SNR-ERD-4

Monitored by Observium
        The MIB module for SNR-ERD-4
    
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors Status
Explore Observium network monitoring
Source file
SNR-ERD-4
Last revised
Identity
snr-erd-4
Base OID
1.3.6.1.4.1.40418.2.6
Imported Objects
RFC1155-SMI Counter enterprises IpAddress
RFC1213-MIB DisplayString
SNMPv2-CONF NOTIFICATION-GROUP (no object page)
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page)
Net-SNMP examples using the snr MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SNR-ERD-4' -M '/opt/observium/mibs/snr:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SNR-ERD-4::snr-erd-4'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SNR-ERD-4' -M '/opt/observium/mibs/snr:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SNR-ERD-4::snr-erd-4'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (51)
7 directly used by Observium
snr
.1.3.6.1.4.1.40418
.1.3.6.1.4.1.40418.2
.1.3.6.1.4.1.40418.2.6
.1.3.6.1.4.1.40418.2.6.0
.1.3.6.1.4.1.40418.2.6.1
.1.3.6.1.4.1.40418.2.6.1.1
adcSensor OBS ✓
Volt DCInteger32
.1.3.6.1.4.1.40418.2.6.1.2
sp
.1.3.6.1.4.1.40418.2.6.1.30
.1.3.6.1.4.1.40418.2.6.1.50
.1.3.6.1.4.1.40418.2.6.1.50.2
temperatureDHT OBS ✓
degrees CentigradeInteger32
.1.3.6.1.4.1.40418.2.6.1.8
humidityDHT OBS ✓
.1.3.6.1.4.1.40418.2.6.1.9
.1.3.6.1.4.1.40418.2.6.10
dataType r/w
Enumeration
.1.3.6.1.4.1.40418.2.6.10.1
.1.3.6.1.4.1.40418.2.6.10.10
humCrit r/w
.1.3.6.1.4.1.40418.2.6.10.10.20
Volt DCInteger32
.1.3.6.1.4.1.40418.2.6.10.10.30
Volt DCInteger32
.1.3.6.1.4.1.40418.2.6.10.10.31
.1.3.6.1.4.1.40418.2.6.10.10.35
reboot r/w
.1.3.6.1.4.1.40418.2.6.10.300
.1.3.6.1.4.1.40418.2.6.11
.1.3.6.1.4.1.40418.2.6.11.1
statusUPS OBS ✓
Enumeration
.1.3.6.1.4.1.40418.2.6.11.1.1
.1.3.6.1.4.1.40418.2.6.11.1.10
lastBatteryChangeUPS OBS ✓ r/w
OctetString
.1.3.6.1.4.1.40418.2.6.11.1.20
.1.3.6.1.4.1.40418.2.6.11.1.51
.1.3.6.1.4.1.40418.2.6.11.1.52
Enumeration
.1.3.6.1.4.1.40418.2.6.11.1.53
Enumeration
.1.3.6.1.4.1.40418.2.6.11.1.54
.1.3.6.1.4.1.40418.2.6.11.1.71
.1.3.6.1.4.1.40418.2.6.11.1.8
pid
.1.3.6.1.4.1.40418.2.6.11.10
inputPID r/w
.1.3.6.1.4.1.40418.2.6.11.10.1
.1.3.6.1.4.1.40418.2.6.11.10.2
.1.3.6.1.4.1.40418.2.6.11.10.3
.1.3.6.1.4.1.40418.2.6.11.10.4
.1.3.6.1.4.1.40418.2.6.11.10.5
.1.3.6.1.4.1.40418.2.6.11.10.6
.1.3.6.1.4.1.40418.2.6.11.10.7
dio
.1.3.6.1.4.1.40418.2.6.2
Enumeration
.1.3.6.1.4.1.40418.2.6.2.3
.1.3.6.1.4.1.40418.2.6.4
.1.3.6.1.4.1.40418.2.6.4.1
.1.3.6.1.4.1.40418.2.6.4.1.2
.1.3.6.1.4.1.40418.2.6.4.2
.1.3.6.1.4.1.40418.2.6.4.2.2
.1.3.6.1.4.1.40418.2.6.5
gsm
.1.3.6.1.4.1.40418.2.6.5.1
gsmReconnCount OBS ✓
.1.3.6.1.4.1.40418.2.6.5.1.10
gsmStrength OBS ✓
.1.3.6.1.4.1.40418.2.6.5.1.2
rf
.1.3.6.1.4.1.40418.2.6.5.2
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC1155-SMIrfc
  2. SNMPv2-SMIrfc
  3. SNMPv2-TCrfc
  4. IANAifType-MIBrfc
  5. RFC-1212rfc
  6. RFC1213-MIBrfc
  7. SNMPv2-CONFrfc
  8. SNR-ERD-4snrselected
Type Definitions (1)
Unsigned32 range: 0..4294967295
Conformance Groups (1)
DI1Alarm (unresolved reference) DI1Release (unresolved reference) DI2Alarm (unresolved reference) DI2Release (unresolved reference) DI3Alarm (unresolved reference) DI3Release (unresolved reference) DI4Alarm (unresolved reference) DI4Release (unresolved reference) DI5Alarm (unresolved reference) DI5Release (unresolved reference) uSenseAlarm uSenseRelease reloutOn reloutOff DO1On (unresolved reference) DO1Off (unresolved reference) DO2On (unresolved reference) DO2Off (unresolved reference) DO3On (unresolved reference) DO3Off (unresolved reference) DO4On (unresolved reference) DO4Off (unresolved reference) DO5On (unresolved reference) DO5Off (unresolved reference) tempSensorAlarm tempSensorRelease adcSensorAlarm adcSensorRelease humSensorAlarm humSensorRelease task1Done task2Done task3Done task4Done pingLost batteryChargeLow upsUtilityFail upsUtilityOk
Notifications
.1.3.6.1.4.1.40418.2.6.99
Notifications / Traps (18)
NameOIDDescription
.1.3.6.1.4.1.40418.2.6.0.11
Signifies that Phase sensor Alarm fires
.1.3.6.1.4.1.40418.2.6.0.12
Signifies that Phase sensor Alarm released
.1.3.6.1.4.1.40418.2.6.0.13
Signifies that Rele was swithed on by Thermostat or Gigrostat mode
.1.3.6.1.4.1.40418.2.6.0.14
Signifies that Rele was swithed off by Thermostat or Gigrostat mode
.1.3.6.1.4.1.40418.2.6.0.29
Temperature alarm
.1.3.6.1.4.1.40418.2.6.0.30
Temperature release
.1.3.6.1.4.1.40418.2.6.0.31
Voltage sensor alarm
.1.3.6.1.4.1.40418.2.6.0.32
Voltage sensor release
.1.3.6.1.4.1.40418.2.6.0.33
Humidity alarm
.1.3.6.1.4.1.40418.2.6.0.34
Humidity release
.1.3.6.1.4.1.40418.2.6.0.36
Task 1 done
.1.3.6.1.4.1.40418.2.6.0.37
Task 2 done
.1.3.6.1.4.1.40418.2.6.0.38
Task 3 done
.1.3.6.1.4.1.40418.2.6.0.39
Task 4 done
.1.3.6.1.4.1.40418.2.6.0.45
Ping lost
.1.3.6.1.4.1.40418.2.6.0.47
Battery charge is low
.1.3.6.1.4.1.40418.2.6.0.50
UPS utility fail
.1.3.6.1.4.1.40418.2.6.0.51
UPS utility OK