SPECTRA-LOGIC-STRATA-MIB
Monitored by ObserviumThe Strata System MIB.
Observium actively monitors this MIB
Visit Observium
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity
IP addresses
Ports
Processors
Sensors
Status
Storage
- Source file
SPECTRA-LOGIC-STRATA-MIB- Last revised
- Identity
spectralogic- Base OID
1.3.6.1.4.1.3478- Objects
- 2 scalars · 183 columns
- Tables
- 25 tables
Net-SNMP examples using the spectralogic MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SPECTRA-LOGIC-STRATA-MIB' -M '/opt/observium/mibs/spectralogic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SPECTRA-LOGIC-STRATA-MIB::spectralogic'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SPECTRA-LOGIC-STRATA-MIB' -M '/opt/observium/mibs/spectralogic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SPECTRA-LOGIC-STRATA-MIB::spectralogic'
Imported Objects
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Counter32 Counter64 enterprises Integer32 IpAddress MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) TimeTicks |
| SNMPv2-TC | DateAndTime DisplayString RowStatus TEXTUAL-CONVENTION (no object page) TruthValue |
Objects
Showing 259 of 259 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link directly to their definitions on this MIB page. Hover or focus a linked name or badge for more details.
| spectralogic | .1.3.6.1.4.1.3478 | |
.1.3.6.1.4.1.3478.6 | ||
.1.3.6.1.4.1.3478.6.1 | ||
.1.3.6.1.4.1.3478.6.1.1 | ||
.1.3.6.1.4.1.3478.6.1.1.1 | ||
| cUserTable | .1.3.6.1.4.1.3478.6.1.1.1.1 | |
| cUserEntry | .1.3.6.1.4.1.3478.6.1.1.1.1.1 | |
| cUserIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.1.1.1.1.1 |
| cUserID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.1.1.1.2 |
| cUserUsername | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.1.1.1.3 |
| cUserFullname | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.1.1.1.4 |
| cUserRole | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.1.1.1.5 |
.1.3.6.1.4.1.3478.6.1.1.2 | ||
| cNetworkInterfaceTable | .1.3.6.1.4.1.3478.6.1.1.2.1 | |
| cNetworkInterfaceEntry | .1.3.6.1.4.1.3478.6.1.1.2.1.1 | |
| cNetworkInterfaceIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.1.2.1.1.1 |
| cNetworkInterfaceMACAddressOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.10 |
| cNetworkInterfaceMTUOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.1.2.1.1.11 |
| cNetworkInterfaceIDOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.2 |
| cNetworkInterfaceNameOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.3 |
| cNetworkInterfaceLinkStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.4 |
| cNetworkInterfaceIPAddress | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.5 |
| cNetworkInterfaceNetmask | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.6 |
| cNetworkInterfaceDefaultGateway | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.7 |
| cNetworkInterfaceDHCP | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.2.1.1.8 |
.1.3.6.1.4.1.3478.6.1.1.3 | ||
| cNTPTable | .1.3.6.1.4.1.3478.6.1.1.3.1 | |
| cNTPEntry | .1.3.6.1.4.1.3478.6.1.1.3.1.1 | |
| cNTPIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.1.3.1.1.1 |
| cNTPEnabled | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.1.3.1.1.2 |
| cNTPAddress1 | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.3.1.1.3 |
| cNTPAddress2 | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.3.1.1.4 |
| cNTPSynchronized | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.3.1.1.5 |
.1.3.6.1.4.1.3478.6.1.1.4 | ||
| cLogTable | .1.3.6.1.4.1.3478.6.1.1.4.1 | |
| cLogEntry | .1.3.6.1.4.1.3478.6.1.1.4.1.1 | |
| cLogIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.1.4.1.1.1 |
| cLogID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.1.4.1.1.2 |
| cLogCreationDate | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.3478.6.1.1.4.1.1.3 |
| cLogSize | KBytesKBytes | .1.3.6.1.4.1.3478.6.1.1.4.1.1.4 |
.1.3.6.1.4.1.3478.6.1.2 | ||
.1.3.6.1.4.1.3478.6.1.2.1 | ||
| cPoolTable | .1.3.6.1.4.1.3478.6.1.2.1.1 | |
| cPoolEntry | .1.3.6.1.4.1.3478.6.1.2.1.1.1 | |
| cPoolIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.1.1.1.1 |
| cPoolNumberOfDiskArrays | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.2.1.1.1.10 |
| cPoolStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.1.1.1.11 |
| cPoolHighWaterMark | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.2.1.1.1.12 |
| cPoolID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.1.1.1.2 |
| cPoolName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.1.1.1.3 |
| cPoolCreationDate | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.3478.6.1.2.1.1.1.4 |
| cPoolRawSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.1.1.1.5 |
| cPoolAvailableSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.1.1.1.6 |
| cPoolUsedSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.1.1.1.7 |
| cPoolOverheadSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.1.1.1.8 |
| cPoolProtectionLevel | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.1.1.1.9 |
.1.3.6.1.4.1.3478.6.1.2.2 | ||
| cVolumeTable | .1.3.6.1.4.1.3478.6.1.2.2.1 | |
| cVolumeEntry | .1.3.6.1.4.1.3478.6.1.2.2.1.1 | |
| cVolumeIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.2.1.1.1 |
| cVolumeCompressionEnabled | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.2.2.1.1.10 |
| cVolumeReadOnly | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.2.2.1.1.11 |
| cVolumeAtimeEnabled | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.2.2.1.1.12 |
| cVolumeID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.1.1.2 |
| cVolumeName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.1.1.3 |
| cVolumePoolID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.1.1.4 |
| cVolumePoolName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.1.1.5 |
| cVolumeCreationDate | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.3478.6.1.2.2.1.1.6 |
| cVolumeMaximumSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.2.1.1.7 |
| cVolumeMinimumSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.2.1.1.8 |
| cVolumeUsedSpace | GBytesGBytes | .1.3.6.1.4.1.3478.6.1.2.2.1.1.9 |
| cSnapshotTable | .1.3.6.1.4.1.3478.6.1.2.2.2 | |
| cSnapshotEntry | .1.3.6.1.4.1.3478.6.1.2.2.2.1 | |
| cSnapshotIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.2.2.1.1 |
| cSnapshotID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.2.1.2 |
| cSnapshotName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.2.1.3 |
| cSnapshotVolumeID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.2.1.4 |
| cSnapshotCreationDate | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.3478.6.1.2.2.2.1.5 |
| cSnapshotSize | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.2.2.2.1.6 |
| cSnapshotScheduleTable | .1.3.6.1.4.1.3478.6.1.2.2.3 | |
| cSnapshotScheduleEntry | .1.3.6.1.4.1.3478.6.1.2.2.3.1 | |
| cSnapshotScheduleIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.2.3.1.1 |
| cSnapshotScheduleID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.2 |
| cSnapshotScheduleName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.3 |
| cSnapshotScheduleVolumeID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.4 |
| cSnapshotScheduleMaximumNumberOfSnapshots | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.5 |
| cSnapshotScheduleCronString | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.6 |
| cSnapshotScheduleStartTime | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.7 |
| cSnapshotScheduleFrequency | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.8 |
| cSnapshotScheduleRepeatInterval | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.3.1.9 |
| cCIFSShareTable | .1.3.6.1.4.1.3478.6.1.2.2.4 | |
| cCIFSShareEntry | .1.3.6.1.4.1.3478.6.1.2.2.4.1 | |
| cCIFSShareIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.2.4.1.1 |
| cCIFSShareID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.4.1.2 |
| cCIFSShareName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.4.1.3 |
| cCIFSSharePath | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.4.1.4 |
| cCIFSShareReadOnly | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.4.1.5 |
| cNFSShareTable | .1.3.6.1.4.1.3478.6.1.2.2.5 | |
| cNFSShareEntry | .1.3.6.1.4.1.3478.6.1.2.2.5.1 | |
| cNFSShareIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.2.2.5.1.1 |
| cNFSShareID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.2 |
| cNFSShareMountPoint | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.3 |
| cNFSSharePath | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.4 |
| cNFSShareAccessControl | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.5 |
| cNFSShareAnonymousUUID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.6 |
| cNFSShareComment | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.2.2.5.1.7 |
.1.3.6.1.4.1.3478.6.1.3 | ||
| cNFSServiceTable | .1.3.6.1.4.1.3478.6.1.3.1 | |
| cNFSServiceEntry | .1.3.6.1.4.1.3478.6.1.3.1.1 | |
| cNFSServiceIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.3.1.1.1 |
| cNFSServiceID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.1.1.2 |
| cNFSServiceStatus | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.1.1.3 |
| cNFSServiceTcpEnabled | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.1.1.4 |
| cNFSServiceUdpEnabled | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.1.1.5 |
| cNFSServiceThreads | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.3.1.1.6 |
| cADServiceTable | .1.3.6.1.4.1.3478.6.1.3.2 | |
| cADServiceEntry | .1.3.6.1.4.1.3478.6.1.3.2.1 | |
| cADServiceIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.3.2.1.1 |
| cADServiceID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.2.1.2 |
| cADServiceStatus | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.2.1.3 |
| cADServiceActiveDirectoryJoined | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.3.2.1.4 |
| cADServiceHostname | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.2.1.5 |
| cADServiceDnsDomainName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.2.1.6 |
.1.3.6.1.4.1.3478.6.1.3.3 | ||
| cSNMPClientTable | .1.3.6.1.4.1.3478.6.1.3.3.1 | |
| cSNMPClientEntry | .1.3.6.1.4.1.3478.6.1.3.3.1.1 | |
| cSNMPClientIndex | Integer32 | .1.3.6.1.4.1.3478.6.1.3.3.1.1.1 |
| cSNMPClientHost | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.3.1.1.2 |
| cSNMPClientNotifications | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3478.6.1.3.3.1.1.3 |
| cSNMPClientPort | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.1.3.3.1.1.4 |
| cSNMPClientCommunityString | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.1.3.3.1.1.5 |
.1.3.6.1.4.1.3478.6.2 | ||
.1.3.6.1.4.1.3478.6.2.1 | ||
| sChassisTable | .1.3.6.1.4.1.3478.6.2.1.1 | |
| sChassisEntry | .1.3.6.1.4.1.3478.6.2.1.1.1 | |
| sChassisIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.1.1.1 |
| sChassisID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.1.1.2 |
| sChassisType | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.1.1.3 |
| sChassisStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.1.1.4 |
| sChassisModelOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.1.1.5 |
| sChassisSerialNumberOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.1.1.6 |
| sChassisMemory | GBytesGBytes | .1.3.6.1.4.1.3478.6.2.1.1.1.7 |
| sChassisRawCapacity | GBytesGBytes | .1.3.6.1.4.1.3478.6.2.1.1.1.8 |
| sCPUTable | .1.3.6.1.4.1.3478.6.2.1.2 | |
| sCPUEntry | .1.3.6.1.4.1.3478.6.2.1.2.1 | |
| sCPUIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.2.1.1 |
| sCPUChassisID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.2.1.2 |
| sCPUSlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.2.1.3 |
| sCPUStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.2.1.4 |
| sCPUTemperatureOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.2.1.5 |
| sBootDriveTable | .1.3.6.1.4.1.3478.6.2.1.3 | |
| sBootDriveEntry | .1.3.6.1.4.1.3478.6.2.1.3.1 | |
| sBootDriveIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.3.1.1 |
| sBootDriveChassisID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.3.1.2 |
| sBootDriveSlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.3.1.3 |
| sBootDriveStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.3.1.4 |
| sBootDriveManufacturer | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.3.1.5 |
| sBootDriveModel | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.3.1.6 |
| sBootDriveSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.2.1.3.1.7 |
| sBootDriveSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.3.1.8 |
| sDataDriveTable | .1.3.6.1.4.1.3478.6.2.1.4 | |
| sDataDriveEntry | .1.3.6.1.4.1.3478.6.2.1.4.1 | |
| sDataDriveIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.4.1.1 |
| sDataDriveChassis | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.4.1.2 |
| sDataDriveSlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.4.1.3 |
| sDataDriveStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.4.1.4 |
| sDataDriveSize | GBytesGBytes | .1.3.6.1.4.1.3478.6.2.1.4.1.5 |
| sDataDriveSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.4.1.6 |
| sDataDrivePoolID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.4.1.7 |
| sDataDrivePoolName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.4.1.8 |
| sFanTable | .1.3.6.1.4.1.3478.6.2.1.5 | |
| sFanEntry | .1.3.6.1.4.1.3478.6.2.1.5.1 | |
| sFanIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.5.1.1 |
| sFanChassisID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.5.1.2 |
| sFanSlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.5.1.3 |
| sFanStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.5.1.4 |
| sFanSpeedOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.5.1.5 |
| sPowerSupplyTable | .1.3.6.1.4.1.3478.6.2.1.7 | |
| sPowerSupplyEntry | .1.3.6.1.4.1.3478.6.2.1.7.1 | |
| sPowerSupplyIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.7.1.1 |
| sPowerSupplyChassisID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.7.1.2 |
| sPowerSupplySlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.7.1.3 |
| sPowerSupplyStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.7.1.4 |
| sPowerSupplyWattsOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.2.1.7.1.5 |
| sTapeDriveTable | .1.3.6.1.4.1.3478.6.2.1.8 | |
| sTapeDriveEntry | .1.3.6.1.4.1.3478.6.2.1.8.1 | |
| sTapeDriveIndex | Integer32 | .1.3.6.1.4.1.3478.6.2.1.8.1.1 |
| sTapeDrivePartition | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.2 |
| sTapeDriveStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.3 |
| sTapeDriveType | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.4 |
| sTapeDriveSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.5 |
| sTapeDriveTapeBarcode | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.6 |
| sTapeDriveErrorMesssage | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.2.1.8.1.7 |
.1.3.6.1.4.1.3478.6.3 | ||
.1.3.6.1.4.1.3478.6.3.1 | ||
| pPoolStatisticsTable | .1.3.6.1.4.1.3478.6.3.1.1 | |
| pPoolStatisticsEntry | .1.3.6.1.4.1.3478.6.3.1.1.1 | |
| pPoolStatisticsIndex | Integer32 | .1.3.6.1.4.1.3478.6.3.1.1.1.1 |
| pPoolStatisticsPoolID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.2 |
| pPoolStatisticsPoolName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.3 |
| pPoolStatisticsCollectionTime | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.4 |
| pPoolStatisticsReadIOPs | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.5 |
| pPoolStatisticsWriteIOPs | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.6 |
| pPoolStatisticsReadBytesPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.7 |
| pPoolStatisticsWriteBytesPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.1.1.1.8 |
.1.3.6.1.4.1.3478.6.3.2 | ||
| pDataDriveStatisticsTable | .1.3.6.1.4.1.3478.6.3.2.1 | |
| pDataDriveStatisticsEntry | .1.3.6.1.4.1.3478.6.3.2.1.1 | |
| pDataDriveStatisticsIndex | Integer32 | .1.3.6.1.4.1.3478.6.3.2.1.1.1 |
| pDataDriveStatisticsReadLatencyInMilliseconds | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.10 |
| pDataDriveStatisticsWriteLatencyInMilliseconds | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.11 |
| pDataDriveStatisticsCaseID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.2 |
| pDataDriveStatisticsCaseSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.3 |
| pDataDriveStatisticsCaseType | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.4 |
| pDataDriveStatisticsDataDriveID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.5 |
| pDataDriveStatisticsDataDriveSlot | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3478.6.3.2.1.1.6 |
| pDataDriveStatisticsCollectionTime | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.7 |
| pDataDriveStatisticsReadMBPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.8 |
| pDataDriveStatisticsWriteMBPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.2.1.1.9 |
.1.3.6.1.4.1.3478.6.3.3 | ||
| pCPUStatisticsTable | .1.3.6.1.4.1.3478.6.3.3.1 | |
| pCPUStatisticsEntry | .1.3.6.1.4.1.3478.6.3.3.1.1 | |
| pCPUStatisticsIndex | Integer32 | .1.3.6.1.4.1.3478.6.3.3.1.1.1 |
| pCPUStatisticsServerID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.3.1.1.2 |
| pCPUStatisticsServerSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.3.1.1.3 |
| pCPUStatisticsCollectionTime | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.3.1.1.4 |
| pCPUStatisticsIdlePercent | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.3.1.1.5 |
| pCPUStatisticsUtilizationPercentOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.3.1.1.6 |
.1.3.6.1.4.1.3478.6.3.4 | ||
| pNetworkStatisticsTable | .1.3.6.1.4.1.3478.6.3.4.1 | |
| pNetworkStatisticsEntry | .1.3.6.1.4.1.3478.6.3.4.1.1 | |
| pNetworkStatisticsIndexOBS ✓ | Integer32 | .1.3.6.1.4.1.3478.6.3.4.1.1.1 |
| pNetworkStatisticsErrorsOutOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.10 |
| pNetworkStatisticsDropsInOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.11 |
| pNetworkStatisticsCollisionsOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.12 |
| pNetworkStatisticsInterfaceID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.2 |
| pNetworkStatisticsLinkStatusOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.3 |
| pNetworkStatisticsCollectionTimeOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.4 |
| pNetworkStatisticsBytesInOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.5 |
| pNetworkStatisticsBytesOutOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.6 |
| pNetworkStatisticsPacketsInOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.7 |
| pNetworkStatisticsPacketsOutOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.8 |
| pNetworkStatisticsErrorsInOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.4.1.1.9 |
.1.3.6.1.4.1.3478.6.3.5 | ||
| pTapeDriveStatisticsTable | .1.3.6.1.4.1.3478.6.3.5.1 | |
| pTapeDriveStatisticsEntry | .1.3.6.1.4.1.3478.6.3.5.1.1 | |
| pTapeDriveStatisticsIndex | Integer32 | .1.3.6.1.4.1.3478.6.3.5.1.1.1 |
| pTapeDriveStatisticsTapeDriveID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.2 |
| pTapeDriveStatisticsTapeDriveSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.3 |
| pTapeDriveStatisticsCollectionTime | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.4 |
| pTapeDriveStatisticsReadMBPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.5 |
| pTapeDriveStatisticsWriteMBPerSecond | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.6 |
| pTapeDriveStatisticsReadLatencyInMilliseconds | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.7 |
| pTapeDriveStatisticsWriteLatencyInMilliseconds | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3478.6.3.5.1.1.8 |
.1.3.6.1.4.1.3478.6.4 | ||
.1.3.6.1.4.1.3478.6.4.1 | ||
| eventSeverity | SpectraLogicStrataEventSeverity | .1.3.6.1.4.1.3478.6.4.1.1 |
| eventTimestamp | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.3478.6.4.1.2 |
.1.3.6.1.4.1.3478.6.4.2 |
Notifications / Traps (11)
| Notification | Variable bindings | OID |
|---|---|---|
| nCPUStatus | .1.3.6.1.4.1.3478.6.4.2.1 | |
| nUsbStatus | .1.3.6.1.4.1.3478.6.4.2.10 | |
| nBootDriveLifespan | .1.3.6.1.4.1.3478.6.4.2.11 | |
| nNetworkInterfaceStatus | .1.3.6.1.4.1.3478.6.4.2.13 | |
| nBootDriveStatus | .1.3.6.1.4.1.3478.6.4.2.2 | |
| nDataDriveStatus | .1.3.6.1.4.1.3478.6.4.2.3 | |
| nFanStatus | .1.3.6.1.4.1.3478.6.4.2.4 | |
| nPoolStatus | .1.3.6.1.4.1.3478.6.4.2.6 | |
| nPowerSupplyStatus | .1.3.6.1.4.1.3478.6.4.2.7 | |
| nScheduledASLSent | .1.3.6.1.4.1.3478.6.4.2.8 | |
| nHighWaterMarkStatus | .1.3.6.1.4.1.3478.6.4.2.9 |
Type Definitions (4)
| Type | Syntax | Constraints |
|---|---|---|
| GBytes | Integer32 | 1 constraints |
| KBytes | Integer32 | 1 constraints |
| MBytes | Integer32 | 1 constraints |
| SpectraLogicStrataEventSeverity | Enumeration | 5 values |
Dependencies (3) 3 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- SPECTRA-LOGIC-STRATA-MIBspectralogicselected