TIMETRA-POWER-SHELF-MIB

        This document is the SNMP MIB module for the Nokia SROS implementation
of Power Shelf.
        
Copyright (c) 2017-2018 Nokia. All rights reserved. Reproduction of
this document is authorized on the condition that the foregoing
copyright notice is included.
        
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property.  Nokia retains all
title and ownership in the Specification, including any
revisions.
        
Nokia grants all interested parties a non-exclusive license to use and
distribute an unmodified copy of this Specification in connection with
management of Nokia products, and without fee, provided this copyright
notice and license appear on all copies.
        
This Specification is supplied `as is', and Nokia makes no warranty,
either express or implied, as to the use, operation, condition, or
performance of the Specification.
    
Source file
TIMETRA-POWER-SHELF-MIB
Last revised
Identity
timetraPowerShelfMIBModule
Base OID
1.3.6.1.4.1.6527.1.1.3.118
Imported Objects
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC TEXTUAL-CONVENTION (no object page) TimeStamp
TIMETRA-CHASSIS-MIB tmnxCpmPowerShelfCommsFail tmnxHwClass TmnxHwIndex
TIMETRA-GLOBAL-MIB timetraSRMIBModules tmnxSRConfs tmnxSRNotifyPrefix tmnxSRObjs
TIMETRA-TC-MIB TItemDescription TNamedItemOrEmpty
Net-SNMP examples using the nokia MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-POWER-SHELF-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-POWER-SHELF-MIB::timetraPowerShelfMIBModule'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-POWER-SHELF-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-POWER-SHELF-MIB::timetraPowerShelfMIBModule'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (26)
.1.3.6.1.4.1.6527.1.1.3.118
.1.3.6.1.4.1.6527.3.1.1.118
.1.3.6.1.4.1.6527.3.1.1.118.1
.1.3.6.1.4.1.6527.3.1.1.118.2
.1.3.6.1.4.1.6527.3.1.2.118
.1.3.6.1.4.1.6527.3.1.2.118.1
.1.3.6.1.4.1.6527.3.1.2.118.1.1
.1.3.6.1.4.1.6527.3.1.2.118.2
.1.3.6.1.4.1.6527.3.1.2.118.2.1
.1.3.6.1.4.1.6527.3.1.2.118.2.1.1
.1.3.6.1.4.1.6527.3.1.2.118.2.1.2
.1.3.6.1.4.1.6527.3.1.2.118.2.1.3
.1.3.6.1.4.1.6527.3.1.2.118.3
.1.3.6.1.4.1.6527.3.1.2.118.3.1
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.1
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.2
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.3
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.4
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.5
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.6
amperesUnsigned32
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.7
Enumeration
.1.3.6.1.4.1.6527.3.1.2.118.3.1.1.8
.1.3.6.1.4.1.6527.3.1.3.120
.1.3.6.1.4.1.6527.3.1.3.120.0
.1.3.6.1.4.1.6527.3.1.3.120.0.1
Dependencies (8) 6 direct · 2 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Type Definitions (2)
Bits
invalidPowerShelfType(0)
unassigned(1)
suppPowerShelfType2(2)
suppPowerShelfType3(3)
suppPowerShelfType4(4)
suppPowerShelfType5(5)
suppPowerShelfType6(6)
suppPowerShelfType7(7)
suppPowerShelfType8(8)
suppPowerShelfType9(9)
suppPowerShelfType10(10)
suppPowerShelfType11(11)
suppPowerShelfType12(12)
suppPowerShelfType13(13)
suppPowerShelfType14(14)
suppPowerShelfType15(15)
Unsigned32
Compliance Statements (1)

OID .1.3.6.1.4.1.6527.3.1.1.118.1.1
The compliance statement for management of power shelves for release
16.0 on Nokia SROS series systems.
Required groups
Notifications / Traps (6)
NameOIDDescription
.1.3.6.1.4.1.6527.3.1.3.120.0.1.1
[CAUSE] The tmnxPowerShelfInputPwrModeSwitch is generated when
tmnxPowerShelfInputPowerMode has changed value.

[EFFECT] No effect.

[RECOVERY] No recovery required.
.1.3.6.1.4.1.6527.3.1.3.120.0.1.2
[CAUSE] The tmnxPowerShelfCommsDown is generated when there is a loss
of communications with the power shelf controller.

[EFFECT] If there is a power failure, it will not be detected since
the power modules cannot be polled. The system will continue to report
the state of the power modules as they were when last seen.

[RECOVERY] Correct the power shelf controller communications problem.
.1.3.6.1.4.1.6527.3.1.3.120.0.1.3
[CAUSE] The tmnxPowerShelfCommsUp notification is generated when a
loss of communications with the power shelf controller has been
resolved.

[EFFECT] Power failures can be detected.

[RECOVERY] No recovery required.
.1.3.6.1.4.1.6527.3.1.3.120.0.1.4
[CAUSE] The tmnxPowerShelfOutputStatusSwitch is generated when
tmnxPowerShelfOutputStatus has changed value.

[EFFECT] No effect.

[RECOVERY] No recovery required.
.1.3.6.1.4.1.6527.3.1.3.120.0.1.5
[CAUSE] The tmnxPowerShelfOutputStatusSwitch is generated when the
physical output switch on the power shelf is set to Standby.

[EFFECT] The power output from the identified power shelf is switched
off and does not supply power to the system.

[RECOVERY] Set output switch to On to restore power output.
.1.3.6.1.4.1.6527.3.1.3.120.0.1.6
[CAUSE] The tmnxPowerShelfOutputStatusSwitch is generated when the
physical output switch on the power shelf is set to On.

[EFFECT] Power output from the identified power shelf is enabled and
now supplies power to the system.

[RECOVERY] No recovery required.