RAISECOM-OPTICAL-TRANSCEIVER-MIB

Monitored by Observium
        This MIB module defines objects to monitor optical
characteristics on the optical interfaces in a network element. 
    
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
Source file
RAISECOM-OPTICAL-TRANSCEIVER-MIB
Last revised
Identity
raisecomOpticalTransceiver
Base OID
1.3.6.1.4.1.8886.1.18
Imported Objects
IF-MIB ifIndex
RAISECOM-BASE-MIB raisecomAgent
RAISECOM-COMMON-MANAGEMENT-MIB raisecomNotificationLocation
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC TEXTUAL-CONVENTION (no object page) TimeTicks
Net-SNMP examples using the raisecom MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAISECOM-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAISECOM-OPTICAL-TRANSCEIVER-MIB::raisecomOpticalTransceiver'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-OPTICAL-TRANSCEIVER-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-OPTICAL-TRANSCEIVER-MIB::raisecomOpticalTransceiver'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (92)
10 directly used by Observium
.1.3.6.1.4.1.8886.1.18
.1.3.6.1.4.1.8886.1.18.1
.1.3.6.1.4.1.8886.1.18.1.1
.1.3.6.1.4.1.8886.1.18.1.2
.1.3.6.1.4.1.8886.1.18.1.3
.1.3.6.1.4.1.8886.1.18.2
.1.3.6.1.4.1.8886.1.18.2.1
.1.3.6.1.4.1.8886.1.18.2.1.1
.1.3.6.1.4.1.8886.1.18.2.1.1.1
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.1
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.10
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.11
OctetString
.1.3.6.1.4.1.8886.1.18.2.1.1.1.12
.1.3.6.1.4.1.8886.1.18.2.1.1.1.13
.1.3.6.1.4.1.8886.1.18.2.1.1.1.14
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.15
.1.3.6.1.4.1.8886.1.18.2.1.1.1.16
.1.3.6.1.4.1.8886.1.18.2.1.1.1.17
OctetString
.1.3.6.1.4.1.8886.1.18.2.1.1.1.18
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.19
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.2
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.20
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.21
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.22
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.24
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.25
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.26
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.27
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.28
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.29
OctetString
.1.3.6.1.4.1.8886.1.18.2.1.1.1.3
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.30
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.31
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.32
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.33
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.34
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.35
OctetString
.1.3.6.1.4.1.8886.1.18.2.1.1.1.4
OctetString
.1.3.6.1.4.1.8886.1.18.2.1.1.1.5
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.6
.1.3.6.1.4.1.8886.1.18.2.1.1.1.7
.1.3.6.1.4.1.8886.1.18.2.1.1.1.8
Enumeration
.1.3.6.1.4.1.8886.1.18.2.1.1.1.9
.1.3.6.1.4.1.8886.1.18.2.2
.1.3.6.1.4.1.8886.1.18.2.2.1
.1.3.6.1.4.1.8886.1.18.2.2.1.1
.1.3.6.1.4.1.8886.1.18.2.2.1.1.1
Unsigned32
.1.3.6.1.4.1.8886.1.18.2.2.1.1.10
Unsigned32
.1.3.6.1.4.1.8886.1.18.2.2.1.1.11
Enumeration
.1.3.6.1.4.1.8886.1.18.2.2.1.1.12
.1.3.6.1.4.1.8886.1.18.2.2.1.1.2
.1.3.6.1.4.1.8886.1.18.2.2.1.1.3
.1.3.6.1.4.1.8886.1.18.2.2.1.1.4
.1.3.6.1.4.1.8886.1.18.2.2.1.1.5
.1.3.6.1.4.1.8886.1.18.2.2.1.1.6
Enumeration
.1.3.6.1.4.1.8886.1.18.2.2.1.1.7
.1.3.6.1.4.1.8886.1.18.2.2.1.1.8
.1.3.6.1.4.1.8886.1.18.2.2.1.1.9
.1.3.6.1.4.1.8886.1.18.2.3
.1.3.6.1.4.1.8886.1.18.2.3.1
.1.3.6.1.4.1.8886.1.18.2.3.1.1
.1.3.6.1.4.1.8886.1.18.2.3.1.1.1
.1.3.6.1.4.1.8886.1.18.2.3.1.1.2
.1.3.6.1.4.1.8886.1.18.2.3.1.1.3
.1.3.6.1.4.1.8886.1.18.2.3.1.1.4
.1.3.6.1.4.1.8886.1.18.2.3.1.1.5
.1.3.6.1.4.1.8886.1.18.2.3.2
.1.3.6.1.4.1.8886.1.18.2.3.2.1
.1.3.6.1.4.1.8886.1.18.2.3.2.1.1
Integer32
.1.3.6.1.4.1.8886.1.18.2.3.2.1.2
.1.3.6.1.4.1.8886.1.18.2.3.2.1.3
.1.3.6.1.4.1.8886.1.18.2.3.2.1.4
.1.3.6.1.4.1.8886.1.18.2.3.2.1.5
.1.3.6.1.4.1.8886.1.18.2.3.2.1.6
.1.3.6.1.4.1.8886.1.18.2.4
.1.3.6.1.4.1.8886.1.18.2.4.1
.1.3.6.1.4.1.8886.1.18.2.4.1.1
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.1
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.10
.1.3.6.1.4.1.8886.1.18.2.4.1.1.11
.1.3.6.1.4.1.8886.1.18.2.4.1.1.12
.1.3.6.1.4.1.8886.1.18.2.4.1.1.13
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.2
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.3
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.4
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.5
.1.3.6.1.4.1.8886.1.18.2.4.1.1.6
Integer32
.1.3.6.1.4.1.8886.1.18.2.4.1.1.7
Integer32
.1.3.6.1.4.1.8886.1.18.2.4.1.1.8
Enumeration
.1.3.6.1.4.1.8886.1.18.2.4.1.1.9
.1.3.6.1.4.1.8886.1.18.3
.1.3.6.1.4.1.8886.1.18.4
Dependencies (10) 6 direct · 4 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Type Definitions (4)
Enumeration
enable(1)
disable(2)
enable or disable a function.
Enumeration
fifteenMin(1)
twentyFourHour(2)
This value indicates the time period over which performance
monitoring data has been collected.
Enumeration
transceiverTemperature(1)
txbiasCurrent(2)
txPower(3)
rxPower(4)
laserTemperature(5)
p5V0supplyVoltage(6)
p3V3supplyVoltage(7)
p1V8supplyVoltage(8)
n5V2supplyVoltage(9)
apdBiasVoltage(10)
p5V0supplyCurrent(11)
p3V3supplyCurrent(12)
p1V8supplyCurrent(13)
n5V2supplyCurrent(14)
tecCurrent(15)
laserWavelength(16)
This value indicates the optical parameter that is
being monitored. Valid values are -OpticalParameterType

transceiverTemperature(1) :transceiver temperature
txbiasCurrent(2) :TX bias current
txPower(3) :TX output power
rxPower(4) :RX received optical power
laserTemperature(5) :laser temperature
p5V0supplyVoltage(6) :+5V supply voltage
p3V3supplyVoltage(7) :+3.3V supply voltage
p1V8supplyVoltage(8) :+1.8V supply voltage
n5V2supplyVoltage(9) :-5.2V supply voltage
apdBiasVoltage(10) :APD bias voltage
p5V0supplyCurrent(11) :+5V supply currnet
p3V3supplyCurrent(12) :+3.3V supply currnet
p1V8supplyCurrent(13) :+1.8V supply currnet
n5V2supplyCurrent(14) :-5.2V supply currnet
tecCurrent(15) :TEC currnet
laserWavelength(16) :laser wavelength
Integer32 range: -1000000range: -40000..6553600
The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical parameter being monitored,
as identified by a corresponding object with syntax OpticalParameterType.
When the optical parameter being monitored is 'XXTemperature',the supported range
is from -40000 to 125000, in units of 1/1000 degrees centigrade.
Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
The temperature is shown in unit of degrees centigrade, and the precision is 0.1.
When the optical parameter being monitored is 'txbiasCurrent',the supported range
is from 0 to 131000, in units of 1/1000 mA.
Example: A value of 1000 represents a TX bias current reading of 1.0mA.
The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'txPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
The 'txPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'rxPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm.
The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
is from 0 to 6550, in units of 1/1000 V.
Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
When the optical parameter being monitored is 'apdBiasVoltage,the supported range
is from 0 to 655300 , in units of 1/1000 V .
Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a XX supply current reading of 6000.0mA.
The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'tecCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'laserWavelength,the supported range
is from 0 to 3276750, in units of 1/1000 nm .
Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
Notifications / Traps (80)
NameOIDDescription
.1.3.6.1.4.1.8886.1.18.3.1
This notification is sent when the optical module is removed from the device.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.10
This notification is sent when the optical module parameter value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.11
This notification is sent when the optical module parameter value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.12
This notification is sent when the optical module parameter value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.13
This notification is sent when the optical module password cheching is successful.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.14
This notification is sent when the optical module password cheching is successful.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.15
This notification is sent when the optical module password cheching is successful.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.16
This notification is sent when the optical module password cheching is successful.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.2
This notification is sent when the optical module is plugged into the device.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.3
This notification is sent when the transmitted or received data of optical module is invalid.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.4
This notification is sent when the transmitted or received data of optical module is valid.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.5
This notification is sent when the optical module receiving signal is lost.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.6
This notification is sent when the optical module receiving signal is back to normal.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.7
This notification is sent when the optical module password checking is failed.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.8
This notification is sent when the optical module password cheching is successful.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.3.9
This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.


This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.1
This notification is sent when the optical module Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.10
This notification is sent when the optical module Tx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.11
This notification is sent when the optical module Tx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.12
This notification is sent when the optical module Tx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.13
This notification is sent when the optical module Rx Power value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.14
This notification is sent when the optical module Rx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.15
This notification is sent when the optical module Rx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.16
This notification is sent when the optical module Rx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.17
This notification is sent when the optical module Laser Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.18
This notification is sent when the optical module Laser Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.19
This notification is sent when the optical module Laser Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.2
This notification is sent when the optical module Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.20
This notification is sent when the optical module Laser Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.21
This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.22
This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.23
This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.24
This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.25
This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.26
This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.27
This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.28
This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.29
This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.3
This notification is sent when the optical module Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.30
This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.31
This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.32
This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.33
This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.34
This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.35
This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.36
This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.37
This notification is sent when the optical module APD Bias Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.38
This notification is sent when the optical module APD Bias Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.39
This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.4
This notification is sent when the optical module Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.40
This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.


This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.41
This notification is sent when the optical module +5.0V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.42
This notification is sent when the optical module +5.0V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.43
This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.44
This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.45
This notification is sent when the optical module +3.3V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.46
This notification is sent when the optical module +3.3V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.47
This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.48
This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.49
This notification is sent when the optical module +1.8V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.5
This notification is sent when the optical module Tx bias Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.50
This notification is sent when the optical module +1.8V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.51
This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.52
This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.53
This notification is sent when the optical module -5.2V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.54
This notification is sent when the optical module -5.2V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.55
This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.56
This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.57
This notification is sent when the optical module TecCurrent value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.58
This notification is sent when the optical module TecCurrent value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.59
This notification is sent when the optical module TecCurrent value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.6
This notification is sent when the optical module Tx bias Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.60
This notification is sent when the optical module TecCurrent value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.61
This notification is sent when the optical module laserWavelength value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.


This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.62
This notification is sent when the optical module laserWavelength value increase to above
the high warning threshold or dicrease to under the low warning threshold.


This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.63
This notification is sent when the optical module laserWavelength value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.64
This notification is sent when the optical module laserWavelength value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.7
This notification is sent when the optical module Tx bias Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.8
This notification is sent when the optical module Tx bias Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
.1.3.6.1.4.1.8886.1.18.4.9
This notification is sent when the optical module Tx Power value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.

This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.