SL-EVENT-MIB

        This MIB module describes the configuration change and inventory events.
    
Source file
SL-EVENT-MIB
Last revised
Identity
slEventMib
Base OID
1.3.6.1.4.1.4515.1.3.22
Imported Objects
IF-MIB InterfaceIndex
PerfHist-TC-MIB PerfCurrentCount PerfIntervalCount PerfTotalCount
SL-MAIN-MIB slMain slmTrapLogId
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page) TimeStamp TruthValue
Net-SNMP examples using the packetlight MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SL-EVENT-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SL-EVENT-MIB::slEventMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SL-EVENT-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-EVENT-MIB::slEventMib'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (27)
.1.3.6.1.4.1.4515.1.3.22
.1.3.6.1.4.1.4515.1.3.22.1
.1.3.6.1.4.1.4515.1.3.22.1.1
.1.3.6.1.4.1.4515.1.3.22.1.1.1
.1.3.6.1.4.1.4515.1.3.22.1.1.1.1
.1.3.6.1.4.1.4515.1.3.22.1.1.1.2
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.1.1.3
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.1.1.4
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.1.1.5
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.1.1.6
.1.3.6.1.4.1.4515.1.3.22.1.2
.1.3.6.1.4.1.4515.1.3.22.1.2.1
.1.3.6.1.4.1.4515.1.3.22.1.2.1.1
.1.3.6.1.4.1.4515.1.3.22.1.2.1.2
.1.3.6.1.4.1.4515.1.3.22.1.2.1.3
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.2.1.4
.1.3.6.1.4.1.4515.1.3.22.1.2.1.5
.1.3.6.1.4.1.4515.1.3.22.1.3
.1.3.6.1.4.1.4515.1.3.22.1.3.1
.1.3.6.1.4.1.4515.1.3.22.1.3.1.1
.1.3.6.1.4.1.4515.1.3.22.1.3.1.2
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.3.1.3
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.3.1.4
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.3.1.5
OctetString
.1.3.6.1.4.1.4515.1.3.22.1.3.1.6
.1.3.6.1.4.1.4515.1.3.22.2
.1.3.6.1.4.1.4515.1.3.22.2.0
Dependencies (9) 6 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-TCrfc
  3. IANAifType-MIBrfc
  4. SNMPv2-CONFrfc
  5. SNMPv2-MIBrfc
  6. IF-MIBrfc
  7. PerfHist-TC-MIBrfc
  8. SL-NE-MIBpacketlight
  9. SL-MAIN-MIBpacketlight
  10. SL-EVENT-MIBpacketlightselected
Type Definitions (4)
Enumeration
inserted(1)
removed(2)
Enumeration
psu(1)
optics(2)
fan(3)
Enumeration
edDate(1)
rstProv(2)
edIp(3)
initPm(4)
dltIpRoute(5)
edSys(6)
setSid(7)
addUser(8)
dltUser(9)
rmvFac(10)
rstFac(11)
edFac(12)
oprLoopback(13)
rlsLoopback(14)
entAps(15)
dltAps(16)
oprProtSw(17)
rlsProtSw(18)
oprAco(19)
rstProvCommit(20)
savProvStart(21)
savProvComplete(22)
savProvFailed(23)
swLoadUpgrade(24)
Enumeration
swUpgradeEvent(1)
remoteUnitFailEvent(2)
alsOperStatus(3)
opticalPowerDrop(4)
userLoginLogout(5)
Notifications / Traps (6)
NameOIDDescription
.1.3.6.1.4.1.4515.1.3.22.2.0.2
An slEventTrap notification is sent when an configuration change occures.
It is defined to support browsers that don't recognize RFC 2576.
.1.3.6.1.4.1.4515.1.3.22.2.0.3
An slInventoryEventTrap notification is sent when the node inventory is changed.]
It is defined to support browsers that don't recognize RFC 2576.
.1.3.6.1.4.1.4515.1.3.22.2.0.4
An slEventTrap notification is sent when an configuration change occures.
It is defined to support browsers that don't recognize RFC 2576.
.1.3.6.1.4.1.4515.1.3.22.2.2
An slEventTrap notification is sent when an configuration change occures.
.1.3.6.1.4.1.4515.1.3.22.2.3
An slInventoryEventTrap notification is sent when the node inventory is changed.
.1.3.6.1.4.1.4515.1.3.22.2.4
An slEventTrap notification is sent when an configuration change occures.