STORMSHIELD-SYSTEM-MONITOR-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
21
snsDiskTable
table.1.3.6.1.4.1.11256.1.10.5
·
1 row entry
·
6 columns
Uses the stormshield variant from
Command help
/opt/observium/mibs/stormshield.
Walk snsDiskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-SYSTEM-MONITOR-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-SYSTEM-MONITOR-MIB::snsDiskTable'
Disk information
Disk information
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of each disk in table
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.11256.1.10.5.1.1 |
|
Name of the disk
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.5.1.2 |
|
Result of the smart infos tests
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.5.1.3 |
|
Is the disk a member of a RAID array
|
Integer32 Constraints: range: 0-1 |
.1.3.6.1.4.1.11256.1.10.5.1.4 |
|
RAID Status
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.5.1.5 |
|
Disk Position
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.5.1.6 |
snsPowerSupplyTable
table.1.3.6.1.4.1.11256.1.10.6
·
1 row entry
·
3 columns
Uses the stormshield variant from
Command help
/opt/observium/mibs/stormshield.
Walk snsPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-SYSTEM-MONITOR-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-SYSTEM-MONITOR-MIB::snsPowerSupplyTable'
Power supply status of Firewall
Power supply information
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index of each line in table
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.11256.1.10.6.1.1 |
||||
|
Is power supply powered by electricity ?
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.11256.1.10.6.1.2 |
||||
|
What is the status of the power supply ?
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.6.1.3 |
snsCpuTable
table.1.3.6.1.4.1.11256.1.10.7
·
1 row entry
·
2 columns
Uses the stormshield variant from
Command help
/opt/observium/mibs/stormshield.
Walk snsCpuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-SYSTEM-MONITOR-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-SYSTEM-MONITOR-MIB::snsCpuTable'
CPU status of Firewalls
CPU information
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of each CPU in table
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.11256.1.10.7.1.1 |
|
Temperature in Celsius degree
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11256.1.10.7.1.2 |
snsBypassTable
table.1.3.6.1.4.1.11256.1.10.8
·
1 row entry
·
6 columns
Uses the stormshield variant from
Command help
/opt/observium/mibs/stormshield.
Walk snsBypassTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-SYSTEM-MONITOR-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-SYSTEM-MONITOR-MIB::snsBypassTable'
Bypass status of Firewalls
Bypass information
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Each line in the table
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.11256.1.10.8.1.1 |
||||
|
I2C Address of Bypass Device
|
Unsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.11256.1.10.8.1.2 |
||||
|
System-off Bypass status
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.11256.1.10.8.1.3 |
||||
|
Just-On Bypass status
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.11256.1.10.8.1.4 |
||||
|
Run-Time Bypass status
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.11256.1.10.8.1.5 |
||||
|
Run-Time Watchdog Timer state
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.8.1.6 |
snsFanTable
table.1.3.6.1.4.1.11256.1.10.9
·
1 row entry
·
4 columns
Uses the stormshield variant from
Command help
/opt/observium/mibs/stormshield.
Walk snsFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-SYSTEM-MONITOR-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-SYSTEM-MONITOR-MIB::snsFanTable'
Fans status of Firewalls
Fan information
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Each line in the table
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.11256.1.10.9.1.1 |
|
Name of the Fan
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.9.1.2 |
|
Status of the Fan
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.11256.1.10.9.1.3 |
|
Speed of the Fan
|
Unsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.11256.1.10.9.1.4 |