T11-FC-SP-ZONING-MIB

        This MIB module specifies the extensions to the
T11-FC-ZONE-SERVER-MIB module that are necessary for the
management of Fibre Channel's FC-SP Zoning Servers, as
defined in the FC-SP specification.
        
The persistence of values written to these MIB objects is
the same as the persistence of the objects they extend,
i.e., it is given by the value of the relevant instance of
t11ZsServerDatabaseStorageType (defined in the
T11-FC-ZONE-SERVER-MIB module).
        
Copyright (C) The IETF Trust (2008).  This version
of this MIB module is part of RFC 5324;  see the RFC
itself for full legal notices.
    
Source file
T11-FC-SP-ZONING-MIB
Last revised
Identity
t11FcSpZoningMIB
Base OID
1.3.6.1.2.1.177
Imported Objects
IF-MIB ifIndex
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Counter32 mib-2 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC TruthValue
T11-FC-SP-TC-MIB T11FcSpHashCalculationStatus T11FcSpPolicyHashFormat T11FcSpPolicyHashValue
T11-FC-ZONE-SERVER-MIB t11ZsFabricIndex t11ZsNotifyControlEntry t11ZsServerEntry t11ZsStatsEntry
Net-SNMP examples using the rfc MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'T11-FC-SP-ZONING-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'T11-FC-SP-ZONING-MIB::t11FcSpZoningMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'T11-FC-SP-ZONING-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'T11-FC-SP-ZONING-MIB::t11FcSpZoningMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (31)
.1.3.6.1.2.1.177
.1.3.6.1.2.1.177.0
.1.3.6.1.2.1.177.1
.1.3.6.1.2.1.177.1.1
.1.3.6.1.2.1.177.1.1.1
.1.3.6.1.2.1.177.1.1.1.1
Bits
.1.3.6.1.2.1.177.1.1.1.1.1
.1.3.6.1.2.1.177.1.1.1.1.2
.1.3.6.1.2.1.177.1.1.1.1.3
.1.3.6.1.2.1.177.1.1.1.1.4
.1.3.6.1.2.1.177.1.1.1.1.5
.1.3.6.1.2.1.177.1.1.1.1.6
.1.3.6.1.2.1.177.1.1.1.1.7
.1.3.6.1.2.1.177.1.1.2
.1.3.6.1.2.1.177.1.1.2.1
.1.3.6.1.2.1.177.1.1.2.1.1
.1.3.6.1.2.1.177.1.1.2.1.2
.1.3.6.1.2.1.177.1.2
.1.3.6.1.2.1.177.1.2.1
.1.3.6.1.2.1.177.1.2.1.1
.1.3.6.1.2.1.177.1.2.1.1.1
.1.3.6.1.2.1.177.1.2.1.1.2
.1.3.6.1.2.1.177.1.2.1.1.3
.1.3.6.1.2.1.177.1.2.1.1.4
.1.3.6.1.2.1.177.1.2.1.1.5
.1.3.6.1.2.1.177.1.2.1.1.6
.1.3.6.1.2.1.177.1.2.1.1.7
.1.3.6.1.2.1.177.1.2.1.1.8
.1.3.6.1.2.1.177.2
.1.3.6.1.2.1.177.2.1
.1.3.6.1.2.1.177.2.2
Dependencies (13) 6 direct · 7 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Conformance Groups (4)
A collection of objects for Zone configuration

information of a Zone Server capable of
operating in FC-SP Zoning mode.
.1.3.6.1.2.1.177.2.2.1
A collection of notification control objects for
monitoring Zone Server failures specific to FC-SP.
.1.3.6.1.2.1.177.2.2.2
A collection of objects for collecting Zone Server
statistics which are specific to FC-SP.
.1.3.6.1.2.1.177.2.2.3
A collection of notification(s) for monitoring
Zone Server events that are specific to FC-SP.
.1.3.6.1.2.1.177.2.2.4
Compliance Statements (1)

OID .1.3.6.1.2.1.177.2.1.1
The compliance statement for entities that
implement the extensions specified in FC-SP for
Fibre Channel's Zone Server.
Required groups
mandatory t11FcSpZsObjectsGroup
mandatory t11FcSpZsNotificationControlGroup
mandatory t11FcSpZsNotificationGroup
optional t11FcSpZsStatisticsGroup These counters, containing Zone Server statistics,
are mandatory only for those systems that count
such events.
Object refinements
ObjectAccessSyntaxDescription
t11FcSpZsServerEnabled readonly
Write access is not required.
t11FcSpZoneSetHashStatus readonly
Write access is not required.
t11FcSpZsNotifyJoinSuccessEnable readonly
Write access is not required.
t11FcSpZsNotifyJoinFailureEnable readonly
Write access is not required.
Notifications / Traps (2)
NameOIDDescription
.1.3.6.1.2.1.177.0.1
This notification indicates that a Switch that is part
of one Fabric (indicated by the value of t11ZsFabricIndex)
has successfully joined (on the interface indicated by the
value of ifIndex) with a Switch that is part of another
Fabric.

If multiple Virtual Fabrics are configured on an interface,
and all are successfully joined at the same time, and if
the agent so chooses, then it can generate just one
notification in which t11ZsFabricIndex has the value 4096.
.1.3.6.1.2.1.177.0.2
This notification indicates that an E_Port on the local
Switch has entered the Isolated state because a join
between two Fabrics failed. The failure occurred on the
local Fabric indicated by the value of t11ZsFabricIndex,
on the interface indicated by the value of ifIndex.

If multiple Virtual Fabrics are configured on an interface,
and all have a failure to join at the same time, and if the
agent so chooses, then it can generate just one notification
in which t11ZsFabricIndex has the value 4096.