SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
17
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1 · 1 row entry · 2 columns
A table containing information about headend (or indoor)
fiber optic transmitters. These transmitters could be plug-in
modules for a chassis, stand-alone pizza-box units etc.
heOpTxUnitEntry entry .1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1
Information about each Fiber Optic Transmitter in
the subsystem.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
heOpTxUnitOutputStatus
The output status of the transmitter.

If all the outputs of the transmitter are off then
the variable value shall be off(1), else the value
shall be on(2).
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus Enumeration
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.1
heOpTxUnitOnOffControl
This variable controls the output status of the transmitter.

Setting this variable to off(1) will cause all the
transmitters outputs to be shut off.

Setting this variable to on(2) will c…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl Enumeration
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.2
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2 · 1 row entry · 6 columns
A table containing information related to RF Parameters
in headend (or indoor) fiber optic transmitters. These 
transmitters could be plug-in modules for a chassis, 
stand-alone pizza-box units etc.
heOpTxInputEntry entry .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1
Information about each Fiber Optic Transmitter in
the subsystem.
Indexes
ENTITY-MIBentPhysicalIndex heOpTxInputIndex
Column Syntax OID
heOpTxInputIndex
Index number corresponding to the RF Input
for the transmitter unit.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.1
heOpTxInputRFPower
RF composite input power in 0.1 dBm.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthdBm Integer32
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.2
heOpTxInputModulatorBias
Modulation Bias.
0.1 VoltSCTE-HMS-HEADENDIDENT-MIBHeTenthVolt
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthVolt Integer32
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.3
heOpTxInputAGCMode
Switches the transmitter Automatic Gain Control mode
of operation either off(1) or on(2).
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatusr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus Enumeration
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.4
heOpTxInputModulationMode
Transmitter modulation mode:
cw(1) for Continuous Wave, or
modulated(2) for Modulated.
Enumerationr/w
Enumerated Values:
1cw
2modulated
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.5
heOpTxInputRFPadLevel
RF Pad Attenuation Level.
0.1 dBSCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthdB Integer32
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.6
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3 · 1 row entry · 9 columns
A table containing information about transmitter 
laser(s).
heOpTxLaserEntry entry .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1
A list of information about each laser in
the particular transmitter.
Indexes
ENTITY-MIBentPhysicalIndex heOpTxLaserIndex
Column Syntax OID
heOpTxLaserIndex
An arbitrary value which uniquely identifies the laser.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.1
heOpTxLaserTemp
Temperature of the Transmitter Laser.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An al…
0.1 degrees CelsiusInteger32
Constraints:
range: -250-1000
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.2
heOpTxLaserBiasCurrent
Transmitter laser bias current.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An alarm sh…
milli AmperesInteger32
Constraints:
range: 0-65535
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.3
heOpTxLaserOutputPower
The laser output power.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An alarm shall be r…
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthdBm Integer32
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4
heOpTxLaserTECCurrent
Laser Thermo Electric Cooler current.
milli AmperesSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.5
heOpTxLaserType
Laser type.
SCTE-HMS-HEADENDIDENT-MIBHeLaserType
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeLaserType OctetString
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.6
heOpTxLaserWavelength
The laser wavelength.
Typical value might be 155056 (1550.56 nm).
0.01 nanometerSCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter Unsigned32
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.7
heOpTxLaserOutputStatus
The laser output status.

The value is on(2), if the Laser output is operating
in normal condition

The value is off(1), if the laser is either forced to turn off
or shut due to an internal …
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus Enumeration
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8
heOpTxLaserOnOffControl
This variable controls the output status of the laser.

Setting this variable to off(1) will cause the
laser output to be shut off.

Setting this variable to on(2) will cause the
laser ou…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl Enumeration
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.9