SIAE-CARRIER-AGGRL1-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
15
carrierAggrSensorTable
table.1.3.6.1.4.1.3373.1103.104.2
·
1 row entry
·
9 columns
Uses the siaemic variant from
Command help
/opt/observium/mibs/siaemic.
Walk carrierAggrSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SIAE-CARRIER-AGGRL1-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-CARRIER-AGGRL1-MIB::carrierAggrSensorTable'
Table with Radio(s) interface(s) that can be associated to an entry of carrierAggrActuatorTable.
A row in the carrierAggrSensorTable.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object identifies the index of carrierAggrSensorTable.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.3373.1103.104.2.1.1 |
||||||||||||
|
The status of this sensor entry.
An entry may not exist in the active state unless all objects in the entry have an appropriate value: SensorIfIndex must be set to a valid ifIndex number. Otherwise, the e… |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.6.1.4.1.3373.1103.104.2.1.2 |
||||||||||||
|
Administative status of the sensor.
The value down(1) turns off all actuators associated with this sensor. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.2.1.3 |
||||||||||||
|
This object accepts a greater than zero value to identify an
interface in ifTable. Some parameters of the radio associated to this interface is monitored and a notification is sent to all connected actuators. |
IF-MIBInterfaceIndexOrZeror/w Type Constraints: range: 0..2147483647Description: This textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits… |
.1.3.6.1.4.1.3373.1103.104.2.1.4 |
||||||||||||
|
This capability is related to
HITLESS Behaviour carrierAggrSensorHitlessBehaviour. |
Bits Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.2.1.5 |
||||||||||||
|
The hitless behaviour. When enabled, data related to the current ACM zone
is notified to an external N.E. aggregator, so it can dynamically exclude/include the data-flow without loss of frames. It can be enabled only… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.2.1.6 |
||||||||||||
|
The policy to select the hitless profile (i.e. the lowest one under
which a N.E. aggregator excludes the carrier from an existing aggregation). auto(1): Tx Lower Profile + 1 is selected; manual(2): the value set in car… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.2.1.7 |
||||||||||||
|
The hitless profile in case of carrierHyAggrHitlessBehaviour
set as enabled and carrierHyAggrHitlessMode set as manual. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3373.1103.104.2.1.8 |
||||||||||||
|
The working zone of the radio link.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.2.1.9 |
carrierAggrActuatorTable
table.1.3.6.1.4.1.3373.1103.104.3
·
1 row entry
·
6 columns
Uses the siaemic variant from
Command help
/opt/observium/mibs/siaemic.
Walk carrierAggrActuatorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SIAE-CARRIER-AGGRL1-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-CARRIER-AGGRL1-MIB::carrierAggrActuatorTable'
Table with Lan(s) interface that can be associated to an entry of carrierAggrSensorTable.
A row in the carrierAggrActuatorTable.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object identifies the carrier aggr Actuator inside the
Network Element. |
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.3373.1103.104.3.1.1 |
||||||||||||
|
The status of this entry.
An entry may not exist in the active state unless all objects in the entry have an appropriate value: carrierAggrActuatorIfIndex must be set to a valid ifIndex number and carrier… |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.6.1.4.1.3373.1103.104.3.1.2 |
||||||||||||
|
Administative status of the actuator. The value down(1) turns it off.
Other actuators associated with the same sensor remain active. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3373.1103.104.3.1.3 |
||||||||||||
|
This object accepts a greater than zero value to identify an
interface in ifTable. The notify received from the connected sensor is forwarded to the remote aggregator to signal some anomalies on this aggregated flow. |
IF-MIBInterfaceIndexOrZeror/w Type Constraints: range: 0..2147483647Description: This textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits… |
.1.3.6.1.4.1.3373.1103.104.3.1.4 |
||||||||||||
|
This object connects this actuator to a sensor.
|
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3373.1103.104.3.1.5 |
||||||||||||
|
This object is used to contain
the Ip address of the equipment connected with this Lan (the concatenator unit) |
SNMPv2-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.3373.1103.104.3.1.6 |