TIMETRA-SAS-ALARM-INPUT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
9
.1.3.6.1.4.1.6527.6.2.2.2.9.1 · 1 row entry · 7 columns
Uses the nokia variant from /opt/observium/mibs/nokia.
Command help
Walk tmnxSasAlarmInputInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-SAS-ALARM-INPUT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmInputInfoTable'
The table tmnxSasAlarmInputInfoTable contains alarm input
configuration.
          
This table contains information about alarm inputs driven by external
equipment.
tmnxSasAlarmInputInfoEntry row .1.3.6.1.4.1.6527.6.2.2.2.9.1.1
The entry tmnxSasAlarmInputInfoEntry represents one alarm input
contact.

Rows in this table are created at startup by SROS. Rows in this table
are never destroyed.
Column Syntax OID
The value of tmnxSasAlarmInputId specifies the alarm contact
identifier.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.1
The value of tmnxSasAlarmInputDescription specifies the description of
this alarm input entry.
OctetStringr/w
Constraints:
range: 0-160
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.2
The value of tmnxSasAlarmInputAdminState specifies the administrative
state of the alarm input.

Values:
up (1) - Specifies that a given alarm-input is operational.
down (2) - Specifies that a g…
Enumerationr/w
Enumerated Values:
1up
2down
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.3
The value of tmnxSasAlarmInputPolarity specifies the polarity of the
alarm input circuit. This value specifies if the state of alram input
when it is in normal operation (i.e. when there is no alarm).

Val…
Enumerationr/w
Enumerated Values:
1normallyOpen
2normallyClosed
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.4
The value of tmnxSasAlarmOutputSeverity specifies the configured
output severity of the alarm.

Values:
none (1) - Specifies that severity of the alarm is none.
minor (2) - Specifies that se…
Enumerationr/w
Enumerated Values:
1none
2minor
3major
4critical
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5
The value of tmnxSasAlarmInputStatus indicates the current status of
the alarm.

Values:
noAlarm (1) - Indicates that there was no alarm raised.
alarm (2) - Indicates that there was an alarm ra…
Enumeration
Enumerated Values:
1noAlarm
2alarm
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.6
The value of tmnxSasAlarmInputLastChange indicates the value of
sysUpTime at the time of the last configuration change an object in
the specified row.
SNMPv2-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.7
.1.3.6.1.4.1.6527.6.2.2.2.9.2 · 1 row entry · 2 columns
Uses the nokia variant from /opt/observium/mibs/nokia.
Command help
Walk tmnxSasAlarmInputMessageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-SAS-ALARM-INPUT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-SAS-ALARM-INPUT-MIB::tmnxSasAlarmInputMessageTable'
The table tmnxSasAlarmInputMessageTable contains user defined messages
that are configured to be sent out with notifications.
          
This table contains information about the messages that have been
configured to be sent out in the alarm for each alarm input. This
table permits the trigger message and clear message to be defined
independently.
tmnxSasAlarmInputMessageEntry row .1.3.6.1.4.1.6527.6.2.2.2.9.2.1
The value of tmnxSasAlarmInputMessageEntry represents one alarm input
contact.

Rows in the table tmnxSasAlarmInputMessageTable are created at SROS
startup and are never destroyed.
Column Syntax OID
The value of tmnxSasAlarmInputTriggerMessage specifies the user
defined alarm trigger event description, for a given alarm input, to
be sent out to NMS in a SNMP trap when the alarm triggers.
OctetStringr/w
Constraints:
range: 0-80
.1.3.6.1.4.1.6527.6.2.2.2.9.2.1.1
The value of tmnxSasAlarmInputClearMessage specifies the user defined
alarm clear event description, for a given alarm input, to be sent out
to NMS in a SNMP trap when the alarm clears.
OctetStringr/w
Constraints:
range: 0-80
.1.3.6.1.4.1.6527.6.2.2.2.9.2.1.2