rmConfigTrapsReceiversTable

table mandatory
.1.3.6.1.4.1.534.6.7.1.1.2.14 · 1 row entry · 5 columns
Uses the eaton variant from /opt/observium/mibs/eaton.
Command help
Walk rmConfigTrapsReceiversTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RackMonitor-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RackMonitor-MIB::rmConfigTrapsReceiversTable'
A list of managers to send traps to.  The number of
entries is given by the value of rmConfigNumTrapReceivers
rmConfigTrapsReceiversEntry row .1.3.6.1.4.1.534.6.7.1.1.2.14.1
The managers to send traps to.
Indexes
Column Syntax OID
trapsIndexmandatory
The index to a trap receiver entry.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.534.6.7.1.1.2.14.1.1
The IP address of the manager to send a trap to.
RFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.534.6.7.1.1.2.14.1.2
The community name to use in the trap when
sent to the manager.
OctetStringr/w
Constraints:
range: 0-19
.1.3.6.1.4.1.534.6.7.1.1.2.14.1.3
The severity level of traps to be received by this manager.
Enumerationr/w
Enumerated Values:
1informational
2warning
3severe
.1.3.6.1.4.1.534.6.7.1.1.2.14.1.4
Description of trap receivers
OctetStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.534.6.7.1.1.2.14.1.5

rmConfigAccessControlTable

table mandatory
.1.3.6.1.4.1.534.6.7.1.1.2.15 · 1 row entry · 4 columns
Uses the eaton variant from /opt/observium/mibs/eaton.
Command help
Walk rmConfigAccessControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RackMonitor-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RackMonitor-MIB::rmConfigAccessControlTable'
A list of managers which can access rm with private
community string.
rmConfigAccessControlEntry row .1.3.6.1.4.1.534.6.7.1.1.2.15.1
The managers.
Indexes
Column Syntax OID
accessIndexmandatory
The index to a access control entry.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.534.6.7.1.1.2.15.1.1
The IP address of the manager to access RackMonitor
RFC1155-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.534.6.7.1.1.2.15.1.2
The community name to use in the manager when
access RackMonitor
OctetStringr/w
Constraints:
range: 0-19
.1.3.6.1.4.1.534.6.7.1.1.2.15.1.3
Access type, only read/Write access type can change parameter
of RackMonitor
Enumerationr/w
Enumerated Values:
1readOnly
2read-write
3notAccess
.1.3.6.1.4.1.534.6.7.1.1.2.15.1.4

smSensorTable

table mandatory
.1.3.6.1.4.1.534.6.7.1.1.3.2 · 1 row entry · 8 columns
Uses the eaton variant from /opt/observium/mibs/eaton.
Command help
Walk smSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RackMonitor-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RackMonitor-MIB::smSensorTable'
A list of sensor devices to be monitored.
smSensorEntry row .1.3.6.1.4.1.534.6.7.1.1.3.2.1
The sensor device.
Indexes
Column Syntax OID
smDeviceIndexmandatory
The index to a sensor device entry.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.1
The device type plugged into RackMonitor.
Enumeration
Enumerated Values:
1unknow
2disabled
3eMD-HT
4eMD-T
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.2
The temperature of sensor on device RackMonitor, the unit is 0.1 degree.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.3
The status of temperature sensor on device RackMonitor.
Enumeration
Enumerated Values:
1unknow
2disabled
3normal
4lowWarning
5lowCritical
6highWarning
7highCritical
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.4
The humidity of sensor on device RackMonitor, the unit is 0.1%.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.5
The device type plugged into RackMonitor.
Enumeration
Enumerated Values:
1unknow
2disabled
3normal
4lowWarning
5lowCritical
6highWarning
7highCritical
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.6
smAlarm1mandatory
The device type plugged into RackMonitor.
Enumeration
Enumerated Values:
1unknow
2disabled
3active
4inactive
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.7
smAlarm2mandatory
The device type plugged into RackMonitor.
Enumeration
Enumerated Values:
1unknow
2disabled
3active
4inactive
.1.3.6.1.4.1.534.6.7.1.1.3.2.1.8

scSensorTable

table mandatory
.1.3.6.1.4.1.534.6.7.1.1.4.2 · 1 row entry · 3 columns
Uses the eaton variant from /opt/observium/mibs/eaton.
Command help
Walk scSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RackMonitor-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RackMonitor-MIB::scSensorTable'
A list of sensor devices to be configured.
scSensorEntry row .1.3.6.1.4.1.534.6.7.1.1.4.2.1
The sensor device.
Indexes
Column Syntax OID
scDeviceIndexmandatory
The index to a sensor device entry.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.534.6.7.1.1.4.2.1.1
scDeviceNamemandatory
The name of the sensor device for identification.
OctetStringr/w
Constraints:
range: 0-15
.1.3.6.1.4.1.534.6.7.1.1.4.2.1.2
scDeviceStatemandatory
The setup of sensor device type.
Enumerationr/w
Enumerated Values:
1disabled
2auto
.1.3.6.1.4.1.534.6.7.1.1.4.2.1.3