SUPERMICRO-HEALTH-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
12
.1.3.6.1.4.1.10876.2.1.1.1 · 1 row entry · 12 columns
Uses the supermicro variant from /opt/observium/mibs/supermicro.
Command help
Walk smHealthMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SUPERMICRO-HEALTH-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SUPERMICRO-HEALTH-MIB::smHealthMonitorTable'
A table of health monitoring entries.
smHealthMonitorEntry row .1.3.6.1.4.1.10876.2.1.1.1.1
An entry in the health monitoring table.
Entries cannot be created or deleted via SNMP operations.
Column Syntax OID
The unique value identifies this Monitor device.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.1
A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.10876.2.1.1.1.1.2
Identifies this Monitor device type.
SMHealthInfoTypes
Type Constraints:
range: 0..64
.1.3.6.1.4.1.10876.2.1.1.1.1.3
Indicates the reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture readings are displayed in Celsius.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.4
Indicates the the High limit for the Monitor device that are currently in use on the managed device.
This is applied to Temperature and Voltage devices only.
Voltage limit is displayed in mV, and Temperture limit is dis…
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.5
Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Ce…
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.6
Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture read…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.7
Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture read…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.8
Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
This is applied to Fan devices only.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10876.2.1.1.1.1.9
Indicates the monitoring status for the Fan device that are currently in use on the managed device.
0 = not monitored, 1 = monitored.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.10876.2.1.1.1.1.10
Indicates the reading unit of the monitor device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.10876.2.1.1.1.1.11
Indicates the status of the monitor device. Values:
0: OK
1: Warning
2: Critical
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10876.2.1.1.1.1.12