the ubiquiti variant from
Command help
/opt/observium/mibs/ubiquiti.
Walk ubntOnuPortsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UBNT-EdgeMAX-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UBNT-EdgeMAX-MIB::ubntOnuPortsTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
.1.3.6.1.4.1.41112.1.5.8.1.1.1 |
||
| SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.41112.1.5.8.1.1.2 |
|
|
in bits per second, see IF-MIB::ifSpeed
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.41112.1.5.8.1.1.3 |