SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
17
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1 · 1 row entry · 2 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpTxUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxUnitTable'
A table containing information about headend (or indoor)
fiber optic transmitters. These transmitters could be plug-in
modules for a chassis, stand-alone pizza-box units etc.
heOpTxUnitEntry row .1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1
Information about each Fiber Optic Transmitter in
the subsystem.
Column Syntax OID
The output status of the transmitter.

If all the outputs of the transmitter are off then
the variable value shall be off(1), else the value
shall be on(2).
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.1
This variable controls the output status of the transmitter.

Setting this variable to off(1) will cause all the
transmitters outputs to be shut off.

Setting this variable to on(2) will c…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.2
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2 · 1 row entry · 6 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpTxInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxInputTable'
A table containing information related to RF Parameters
in headend (or indoor) fiber optic transmitters. These 
transmitters could be plug-in modules for a chassis, 
stand-alone pizza-box units etc.
heOpTxInputEntry row .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1
Information about each Fiber Optic Transmitter in
the subsystem.
Column Syntax OID
Index number corresponding to the RF Input
for the transmitter unit.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.1
RF composite input power in 0.1 dBm.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.2
Modulation Bias.
0.1 VoltSCTE-HMS-HEADENDIDENT-MIBHeTenthVolt .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.3
Switches the transmitter Automatic Gain Control mode
of operation either off(1) or on(2).
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatusr/w
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.4
Transmitter modulation mode:
cw(1) for Continuous Wave, or
modulated(2) for Modulated.
Enumerationr/w
Enumerated Values:
1cw
2modulated
.1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.5
RF Pad Attenuation Level.
0.1 dBSCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w .1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.6
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3 · 1 row entry · 9 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpTxLaserTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB::heOpTxLaserTable'
A table containing information about transmitter 
laser(s).
heOpTxLaserEntry row .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1
A list of information about each laser in
the particular transmitter.
Column Syntax OID
An arbitrary value which uniquely identifies the laser.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.1
Temperature of the Transmitter Laser.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An al…
0.1 degrees CelsiusInteger32
Constraints:
range: -250-1000
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.2
Transmitter laser bias current.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An alarm sh…
milli AmperesInteger32
Constraints:
range: 0-65535
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.3
The laser output power.

This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).

An alarm shall be r…
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4
Laser Thermo Electric Cooler current.
milli AmperesSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.5
Laser type.
SCTE-HMS-HEADENDIDENT-MIBHeLaserType .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.6
The laser wavelength.
Typical value might be 155056 (1550.56 nm).
0.01 nanometerSCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter .1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.7
The laser output status.

The value is on(2), if the Laser output is operating
in normal condition

The value is off(1), if the laser is either forced to turn off
or shut due to an internal …
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
Type Values:
1off
2on
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8
This variable controls the output status of the laser.

Setting this variable to off(1) will cause the
laser output to be shut off.

Setting this variable to on(2) will cause the
laser ou…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.9