SL-ALS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
10
.1.3.6.1.4.1.4515.1.12.1.1 · 1 row entry · 10 columns
The ALS configuration Table.
slAlsConfigEntry entry .1.3.6.1.4.1.4515.1.12.1.1.1
The entries exist for active optical inetfaces
ifType = 196. The objects in this table are
used to configure the ALS algorithm.
Indexes
IF-MIBifIndex
Column Syntax OID
slAlsMode
Enable/Disable the ALS algorithm.
When the Laser Admin Status is 'down' the ALS not operational.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.4515.1.12.1.1.1.1
slAlsLosDeclareTime
Time to declare optical LOS present or clear
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.12.1.1.1.2
slAlsTestPulseTime
Manual restart for test Pulse time (in manual restart) - 90+-10 sec.
Enumerationr/w
Enumerated Values:
1s80
2s90
3s100
.1.3.6.1.4.1.4515.1.12.1.1.1.3
slAlsManualPulseTime
Manual restart Pulse time (in manual mode):
(1), -- 1.75 Sec
(2), -- 2.0 sec (default)
(3), -- 2.25 sec
(i > 3) -- (i) *500ms
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.12.1.1.1.4
slAlsAutomaticPulseTime
Automatic restart Pulse time (in automatic mode):
(1), -- 1.75 Sec
(2), -- 2.0 sec (default)
(3), -- 2.25 sec
(i > 3) -- (i) *500ms
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.12.1.1.1.5
slAlsAutomaticDelayTime
In Automatic mode. The delay between two laser re-activations.
Integer32r/w
Constraints:
range: 0-300
.1.3.6.1.4.1.4515.1.12.1.1.1.6
slAlsLaserTestActivate
Activate the laser for test operation.
Enumerationr/w
Enumerated Values:
1activate
.1.3.6.1.4.1.4515.1.12.1.1.1.7
slAlsLaserManualActivate
Activate the laser manual operation.
Enumerationr/w
Enumerated Values:
1activate
.1.3.6.1.4.1.4515.1.12.1.1.1.8
slAlsOperStatus
The operational status of the ALS algorithm.
When the Laser Admin Status is 'down' the ALS not operational.
Enumeration
Enumerated Values:
1active
2inactive
.1.3.6.1.4.1.4515.1.12.1.1.1.9
slAlsResetParams
Setting this variable to 1 will reset the ALS
parameters to the factory defaults.
Enumerationr/w
Enumerated Values:
1resetCounters
.1.3.6.1.4.1.4515.1.12.1.1.1.10