STE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
12

inpTable

table mandatory
.1.3.6.1.4.1.21796.4.1.1 · 1 row entry · 4 columns
Uses the hwgroup variant from /opt/observium/mibs/hwgroup.
Command help
Walk inpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STE-MIB' -M '/opt/observium/mibs/hwgroup:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STE-MIB::inpTable'
A list of binary input entries.
inpEntry row .1.3.6.1.4.1.21796.4.1.1.1
An entry containing information applicable
to a particular binary input.
Indexes
Column Syntax OID
inpIndexmandatory
The binary input index.
PositiveInteger
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.21796.4.1.1.1.1
inpValuemandatory
The binary input value.
OnOff
Type Values:
0off
1on
.1.3.6.1.4.1.21796.4.1.1.1.2
inpNamemandatory
The binary input name.
IOName
Type Constraints:
range: 0..16
.1.3.6.1.4.1.21796.4.1.1.1.3
inpAlarmStatemandatory
The binary input alarm state.
InputAlarmState
Type Values:
0normal
1alarm
.1.3.6.1.4.1.21796.4.1.1.1.4

sensTable

table mandatory
.1.3.6.1.4.1.21796.4.1.3 · 1 row entry · 8 columns
Uses the hwgroup variant from /opt/observium/mibs/hwgroup.
Command help
Walk sensTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STE-MIB' -M '/opt/observium/mibs/hwgroup:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STE-MIB::sensTable'
A list of sensor table entries. The number
of entries corresponds with number of detected sensors.
sensEntry row .1.3.6.1.4.1.21796.4.1.3.1
An entry containing information applicable to a
particular sensor.
Indexes
Column Syntax OID
sensIndexmandatory
The sensor index.
PositiveInteger
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.21796.4.1.3.1.1
sensNamemandatory
The sensor name.
SensorName
Type Constraints:
range: 0..16
.1.3.6.1.4.1.21796.4.1.3.1.2
sensStatemandatory
The sensor state.
SensorState
Type Values:
0invalid
1normal
2outofrangelo
3outofrangehi
4alarmlo
5alarmhi
.1.3.6.1.4.1.21796.4.1.3.1.3
sensStringmandatory
The string representation of sensor value.
SensorString
Type Constraints:
range: 0..10
.1.3.6.1.4.1.21796.4.1.3.1.4
sensValuemandatory
The integer (decimal * 10) representation
of sensor value.
SensorValue .1.3.6.1.4.1.21796.4.1.3.1.5
sensSNmandatory
The sensor Serial number.
SensorSN
Type Constraints:
range: 0..16
.1.3.6.1.4.1.21796.4.1.3.1.6
sensUnitmandatory
The sensor unit.
UnitType
Type Values:
0none
1celsius
2fahrenheit
3kelvin
4percent
.1.3.6.1.4.1.21796.4.1.3.1.7
sensIDmandatory
The sensor ID.
UnitType
Type Values:
0none
1celsius
2fahrenheit
3kelvin
4percent
.1.3.6.1.4.1.21796.4.1.3.1.8