SUPERMICRO-RADIUS-MIB
The RADIUS ext. MIB is placed under supermicro MIB branch.
- Source file
SUPERMICRO-RADIUS-MIB- Last revised
- Identity
futureRADIUSMIB- Base OID
1.3.6.1.4.1.10876.101.1.25- Objects
- 2 scalars · 8 columns
- Tables
- 1 tables
Net-SNMP examples using the supermicro MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SUPERMICRO-RADIUS-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SUPERMICRO-RADIUS-MIB::futureRADIUSMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SUPERMICRO-RADIUS-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SUPERMICRO-RADIUS-MIB::futureRADIUSMIB'
Imported Objects
| IF-MIB | InterfaceIndex |
| SNMPv2-SMI | enterprises Integer32 IpAddress MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page) |
| SNMPv2-TC | DisplayString RowStatus |
radiusExtClient
futureRADIUSMIB ·
.1.3.6.1.4.1.10876.101.1.25.1
| Object | Syntax | OID |
|---|---|---|
| radiusExtDebugMask | SNMPv2-SMIInteger32r/w | .1.3.6.1.4.1.10876.101.1.25.1.1 |
| radiusMaxNoOfUserEntries | Integer32r/w | .1.3.6.1.4.1.10876.101.1.25.1.2 |
.1.3.6.1.4.1.10876.101.1.25.1.3
· 8 columns
The (conceptual) table listing the RADIUS servers with which the client shares a secret.
radiusExtServerEntry
.1.3.6.1.4.1.10876.101.1.25.1.3.1
Index
radiusExtServerIndex
| Column | Syntax | OID |
|---|---|---|
| radiusExtServerIndex | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10876.101.1.25.1.3.1.1 |
| radiusExtServerAddress | SNMPv2-SMIIpAddressr/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.2 |
| radiusExtServerType | Enumerationr/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.3 |
| radiusExtServerSharedSecret | SNMPv2-TCDisplayStringr/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.4 |
| radiusExtServerEnabled | Enumerationr/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.5 |
| radiusExtServerResponseTime | Integer32r/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.6 |
| radiusExtServerMaximumRetransmission | Integer32r/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.7 |
| radiusExtServerEntryStatus | SNMPv2-TCRowStatusr/w | .1.3.6.1.4.1.10876.101.1.25.1.3.1.8 |
Dependencies (6) 3 direct · 3 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- SNMPv2-CONFrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- SUPERMICRO-RADIUS-MIBsupermicroselected