SCTE-HMS-HE-POWER-SUPPLY-MIB
The MIB module is for representing a power supply present in the
headend (or indoor) and supported by a SNMP agent.
- Source file
SCTE-HMS-HE-POWER-SUPPLY-MIB- Last revised
- Identity
hePowerSupplyMIB- Base OID
1.3.6.1.4.1.5591.1.11.2.2.1
Imported Objects
| ENTITY-MIB | entPhysicalIndex |
| SCTE-HMS-HEADENDIDENT-MIB | HeHundredthWatts HeMilliAmp hePowerSupply HeTenthVolt |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DisplayString |
Net-SNMP examples using the scte MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SCTE-HMS-HE-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SCTE-HMS-HE-POWER-SUPPLY-MIB::hePowerSupplyMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-POWER-SUPPLY-MIB::hePowerSupplyMIB'
Objects (17)
Showing 17 of 17 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.5591.1.11.2.2.1 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.1 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1.1 |
||
|
milliamperesSCTE-HMS-HEADENDIDENT-MIBHeMilliAmp
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1.1.1 |
|
|
hundredths of a wattSCTE-HMS-HEADENDIDENT-MIBHeHundredthWatts
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1.1.2 |
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1.1.3 |
||
|
tenths of a voltSCTE-HMS-HEADENDIDENT-MIBHeTenthVolt
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.1.1.4 |
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2.1 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2.1.1 |
||
|
tenths of a voltSCTE-HMS-HEADENDIDENT-MIBHeTenthVolt
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2.1.2 |
|
|
milliamperesSCTE-HMS-HEADENDIDENT-MIBHeMilliAmp
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2.1.3 |
|
|
hundredths of a wattSCTE-HMS-HEADENDIDENT-MIBHeHundredthWatts
|
.1.3.6.1.4.1.5591.1.11.2.2.1.1.2.1.4 |
|
.1.3.6.1.4.1.5591.1.11.2.2.1.2 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.2.1 |
||
.1.3.6.1.4.1.5591.1.11.2.2.1.2.2 |
Dependencies (11) 5 direct · 6 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANA-ENTITY-MIBrfc
- SNMPv2-CONFrfc
- SNMP-FRAMEWORK-MIBrfc
- UUID-TC-MIBrfc
- ENTITY-MIBrfc
- RFC1155-SMIrfc
- SCTE-ROOTscte
- SCTE-HMS-ROOTSscte
- SCTE-HMS-HEADENDIDENT-MIBscte
- SCTE-HMS-HE-POWER-SUPPLY-MIBscteselected
Conformance Groups (3)
|
A mandatory collection of objects that provide information
applicable to a particular power supply's output parameters. |
.1.3.6.1.4.1.5591.1.11.2.2.1.2.2.1
|
|
|
A collection of objects that provide information applicable to a
particular power supply's input parameters. |
.1.3.6.1.4.1.5591.1.11.2.2.1.2.2.2
|
|
|
A collection of objects that provide information applicable to a
particular power supply's output parameters. |
.1.3.6.1.4.1.5591.1.11.2.2.1.2.2.3
|
Compliance Statements (1)
OID
.1.3.6.1.4.1.5591.1.11.2.2.1.2.1.1The minimum compliance statement for indoor power supplies.
Required groups
| mandatory | hePsOutputMandatoryGroup | |
| optional | hePsUnitGroup | The hePsUnitGroup is unconditionally optional. |
| optional | hePsOutputGroup | The hePsOutputGroup is unconditionally optional. |