TIMETRA-SAS-ALARM-INPUT-MIB

        This document is the SNMP MIB module for the Nokia SROS implementation
of Alarm Contact Inputs.
        
Copyright 2003-2018 Nokia. All rights reserved. Reproduction of this
document is authorized on the condition that the foregoing copyright
notice is included.
        
This SNMP MIB module (Specification) embodies Nokia's proprietary
intellectual property. Nokia retains all title and ownership in the
Specification, including any revisions.
        
Nokia grants all interested parties a non-exclusive license
to  use and distribute an unmodified copy of this Specification
in connection with management of Nokia products, and without
fee, provided this copyright notice and license appear on all
copies.
        
This Specification is  supplied `as is', and Nokia makes no
warranty, either express or implied, as to the use, operation,
condition, or performance of the Specification.
    

Imported Objects

MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUPSNMPv2-CONF
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, TimeTicksSNMPv2-SMI
tmnxChassisNotifyHwIndex, tmnxHwClass, tmnxHwIDTIMETRA-CHASSIS-MIB
tmnxBasedProductsTIMETRA-GLOBAL-MIB
TItemLongDescriptionTIMETRA-TC-MIB

Objects

timetraServiceAccessSwitches .1.3.6.1.4.1.6527.6.2
timetraSASRegistry .1.3.6.1.4.1.6527.6.2.1
timetraSASModules .1.3.6.1.4.1.6527.6.2.1.1
tmnxSasAlarmInputMIBModule .1.3.6.1.4.1.6527.6.2.1.1.10
timetraSASMIB .1.3.6.1.4.1.6527.6.2.2
timetraSASConfs .1.3.6.1.4.1.6527.6.2.2.1
tmnxSASAlarmInputConformance .1.3.6.1.4.1.6527.6.2.2.1.6
tmnxSASAlarmInputCompliances .1.3.6.1.4.1.6527.6.2.2.1.6.1
tmnxSASAlarmInputGroups .1.3.6.1.4.1.6527.6.2.2.1.6.2
timetraSASObjs .1.3.6.1.4.1.6527.6.2.2.2
tmnxSasAlarmInputNotifyObjs .1.3.6.1.4.1.6527.6.2.2.2.10
tmnxSasAlarmInputNotifyId .1.3.6.1.4.1.6527.6.2.2.2.10.1
tmnxSasAlarmInputNotifyMessage .1.3.6.1.4.1.6527.6.2.2.2.10.2
tmnxSASChassisObjs .1.3.6.1.4.1.6527.6.2.2.2.6
tmnxSASChassisNotification .1.3.6.1.4.1.6527.6.2.2.2.6.2
tmnxSasAlarmInputObjs .1.3.6.1.4.1.6527.6.2.2.2.9
tmnxSasAlarmInputInfoTable .1.3.6.1.4.1.6527.6.2.2.2.9.1
tmnxSasAlarmInputInfoEntry .1.3.6.1.4.1.6527.6.2.2.2.9.1.1
tmnxSasAlarmInputId .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.1
tmnxSasAlarmInputDescription .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.2
tmnxSasAlarmInputAdminState .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.3
tmnxSasAlarmInputPolarity .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.4
tmnxSasAlarmOutputSeverity .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.5
tmnxSasAlarmInputStatus .1.3.6.1.4.1.6527.6.2.2.2.9.1.1.6
tmnxSasAlarmInputLastChange
.1.3.6.1.4.1.6527.6.2.2.2.9.1.1.7
tmnxSasAlarmInputMessageTable .1.3.6.1.4.1.6527.6.2.2.2.9.2
tmnxSasAlarmInputMessageEntry .1.3.6.1.4.1.6527.6.2.2.2.9.2.1
tmnxSasAlarmInputTriggerMessage .1.3.6.1.4.1.6527.6.2.2.2.9.2.1.1
tmnxSasAlarmInputClearMessage .1.3.6.1.4.1.6527.6.2.2.2.9.2.1.2
tmnxSasAlarmInputPowerStatus .1.3.6.1.4.1.6527.6.2.2.2.9.3
timetraSASNotifyPrefix .1.3.6.1.4.1.6527.6.2.2.3
tmnxSasAlarmInputNotifications .1.3.6.1.4.1.6527.6.2.2.3.10

Notifications/Traps

NameOIDDescription
tmnxAlarmInputVoltageFailure




.1.3.6.1.4.1.6527.6.2.2.2.6.2.10
[CAUSE] A tmnxAlarmInputVoltageFailure notification is sent when  the
internal power supply for alarm inputs fails. The value of
tmnxSasAlarmInputPowerStatus indicates whether the power to external
alarm inputs is on or off.
          
[EFFECT] If the alarm inputs use the internal power supply, then a
 failure in the power supply will cause state change event
 alarms to not be raised.
          
[RECOVERY] Check the internal power source for alarm inputs and
rectify the problem.
tmnxSasAlarminput1StateChanged






.1.3.6.1.4.1.6527.6.2.2.3.10.1
[CAUSE] A tmnxSasAlarminput1StateChanged notification is sent when
status of the alarm input on pin one(1) changes.
          
          
When this notification is sent, the field
tmnxSasAlarmInputNotifyMessage is populated with either the
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
tmnxSasAlarmInputClearMessage when the alarm is cleared.
          
The trigger or clear actions depend on the polarity of the input as
defined in tmnxSasAlarmInputPolarity.
          
[EFFECT] A desirable or undesirable event has occurred in the external
equipment connected to the alarm input. Hence the characteristics of
effect and the associated risks vary depending on the nature of the
external equipment being monitored over the alarm input.
          
[RECOVERY] Check the external equipment, connected to the alarm input
pin one(1), that resulted in this alarm and rectify the problem.
tmnxSasAlarminput2StateChanged






.1.3.6.1.4.1.6527.6.2.2.3.10.2
[CAUSE] A tmnxSasAlarminput2StateChanged notification is sent when
status of the alarm input on pin two(2) changes.
          
When this notification is sent, the field
tmnxSasAlarmInputNotifyMessage is populated with either the
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
tmnxSasAlarmInputClearMessage when the alarm is cleared.
          
The trigger or clear actions depend on the polarity of the input as
defined in tmnxSasAlarmInputPolarity.
          
[EFFECT] A desirable or undesirable event has occurred in the external
equipment connected to the alarm input. Hence the characteristics of
effect and the associated risks vary depending on the nature of the
external equipment being monitored over the alarm input.
          
[RECOVERY] Check the external equipment, connected to the alarm input
pin two(2), that resulted in this alarm and rectify the problem.
tmnxSasAlarminput3StateChanged






.1.3.6.1.4.1.6527.6.2.2.3.10.3
[CAUSE] A tmnxSasAlarminput3StateChanged notification is sent when
status of the alarm input on pin three(3) changes.
          
When this notification is sent, the field
tmnxSasAlarmInputNotifyMessage is populated with either the
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
tmnxSasAlarmInputClearMessage when the alarm is cleared.
          
The trigger or clear actions depend on the polarity of the input as
defined in tmnxSasAlarmInputPolarity.
          
[EFFECT] A desirable or undesirable event has occurred in the external
equipment connected to the alarm input. Hence the characteristics of
effect and the associated risks vary depending on the nature of the
external equipment being monitored over the alarm input.
          
[RECOVERY] Check the external equipment, connected to the alarm input
pin three(3), that resulted in this alarm and rectify the problem.
tmnxSasAlarminput4StateChanged






.1.3.6.1.4.1.6527.6.2.2.3.10.4
[CAUSE] A tmnxSasAlarminput4StateChanged notification is sent when
status of the alarm input on pin four(4) changes.
          
When this notification is sent, the field
tmnxSasAlarmInputNotifyMessage is populated with either the
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
tmnxSasAlarmInputClearMessage when the alarm is cleared.
          
The trigger or clear actions depend on the polarity of the input as
defined in tmnxSasAlarmInputPolarity.
          
[EFFECT] A desirable or undesirable event has occurred in the external
equipment connected to the alarm input. Hence the characteristics of
effect and the associated risks vary depending on the nature of the
external equipment being monitored over the alarm input.
          
[RECOVERY] Check the external equipment, connected to the alarm input
pin four(4), that resulted in this alarm and rectify the problem.