SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
17
heOpTxUnitTable
table.1.3.6.1.4.1.5591.1.11.1.1.1.1.1
·
1 row entry
·
2 columns
Uses the scte variant from
Command help
/opt/observium/mibs/scte.
Walk heOpTxUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxUnitTable'
A table containing information about headend (or indoor) fiber optic transmitters. These transmitters could be plug-in modules for a chassis, stand-alone pizza-box units etc.
Information about each Fiber Optic Transmitter in
the subsystem.
the subsystem.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
The output status of the transmitter.
If all the outputs of the transmitter are off then the variable value shall be off(1), else the value shall be on(2). |
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus Type Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.1 |
||||||
|
This variable controls the output status of the transmitter.
Setting this variable to off(1) will cause all the transmitters outputs to be shut off. Setting this variable to on(2) will c… |
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w Type Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.2 |
heOpTxInputTable
table.1.3.6.1.4.1.5591.1.11.1.1.1.1.2
·
1 row entry
·
6 columns
Uses the scte variant from
Command help
/opt/observium/mibs/scte.
Walk heOpTxInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxInputTable'
A table containing information related to RF Parameters in headend (or indoor) fiber optic transmitters. These transmitters could be plug-in modules for a chassis, stand-alone pizza-box units etc.
Information about each Fiber Optic Transmitter in
the subsystem.
the subsystem.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index number corresponding to the RF Input
for the transmitter unit. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.1 |
||||
|
RF composite input power in 0.1 dBm.
|
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm | .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.2 |
||||
|
Modulation Bias.
|
0.1 VoltSCTE-HMS-HEADENDIDENT-MIBHeTenthVolt | .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.3 |
||||
|
Switches the transmitter Automatic Gain Control mode
of operation either off(1) or on(2). |
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatusr/w Type Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.4 |
||||
|
Transmitter modulation mode:
cw(1) for Continuous Wave, or modulated(2) for Modulated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.5 |
||||
|
RF Pad Attenuation Level.
|
0.1 dBSCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w | .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.6 |
heOpTxLaserTable
table.1.3.6.1.4.1.5591.1.11.1.1.1.1.3
·
1 row entry
·
9 columns
Uses the scte variant from
Command help
/opt/observium/mibs/scte.
Walk heOpTxLaserTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxLaserTable'
A table containing information about transmitter laser(s).
A list of information about each laser in
the particular transmitter.
the particular transmitter.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
An arbitrary value which uniquely identifies the laser.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.1 |
||||||
|
Temperature of the Transmitter Laser.
This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An al… |
0.1 degrees CelsiusInteger32 Constraints: range: -250-1000 |
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.2 |
||||||
|
Transmitter laser bias current.
This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm sh… |
milli AmperesInteger32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.3 |
||||||
|
The laser output power.
This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm shall be r… |
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm | .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4 |
||||||
|
Laser Thermo Electric Cooler current.
|
milli AmperesSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.5 |
||||||
|
Laser type.
|
SCTE-HMS-HEADENDIDENT-MIBHeLaserType | .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.6 |
||||||
|
The laser wavelength.
Typical value might be 155056 (1550.56 nm). |
0.01 nanometerSCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter | .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.7 |
||||||
|
The laser output status.
The value is on(2), if the Laser output is operating in normal condition The value is off(1), if the laser is either forced to turn off or shut due to an internal … |
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus Type Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8 |
||||||
|
This variable controls the output status of the laser.
Setting this variable to off(1) will cause the laser output to be shut off. Setting this variable to on(2) will cause the laser ou… |
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w Type Values:
|
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.9 |