SYNOLOGY-UPS-MIB

Download MIB Monitored by Observium

Characteristics of the ups information

Observium actively monitors this MIB Visit Observium
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Source file
SYNOLOGY-UPS-MIB
Last revised
Identity
synoUPS
Base OID
1.3.6.1.4.1.6574.4
Objects
123 scalars · 0 columns
Tables
0 tables
Net-SNMP examples using the synology MIB directory

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SYNOLOGY-UPS-MIB' -M '/opt/observium/mibs/synology:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SYNOLOGY-UPS-MIB::synoUPS'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNOLOGY-UPS-MIB' -M '/opt/observium/mibs/synology:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNOLOGY-UPS-MIB::synoUPS'
Command help
Imported Objects
Float
SNMPv2-CONF MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI enterprises Integer32 MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page)

Objects

OBS ✓7

ScalarsupsDevice

synoUPS · .1.3.6.1.4.1.6574.4.1
Object Syntax OID
upsDeviceModelOBS ✓OctetString.1.3.6.1.4.1.6574.4.1.1
upsDeviceManufacturerOctetString.1.3.6.1.4.1.6574.4.1.2
upsDeviceSerialOctetString.1.3.6.1.4.1.6574.4.1.3
upsDeviceTypeOctetString.1.3.6.1.4.1.6574.4.1.4
upsDeviceDescriptionOctetString.1.3.6.1.4.1.6574.4.1.5
upsDeviceContactOctetString.1.3.6.1.4.1.6574.4.1.6
upsDeviceLocationOctetString.1.3.6.1.4.1.6574.4.1.7
upsDevicePartOctetString.1.3.6.1.4.1.6574.4.1.8
upsDeviceMACAddrOctetString.1.3.6.1.4.1.6574.4.1.9

ScalarsupsInfo

synoUPS · .1.3.6.1.4.1.6574.4.2
Object Syntax OID
upsInfoStatusOctetString.1.3.6.1.4.1.6574.4.2.1
upsInfoAlarmOctetString.1.3.6.1.4.1.6574.4.2.2
upsInfoTimeOctetString.1.3.6.1.4.1.6574.4.2.3
upsInfoDateOctetString.1.3.6.1.4.1.6574.4.2.4
upsInfoModelOctetString.1.3.6.1.4.1.6574.4.2.5
upsInfoSerialOctetString.1.3.6.1.4.1.6574.4.2.7
upsInfoVendorIDOctetString.1.3.6.1.4.1.6574.4.2.8
upsInfoProductIDOctetString.1.3.6.1.4.1.6574.4.2.9
upsInfoTemperaturedegree C.1.3.6.1.4.1.6574.4.2.11
upsInfoIDOctetString.1.3.6.1.4.1.6574.4.2.13
upsInfoDisplayLanguageOctetString.1.3.6.1.4.1.6574.4.2.17
upsInfoContactsOctetString.1.3.6.1.4.1.6574.4.2.18
upsInfoEffciencypercentNonNegativeInteger.1.3.6.1.4.1.6574.4.2.19
upsInfoBeeperStatusOctetString.1.3.6.1.4.1.6574.4.2.22
upsInfoTypeOctetString.1.3.6.1.4.1.6574.4.2.23
upsInfoWatchdogStatusOctetString.1.3.6.1.4.1.6574.4.2.24

ScalarsupsInfoMfr

upsInfo · .1.3.6.1.4.1.6574.4.2.6
Object Syntax OID
upsInfoMfrNameOctetString.1.3.6.1.4.1.6574.4.2.6.1
upsInfoMfrDateOctetString.1.3.6.1.4.1.6574.4.2.6.2

ScalarsupsInfoFirmware

upsInfo · .1.3.6.1.4.1.6574.4.2.10
Object Syntax OID
upsInfoFirmwareNameOctetString.1.3.6.1.4.1.6574.4.2.10.1
upsInfoFirmwareAuxOctetString.1.3.6.1.4.1.6574.4.2.10.2

ScalarsupsInfoLoad

upsInfo · .1.3.6.1.4.1.6574.4.2.12
Object Syntax OID
upsInfoLoadValueOBS ✓percentage.1.3.6.1.4.1.6574.4.2.12.1
upsInfoLoadHighpercentage.1.3.6.1.4.1.6574.4.2.12.2

ScalarsupsInfoDelay

upsInfo · .1.3.6.1.4.1.6574.4.2.14
Object Syntax OID
upsInfoDelayStartsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.14.1
upsInfoDelayRebootsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.14.2
upsInfoDelayShutdownsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.14.3

ScalarsupsInfoTimer

upsInfo · .1.3.6.1.4.1.6574.4.2.15
Object Syntax OID
upsInfoTimerStartsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.15.1
upsInfoTimerRebootsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.15.2
upsInfoTimerShutdownsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.15.3

ScalarsupsInfoTest

upsInfo · .1.3.6.1.4.1.6574.4.2.16
Object Syntax OID
upsInfoTestIntervalsecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.2.16.1
upsInfoTestResultOctetString.1.3.6.1.4.1.6574.4.2.16.2

ScalarsupsInfoPower

upsInfo · .1.3.6.1.4.1.6574.4.2.20
Object Syntax OID
upsInfoPowerValueVolt-Amps.1.3.6.1.4.1.6574.4.2.20.1
upsInfoPowerNominalVolt-Amps.1.3.6.1.4.1.6574.4.2.20.2

ScalarsupsInfoRealPower

upsInfo · .1.3.6.1.4.1.6574.4.2.21
Object Syntax OID
upsInfoRealPowerValueWatts.1.3.6.1.4.1.6574.4.2.21.1
upsInfoRealPowerNominalWatts.1.3.6.1.4.1.6574.4.2.21.2

ScalarsupsInfoStart

upsInfo · .1.3.6.1.4.1.6574.4.2.25
Object Syntax OID
upsInfoStartAutoOctetString.1.3.6.1.4.1.6574.4.2.25.1
upsInfoStartBatteryOctetString.1.3.6.1.4.1.6574.4.2.25.2
upsInfoStartRebootOctetString.1.3.6.1.4.1.6574.4.2.25.3

ScalarsupsBatteryCharge

upsBattery · .1.3.6.1.4.1.6574.4.3.1
Object Syntax OID
upsBatteryChargeValueOBS ✓Percent.1.3.6.1.4.1.6574.4.3.1.1
upsBatteryChargeLowPercent.1.3.6.1.4.1.6574.4.3.1.2
upsBatteryChargeRestartPercent.1.3.6.1.4.1.6574.4.3.1.3
upsBatteryChargeWarningPercent.1.3.6.1.4.1.6574.4.3.1.4

ScalarsupsBatteryVoltage

upsBattery · .1.3.6.1.4.1.6574.4.3.2
Object Syntax OID
upsBatteryVoltageValueOBS ✓Volt DC.1.3.6.1.4.1.6574.4.3.2.1
upsBatteryVoltageNominalVolt DC.1.3.6.1.4.1.6574.4.3.2.2
upsBatteryVoltageLowVolt DC.1.3.6.1.4.1.6574.4.3.2.3
upsBatteryVoltageHighVolt DC.1.3.6.1.4.1.6574.4.3.2.4

ScalarsupsBattery

synoUPS · .1.3.6.1.4.1.6574.4.3
Object Syntax OID
upsBatteryCapacityA.1.3.6.1.4.1.6574.4.3.3
upsBatteryCurrentAmp DC.1.3.6.1.4.1.6574.4.3.4
upsBatteryTemperaturedegrees Centigrade.1.3.6.1.4.1.6574.4.3.5
upsBatteryAlarmThresholdOctetString.1.3.6.1.4.1.6574.4.3.7
upsBatteryDateOctetString.1.3.6.1.4.1.6574.4.3.8
upsBatteryMfrDateOctetString.1.3.6.1.4.1.6574.4.3.9
upsBatteryPacksNonNegativeInteger.1.3.6.1.4.1.6574.4.3.10
upsBatteryPacksBadNonNegativeInteger.1.3.6.1.4.1.6574.4.3.11
upsBatteryTypeOctetString.1.3.6.1.4.1.6574.4.3.12
upsBatteryProtectionOctetString.1.3.6.1.4.1.6574.4.3.13
upsBatteryEnergySaveOctetString.1.3.6.1.4.1.6574.4.3.14

ScalarsupsBatteryRuntime

upsBattery · .1.3.6.1.4.1.6574.4.3.6
Object Syntax OID
upsBatteryRuntimeValueOBS ✓SecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.3.6.1
upsBatteryRuntimeLowSecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.3.6.2
upsBatteryRuntimeRestartSecondsNonNegativeInteger.1.3.6.1.4.1.6574.4.3.6.3

ScalarsupsInputVoltage

upsInput · .1.3.6.1.4.1.6574.4.4.1
Object Syntax OID
upsInputVoltageValueOBS ✓Volts.1.3.6.1.4.1.6574.4.4.1.1
upsInputVoltageMaxVolts.1.3.6.1.4.1.6574.4.4.1.2
upsInputVoltageMinVolts.1.3.6.1.4.1.6574.4.4.1.3
upsInputVoltageNominalVolts.1.3.6.1.4.1.6574.4.4.1.4
upsInputVoltageExtendOctetString.1.3.6.1.4.1.6574.4.4.1.5
upsInputVoltageFaultVolts.1.3.6.1.4.1.6574.4.4.1.6

ScalarsupsInputTransfer

upsInput · .1.3.6.1.4.1.6574.4.4.2
Object Syntax OID
upsInputTransferReasonOctetString.1.3.6.1.4.1.6574.4.4.2.1
upsInputTransferLowVolts.1.3.6.1.4.1.6574.4.4.2.2
upsInputTransferHighVolts.1.3.6.1.4.1.6574.4.4.2.3
upsInputTransferLowMinVolts.1.3.6.1.4.1.6574.4.4.2.4
upsInputTransferLowMaxVolts.1.3.6.1.4.1.6574.4.4.2.5
upsInputTransferHighMinVolts.1.3.6.1.4.1.6574.4.4.2.6
upsInputTransferHighMaxVolts.1.3.6.1.4.1.6574.4.4.2.7
upsInputTransferBoostLowVolts.1.3.6.1.4.1.6574.4.4.2.8
upsInputTransferBoostHighVolts.1.3.6.1.4.1.6574.4.4.2.9
upsInputTransferTrimLowVolts.1.3.6.1.4.1.6574.4.4.2.10
upsInputTransferTrimHighVolts.1.3.6.1.4.1.6574.4.4.2.11

ScalarsupsInput

synoUPS · .1.3.6.1.4.1.6574.4.4
Object Syntax OID
upsInputSensitivityOctetString.1.3.6.1.4.1.6574.4.4.3
upsInputQualityOctetString.1.3.6.1.4.1.6574.4.4.4

ScalarsupsInputCurrent

upsInput · .1.3.6.1.4.1.6574.4.4.5
Object Syntax OID
upsInputCurrentValueAmp.1.3.6.1.4.1.6574.4.4.5.1
upsInputCurrentNominalAmp.1.3.6.1.4.1.6574.4.4.5.2

ScalarsupsInputFrequency

upsInput · .1.3.6.1.4.1.6574.4.4.6
Object Syntax OID
upsInputFrequencyValueHz.1.3.6.1.4.1.6574.4.4.6.1
upsInputFrequencyNominalHz.1.3.6.1.4.1.6574.4.4.6.2
upsInputFrequencyLowHz.1.3.6.1.4.1.6574.4.4.6.3
upsInputFrequencyHighHz.1.3.6.1.4.1.6574.4.4.6.4
upsInputFrequencyExtendOctetString.1.3.6.1.4.1.6574.4.4.6.5

ScalarsupsOutputVoltage

upsOutput · .1.3.6.1.4.1.6574.4.5.1
Object Syntax OID
upsOutputVoltageValueOBS ✓Volts.1.3.6.1.4.1.6574.4.5.1.1
upsOutputVoltageNominalVolts.1.3.6.1.4.1.6574.4.5.1.2

ScalarsupsOutputFrequency

upsOutput · .1.3.6.1.4.1.6574.4.5.2
Object Syntax OID
upsOutputFrequencyValueHz.1.3.6.1.4.1.6574.4.5.2.1
upsOutputFrequencyNominalHz.1.3.6.1.4.1.6574.4.5.2.2

ScalarsupsOutputCurrent

upsOutput · .1.3.6.1.4.1.6574.4.5.3
Object Syntax OID
upsOutputCurrentValueAmp.1.3.6.1.4.1.6574.4.5.3.1
upsOutputCurrentNominalAmp.1.3.6.1.4.1.6574.4.5.3.2

ScalarsupsAmbientTemperature

upsAmbient · .1.3.6.1.4.1.6574.4.6.1
Object Syntax OID
upsAmbientTemperatureValuedegrees Centigrade.1.3.6.1.4.1.6574.4.6.1.1
upsAmbientTemperatureAlarmenabled/disabledOctetString.1.3.6.1.4.1.6574.4.6.1.2
upsAmbientTemperatureHighdegrees Centigrade.1.3.6.1.4.1.6574.4.6.1.3
upsAmbientTemperatureLowdegrees Centigrade.1.3.6.1.4.1.6574.4.6.1.4
upsAmbientTemperatureMaxdegrees Centigrade.1.3.6.1.4.1.6574.4.6.1.5
upsAmbientTemperatureMindegrees Centigrade.1.3.6.1.4.1.6574.4.6.1.6

ScalarsupsAmbientHumidity

upsAmbient · .1.3.6.1.4.1.6574.4.6.2
Object Syntax OID
upsAmbientHumidityValuepercent.1.3.6.1.4.1.6574.4.6.2.1
upsAmbientHumidityAlarmenabled/disabledOctetString.1.3.6.1.4.1.6574.4.6.2.2
upsAmbientHumidityHighpercent.1.3.6.1.4.1.6574.4.6.2.3
upsAmbientHumidityLowpercent.1.3.6.1.4.1.6574.4.6.2.4
upsAmbientHumidityMaxpercent.1.3.6.1.4.1.6574.4.6.2.5
upsAmbientHumidityMinpercent.1.3.6.1.4.1.6574.4.6.2.6

ScalarsupsDriver

synoUPS · .1.3.6.1.4.1.6574.4.7
Object Syntax OID
upsDriverNameOctetString.1.3.6.1.4.1.6574.4.7.1
upsDriverVersionOctetString.1.3.6.1.4.1.6574.4.7.2
upsDriverVersionDataOctetString.1.3.6.1.4.1.6574.4.7.3
upsDriverVersionInternalOctetString.1.3.6.1.4.1.6574.4.7.4
upsDriverPollIntervalsecondSNMPv2-SMIInteger32.1.3.6.1.4.1.6574.4.7.5
upsDriverPortOctetString.1.3.6.1.4.1.6574.4.7.6
upsDriverPollFrequencySNMPv2-SMIInteger32.1.3.6.1.4.1.6574.4.7.7
upsDriverProductIDOctetString.1.3.6.1.4.1.6574.4.7.8
upsDriverSnmpVersionOctetString.1.3.6.1.4.1.6574.4.7.9

ScalarsupsServer

synoUPS · .1.3.6.1.4.1.6574.4.8
Object Syntax OID
upsServerInfoOctetString.1.3.6.1.4.1.6574.4.8.1
upsServerVersionOctetString.1.3.6.1.4.1.6574.4.8.2

Type Definitions (1)

TypeSyntaxConstraints
NonNegativeInteger Integer32 1 constraints

Conformance Groups (1)

upsGroup .1.3.6.1.4.1.6574.4.9.2.1 Members (123)

Compliance Statements (1)

upsCompliance .1.3.6.1.4.1.6574.4.9.1.1
Dependencies (3) 3 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-CONFrfc
  3. SNMPv2-TCrfc
  4. SYNOLOGY-UPS-MIBsynologyselected