SUPERMICRO-HEALTH-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
12
smHealthMonitorTable
table.1.3.6.1.4.1.10876.2.1.1.1
·
1 row entry
·
12 columns
Uses the supermicro variant from
Command help
/opt/observium/mibs/supermicro.
Walk smHealthMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SUPERMICRO-HEALTH-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SUPERMICRO-HEALTH-MIB::smHealthMonitorTable'
A table of health monitoring entries.
An entry in the health monitoring table.
Entries cannot be created or deleted via SNMP operations.
Entries cannot be created or deleted via SNMP operations.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The unique value identifies this Monitor device.
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.1 |
||||
|
A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator. |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.10876.2.1.1.1.1.2 |
||||
|
Identifies this Monitor device type.
|
SMHealthInfoTypes Type Constraints: range: 0..64 |
.1.3.6.1.4.1.10876.2.1.1.1.1.3 |
||||
|
Indicates the reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are displayed in Celsius. |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.4 |
||||
|
Indicates the the High limit for the Monitor device that are currently in use on the managed device.
This is applied to Temperature and Voltage devices only. Voltage limit is displayed in mV, and Temperture limit is dis… |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.5 |
||||
|
Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Ce… |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.6 |
||||
|
Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture read… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.7 |
||||
|
Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture read… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.10876.2.1.1.1.1.8 |
||||
|
Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
This is applied to Fan devices only. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.10876.2.1.1.1.1.9 |
||||
|
Indicates the monitoring status for the Fan device that are currently in use on the managed device.
0 = not monitored, 1 = monitored. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.10876.2.1.1.1.1.10 |
||||
|
Indicates the reading unit of the monitor device.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.10876.2.1.1.1.1.11 |
||||
|
Indicates the status of the monitor device. Values:
0: OK 1: Warning 2: Critical |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.10876.2.1.1.1.1.12 |