RAISECOM-OPTICAL-TRANSCEIVER-MIB
Monitored by Observium This MIB module defines objects to monitor optical
characteristics on the optical interfaces in a network element.
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
- Source file
RAISECOM-OPTICAL-TRANSCEIVER-MIB- Last revised
- Identity
raisecomOpticalTransceiver- Base OID
1.3.6.1.4.1.8886.1.18
Imported Objects
| IF-MIB | ifIndex |
| RAISECOM-BASE-MIB | raisecomAgent |
| RAISECOM-COMMON-MANAGEMENT-MIB | raisecomNotificationLocation |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION (no object page) TimeTicks |
Net-SNMP examples using the raisecom MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAISECOM-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAISECOM-OPTICAL-TRANSCEIVER-MIB::raisecomOpticalTransceiver'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-OPTICAL-TRANSCEIVER-MIB::raisecomOpticalTransceiver'
Objects (92)
10 directly used by Observium
Showing 92 of 92 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.8886.1.18 |
||
.1.3.6.1.4.1.8886.1.18.1 |
||
.1.3.6.1.4.1.8886.1.18.1.1 |
||
|
|
.1.3.6.1.4.1.8886.1.18.1.2 |
|
.1.3.6.1.4.1.8886.1.18.1.3 |
||
.1.3.6.1.4.1.8886.1.18.2 |
||
.1.3.6.1.4.1.8886.1.18.2.1 |
||
.1.3.6.1.4.1.8886.1.18.2.1.1 |
||
.1.3.6.1.4.1.8886.1.18.2.1.1.1 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.1 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.10 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.11 |
|
|
OctetString
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.12 |
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.13 |
||
.1.3.6.1.4.1.8886.1.18.2.1.1.1.14 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.15 |
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.16 |
||
.1.3.6.1.4.1.8886.1.18.2.1.1.1.17 |
||
|
OctetString
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.18 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.19 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.2 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.20 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.21 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.22 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.24 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.25 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.26 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.27 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.28 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.29 |
|
|
OctetString
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.3 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.30 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.31 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.32 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.33 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.34 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.35 |
|
|
OctetString
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.4 |
|
|
OctetString
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.5 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.6 |
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.7 |
||
.1.3.6.1.4.1.8886.1.18.2.1.1.1.8 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.1.1.1.9 |
|
.1.3.6.1.4.1.8886.1.18.2.2 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.10 |
|
|
Unsigned32
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.11 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.12 |
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.2 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.3 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.4 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.5 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.6 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.7 |
|
.1.3.6.1.4.1.8886.1.18.2.2.1.1.8 |
||
.1.3.6.1.4.1.8886.1.18.2.2.1.1.9 |
||
.1.3.6.1.4.1.8886.1.18.2.3 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1.1 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1.2 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1.3 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1.4 |
||
.1.3.6.1.4.1.8886.1.18.2.3.1.1.5 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2.1 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2.1.1 |
||
|
Integer32
|
.1.3.6.1.4.1.8886.1.18.2.3.2.1.2 |
|
.1.3.6.1.4.1.8886.1.18.2.3.2.1.3 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2.1.4 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2.1.5 |
||
.1.3.6.1.4.1.8886.1.18.2.3.2.1.6 |
||
.1.3.6.1.4.1.8886.1.18.2.4 |
||
.1.3.6.1.4.1.8886.1.18.2.4.1 |
||
.1.3.6.1.4.1.8886.1.18.2.4.1.1 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.1 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.10 |
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.11 |
||
|
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.12 |
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.13 |
||
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.2 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.3 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.4 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.5 |
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.6 |
||
|
Integer32
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.7 |
|
|
Integer32
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.8 |
|
|
Enumeration
|
.1.3.6.1.4.1.8886.1.18.2.4.1.1.9 |
|
.1.3.6.1.4.1.8886.1.18.3 |
||
.1.3.6.1.4.1.8886.1.18.4 |
Dependencies (10) 6 direct · 4 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- SNMPv2-CONFrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- RFC1155-SMIrfc
- RAISECOM-BASE-MIBraisecom
- SWITCH-TCraisecom
- RAISECOM-COMMON-MANAGEMENT-MIBraisecom
- RAISECOM-OPTICAL-TRANSCEIVER-MIBraisecomselected
Type Definitions (4)
| Enumeration |
enable(1)disable(2)enable or disable a function.
|
|
| Enumeration |
fifteenMin(1)twentyFourHour(2)This value indicates the time period over which performance
monitoring data has been collected. |
|
| Enumeration |
transceiverTemperature(1)txbiasCurrent(2)txPower(3)rxPower(4)laserTemperature(5)p5V0supplyVoltage(6)p3V3supplyVoltage(7)p1V8supplyVoltage(8)n5V2supplyVoltage(9)apdBiasVoltage(10)p5V0supplyCurrent(11)p3V3supplyCurrent(12)p1V8supplyCurrent(13)n5V2supplyCurrent(14)tecCurrent(15)laserWavelength(16)This value indicates the optical parameter that is
being monitored. Valid values are -OpticalParameterType transceiverTemperature(1) :transceiver temperature txbiasCurrent(2) :TX bias current txPower(3) :TX output power rxPower(4) :RX received optical power laserTemperature(5) :laser temperature p5V0supplyVoltage(6) :+5V supply voltage p3V3supplyVoltage(7) :+3.3V supply voltage p1V8supplyVoltage(8) :+1.8V supply voltage n5V2supplyVoltage(9) :-5.2V supply voltage apdBiasVoltage(10) :APD bias voltage p5V0supplyCurrent(11) :+5V supply currnet p3V3supplyCurrent(12) :+3.3V supply currnet p1V8supplyCurrent(13) :+1.8V supply currnet n5V2supplyCurrent(14) :-5.2V supply currnet tecCurrent(15) :TEC currnet laserWavelength(16) :laser wavelength |
|
| Integer32 |
range: -1000000range: -40000..6553600 The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical parameter being monitored, as identified by a corresponding object with syntax OpticalParameterType. When the optical parameter being monitored is 'XXTemperature',the supported range is from -40000 to 125000, in units of 1/1000 degrees centigrade. Example: A value of 23500 represents a temperature reading of 23.5 degrees C. The temperature is shown in unit of degrees centigrade, and the precision is 0.1. When the optical parameter being monitored is 'txbiasCurrent',the supported range is from 0 to 131000, in units of 1/1000 mA. Example: A value of 1000 represents a TX bias current reading of 1.0mA. The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'txPower',the supported range is from -40000 to 8200, in units of 1/1000 dbm. Example: A value of 77800 represents a TX output power reading of 7.78 dBm. The 'txPower' is shown in unit of dBm, and the precision is 0.1. When the optical parameter being monitored is 'rxPower',the supported range is from -40000 to 8200, in units of 1/1000 dbm. Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm. The 'rxPower' is shown in unit of dBm, and the precision is 0.1. When the optical parameter being monitored is 'XXsupplyVoltage',the supported range is from 0 to 6550, in units of 1/1000 V. Example: A value of 6000 represents a XX supply Voltage eading of 6.00V. The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01. When the optical parameter being monitored is 'apdBiasVoltage,the supported range is from 0 to 655300 , in units of 1/1000 V . Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V. The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1. When the optical parameter being monitored is 'XXsupplyCurrent',the supported range is from 0 to 6553600, in units of 1/1000 mA . Example: A value of 6000000 represents a XX supply current reading of 6000.0mA. The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'tecCurrent',the supported range is from 0 to 6553600, in units of 1/1000 mA . Example: A value of 6000000 represents a TEC Current reading of 6000.0mA. The 'tecCurrent' is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'laserWavelength,the supported range is from 0 to 3276750, in units of 1/1000 nm . Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm. The 'laserWavelength'is shown in unit of nm, and the precision is 0.01. |
Notifications / Traps (80)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.8886.1.18.3.1 |
This notification is sent when the optical module is removed from the device.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.10 |
This notification is sent when the optical module parameter value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.11 |
This notification is sent when the optical module parameter value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.12 |
This notification is sent when the optical module parameter value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.13 |
This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.14 |
This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.15 |
This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.16 |
This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.2 |
This notification is sent when the optical module is plugged into the device.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.3 |
This notification is sent when the transmitted or received data of optical module is invalid.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.4 |
This notification is sent when the transmitted or received data of optical module is valid.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.5 |
This notification is sent when the optical module receiving signal is lost.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.6 |
This notification is sent when the optical module receiving signal is back to normal.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.7 |
This notification is sent when the optical module password checking is failed.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.8 |
This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.3.9 |
This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.1 |
This notification is sent when the optical module Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.10 |
This notification is sent when the optical module Tx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.11 |
This notification is sent when the optical module Tx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.12 |
This notification is sent when the optical module Tx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.13 |
This notification is sent when the optical module Rx Power value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.14 |
This notification is sent when the optical module Rx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.15 |
This notification is sent when the optical module Rx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.16 |
This notification is sent when the optical module Rx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.17 |
This notification is sent when the optical module Laser Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.18 |
This notification is sent when the optical module Laser Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.19 |
This notification is sent when the optical module Laser Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.2 |
This notification is sent when the optical module Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.20 |
This notification is sent when the optical module Laser Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.21 |
This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.22 |
This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.23 |
This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.24 |
This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.25 |
This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.26 |
This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.27 |
This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.28 |
This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.29 |
This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.3 |
This notification is sent when the optical module Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.30 |
This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.31 |
This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.32 |
This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.33 |
This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.34 |
This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.35 |
This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.36 |
This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.37 |
This notification is sent when the optical module APD Bias Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.38 |
This notification is sent when the optical module APD Bias Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.39 |
This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.4 |
This notification is sent when the optical module Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.40 |
This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.41 |
This notification is sent when the optical module +5.0V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.42 |
This notification is sent when the optical module +5.0V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.43 |
This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.44 |
This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.45 |
This notification is sent when the optical module +3.3V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.46 |
This notification is sent when the optical module +3.3V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.47 |
This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.48 |
This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.49 |
This notification is sent when the optical module +1.8V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.5 |
This notification is sent when the optical module Tx bias Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.50 |
This notification is sent when the optical module +1.8V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.51 |
This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.52 |
This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.53 |
This notification is sent when the optical module -5.2V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.54 |
This notification is sent when the optical module -5.2V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.55 |
This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.56 |
This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.57 |
This notification is sent when the optical module TecCurrent value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.58 |
This notification is sent when the optical module TecCurrent value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.59 |
This notification is sent when the optical module TecCurrent value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.6 |
This notification is sent when the optical module Tx bias Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.60 |
This notification is sent when the optical module TecCurrent value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.61 |
This notification is sent when the optical module laserWavelength value increase to above
the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.62 |
This notification is sent when the optical module laserWavelength value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.63 |
This notification is sent when the optical module laserWavelength value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.64 |
This notification is sent when the optical module laserWavelength value dicrease to
under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.7 |
This notification is sent when the optical module Tx bias Current value increase to above
the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.8 |
This notification is sent when the optical module Tx bias Current value dicrease to
under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. |
|
.1.3.6.1.4.1.8886.1.18.4.9 |
This notification is sent when the optical module Tx Power value increase to above