TSL-MIB

Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Polling
Explore Observium network monitoring
Source file
TSL-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises Opaque
Objects (41)
1 directly used by Observium
.1.3.6.1.4.1.6853
.1.3.6.1.4.1.6853.2
alarmIdent mandatory
.1.3.6.1.4.1.6853.2.1
alarmTable mandatory
.1.3.6.1.4.1.6853.2.2
alarmEntry mandatory
.1.3.6.1.4.1.6853.2.2.1
alarmTableIndex mandatory
Integer32
.1.3.6.1.4.1.6853.2.2.1.1
alarmType mandatory
Enumeration
.1.3.6.1.4.1.6853.2.2.1.2
alarmIndex mandatory
.1.3.6.1.4.1.6853.2.2.1.3
alarmText mandatory r/w
.1.3.6.1.4.1.6853.2.2.1.4
alarmState mandatory
Enumeration
.1.3.6.1.4.1.6853.2.2.1.5
alarmPolarity mandatory r/w
Enumeration
.1.3.6.1.4.1.6853.2.2.1.6
alarmData optional
.1.3.6.1.4.1.6853.2.2.1.7
alarmTotal mandatory
.1.3.6.1.4.1.6853.2.3
alarmLocation mandatory r/w
.1.3.6.1.4.1.6853.2.4
alarmEqptTemp optional
.1.3.6.1.4.1.6853.2.5
alarmEqptTempHi optional r/w
.1.3.6.1.4.1.6853.2.6
.1.3.6.1.4.1.6853.3
mdu12Ident OBS ✓ mandatory
.1.3.6.1.4.1.6853.3.1
mduTotalCurrent mandatory r/w
.1.3.6.1.4.1.6853.3.10
mduCurrentLimit mandatory r/w
.1.3.6.1.4.1.6853.3.11
mduAuxRly1 mandatory r/w
Enumeration
.1.3.6.1.4.1.6853.3.12
mduAuxRly2 mandatory r/w
Enumeration
.1.3.6.1.4.1.6853.3.13
mduPowerOn mandatory r/w
Enumeration
.1.3.6.1.4.1.6853.3.2
mduSeqDelay mandatory r/w
.1.3.6.1.4.1.6853.3.3
mduOutputTable mandatory
.1.3.6.1.4.1.6853.3.4
mduOutputEntry mandatory
.1.3.6.1.4.1.6853.3.4.1
mduOutputIndex mandatory
Integer32
.1.3.6.1.4.1.6853.3.4.1.1
mduOutputCal mandatory r/w
.1.3.6.1.4.1.6853.3.4.1.10
mduOutputState mandatory r/w
Enumeration
.1.3.6.1.4.1.6853.3.4.1.2
mduOutputDelay mandatory r/w
.1.3.6.1.4.1.6853.3.4.1.3
mduOutputlowerCurrent mandatory r/w
.1.3.6.1.4.1.6853.3.4.1.4
mduOutputupperCurrent mandatory r/w
.1.3.6.1.4.1.6853.3.4.1.5
mduOutputCurrent mandatory
.1.3.6.1.4.1.6853.3.4.1.6
.1.3.6.1.4.1.6853.3.4.1.7
mduOutputVA mandatory
.1.3.6.1.4.1.6853.3.4.1.8
mduOutputWatts mandatory
.1.3.6.1.4.1.6853.3.4.1.9
mduPowerStatus mandatory
Enumeration
.1.3.6.1.4.1.6853.3.5
mduVoltageCal mandatory r/w
.1.3.6.1.4.1.6853.3.6
mduVoltage mandatory
.1.3.6.1.4.1.6853.3.7
mduVoltageFloor mandatory r/w
.1.3.6.1.4.1.6853.3.8
mduVoltageLimit mandatory r/w
.1.3.6.1.4.1.6853.3.9
Dependencies (3) 3 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. TSL-MIBtslselected
Type Definitions (1)
OctetString
Notifications / Traps (6)
NameOIDDescription
.1.3.6.1.4.1.6853.0.4
An entry in the alarm table has changed state
.1.3.6.1.4.1.6853.0.5
The equipment temperature has exceeded the maximum allowed
.1.3.6.1.4.1.6853.0.6
The equipment temperature is now within limits
.1.3.6.1.4.1.6853.0.7
The power input to the MDU has changed state
.1.3.6.1.4.1.6853.0.8
The voltage to the MDU has traversed a limit
.1.3.6.1.4.1.6853.0.9
The total current through the MDU has traversed a limit