SWSYSTEM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
11
.1.3.6.1.4.1.1588.2.1.1.1.1.22 · 1 row entry · 5 columns
Uses the brocade variant from /opt/observium/mibs/brocade.
Command help
Walk swSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SWSYSTEM-MIB' -M '/opt/observium/mibs/brocade:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SWSYSTEM-MIB::swSensorTable'
The table of sensor entries.
swSensorEntry row .1.3.6.1.4.1.1588.2.1.1.1.1.22.1
An entry of the sensor information.
Indexes
Column Syntax OID
This object identifies the sensor.
Brocade-TCSwSensorIndex
Type Constraints:
range: 1..1024
.1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1
This object identifies the sensor type.
Enumeration
Enumerated Values:
1temperature
2fan
3power-supply
.1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2
The current status of the sensor.
Enumeration
Enumerated Values:
1unknown
2faulty
3below-min
4nominal
5above-max
6absent
.1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3
The current value (reading) of the sensor.
The value, -2147483648, represents an unknown quantity.
It also means that the sensor does not have the capability to
measure the actual value. In V2.0, the temperature sensor
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4
Additional displayable information on the sensor.
In V2.x, it contains the sensor type and number
in textual format. For example, 'Temp 3', 'Fan 6'.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5

swEventTable

table
.1.3.6.1.4.1.1588.2.1.1.1.8.5 · 1 row entry · 6 columns
Uses the brocade variant from /opt/observium/mibs/brocade.
Command help
Walk swEventTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SWSYSTEM-MIB' -M '/opt/observium/mibs/brocade:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SWSYSTEM-MIB::swEventTable'
The table of event entries.
swEventEntry row .1.3.6.1.4.1.1588.2.1.1.1.8.5.1
An entry of the event table.
Indexes
Column Syntax OID
This object identifies the event entry.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.1
This object identifies the date and time when this
event occurred, in textual format.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.2
This object identifies the severity level of this
event entry.
Enumeration
Enumerated Values:
1critical
2error
3warning
4informational
5debug
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.3
This object identifies how many times this particular
event has occurred.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.4
This object identifies the textual description of
the event.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.5
This object identifies the Virtual fabric id.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.1588.2.1.1.1.8.5.1.6