PW-MPLS-STD-MIB
Monitored by Observium This MIB module complements the PW-STD-MIB module for PW
operation over MPLS.
Copyright (c) 2009 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the
following conditions are met:
- Redistributions of source code must retain the above
copyright notice, this list of conditions and the
following disclaimer.
- Redistributions in binary form must reproduce the above
copyright notice, this list of conditions and the following
disclaimer in the documentation and/or other materials
provided with the distribution.
- Neither the name of Internet Society, IETF or IETF Trust,
nor the names of specific contributors, may be used to
endorse or promote products derived from this software
without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS 'AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
This version of this MIB module is part of RFC 5602;
see the RFC itself for full legal notices.
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Pseudowires
Explore Observium network monitoring
- Source file
PW-MPLS-STD-MIB- Last revised
- Identity
pwMplsStdMIB- Base OID
1.3.6.1.2.1.181
Imported Objects
| IF-MIB | InterfaceIndexOrZero |
| MPLS-LSR-STD-MIB | MplsIndexType |
| MPLS-TC-STD-MIB | MplsLdpIdentifier MplsLsrIdentifier MplsTunnelIndex MplsTunnelInstanceIndex |
| PW-STD-MIB | pwIndex |
| PW-TC-STD-MIB | PwIndexType |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | mib-2 MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | StorageType |
Net-SNMP examples using the rfc MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'PW-MPLS-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PW-MPLS-STD-MIB::pwMplsStdMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PW-MPLS-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PW-MPLS-STD-MIB::pwMplsStdMIB'
Objects (41)
2 directly used by Observium
Showing 41 of 41 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.2.1.181 |
||
.1.3.6.1.2.1.181.0 |
||
.1.3.6.1.2.1.181.1 |
||
.1.3.6.1.2.1.181.1.1 |
||
.1.3.6.1.2.1.181.1.1.1 |
||
|
|
Bits
|
.1.3.6.1.2.1.181.1.1.1.1 |
|
Enumeration
|
.1.3.6.1.2.1.181.1.1.1.2 |
|
|
|
Unsigned32
|
.1.3.6.1.2.1.181.1.1.1.3 |
|
|
Unsigned32
|
.1.3.6.1.2.1.181.1.1.1.4 |
|
|
.1.3.6.1.2.1.181.1.1.1.5 |
|
|
Unsigned32
|
.1.3.6.1.2.1.181.1.1.1.6 |
|
|
|
.1.3.6.1.2.1.181.1.1.1.7 |
|
.1.3.6.1.2.1.181.1.1.1.8 |
||
.1.3.6.1.2.1.181.1.2 |
||
.1.3.6.1.2.1.181.1.2.1 |
||
.1.3.6.1.2.1.181.1.2.1.1 |
||
.1.3.6.1.2.1.181.1.2.1.2 |
||
.1.3.6.1.2.1.181.1.2.1.3 |
||
.1.3.6.1.2.1.181.1.2.1.4 |
||
.1.3.6.1.2.1.181.1.2.1.5 |
||
.1.3.6.1.2.1.181.1.2.1.6 |
||
|
Enumeration
|
.1.3.6.1.2.1.181.1.2.1.7 |
|
.1.3.6.1.2.1.181.1.3 |
||
.1.3.6.1.2.1.181.1.3.1 |
||
.1.3.6.1.2.1.181.1.3.1.1 |
||
.1.3.6.1.2.1.181.1.4 |
||
.1.3.6.1.2.1.181.1.4.1 |
||
|
Enumeration
|
.1.3.6.1.2.1.181.1.4.1.1 |
|
.1.3.6.1.2.1.181.1.4.1.2 |
||
.1.3.6.1.2.1.181.1.4.1.3 |
||
.1.3.6.1.2.1.181.1.4.1.4 |
||
.1.3.6.1.2.1.181.1.5 |
||
.1.3.6.1.2.1.181.1.5.1 |
||
.1.3.6.1.2.1.181.1.5.1.1 |
||
.1.3.6.1.2.1.181.1.5.1.2 |
||
.1.3.6.1.2.1.181.1.5.1.3 |
||
.1.3.6.1.2.1.181.1.5.1.4 |
||
.1.3.6.1.2.1.181.1.5.1.5 |
||
.1.3.6.1.2.1.181.2 |
||
.1.3.6.1.2.1.181.2.1 |
||
.1.3.6.1.2.1.181.2.2 |
Dependencies (16) 8 direct · 8 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
Conformance Groups (5)
|
pwMplsMplsType pwMplsExpBitsMode pwMplsExpBits pwMplsTtl pwMplsLocalLdpID pwMplsLocalLdpEntityIndex pwMplsPeerLdpID pwMplsStorageType
Collection of objects needed for PW over MPLS PSN
configuration. |
.1.3.6.1.2.1.181.2.1.1
|
|
|
Collection of objects needed for outbound association of
PW and MPLS tunnel. |
.1.3.6.1.2.1.181.2.1.2
|
|
|
pwMplsOutboundTunnelIndex pwMplsOutboundTunnelInstance pwMplsOutboundTunnelLclLSR pwMplsOutboundTunnelPeerLSR
Collection of objects needed for outbound association of
PW and MPLS-TE tunnel. |
.1.3.6.1.2.1.181.2.1.3
|
|
|
Collection of objects needed for inbound PW presentation.
This group MUST be supported if PW signaling through LDP is used. |
.1.3.6.1.2.1.181.2.1.4
|
|
|
Collection of objects needed for mapping association of
PW and MPLS tunnel. |
.1.3.6.1.2.1.181.2.1.5
|
Compliance Statements (2)
OID
.1.3.6.1.2.1.181.2.2.1The compliance statement for agents that provide full
support for the PW-MPLS-STD-MIB module. Such devices
can then be monitored and also be configured using
this MIB module.
support for the PW-MPLS-STD-MIB module. Such devices
can then be monitored and also be configured using
this MIB module.
Required groups
| mandatory | pwMplsGroup | |
| mandatory | pwMplsOutboundMainGroup | |
| mandatory | pwMplsInboundGroup | |
| mandatory | pwMplsMappingGroup | |
| optional | pwMplsOutboundTeGroup |
This group MUST be supported if the implementation allows MPLS-TE tunnels to carry PW traffic. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| pwMplsMplsType | Support of pwOnly(2) is not required. At least one of mplsTe(0) or mplsNonTe(1) MUST be supported if signaling of PW is supported. |
||
| pwMplsExpBitsMode | Support of specifiedValue(2) and serviceDependant(3) is optional. |
||
| pwMplsLocalLdpID | readonly | A read-write access is required if the implementation supports more than one LDP entity identifier for PW signaling. |
|
| pwMplsLocalLdpEntityIndex | readonly | A read-write access is required if the implementation supports more than one LDP entity index for PW signaling. |
|
| pwMplsOutboundLsrXcIndex | readonly | A value other than zero MUST be supported if the implementation supports non-TE signaling of the outer tunnel. A read-write access MUST be supported if the implementation supports PW label manual setting and carrying them over non-TE tunnels. |
|
| pwMplsOutboundIfIndex | readonly | A value other than zero and read-write operations MUST be supported if the implementation supports manually configured PW without MPLS outer tunnel. |
OID
.1.3.6.1.2.1.181.2.2.2The compliance statement for agents that provide read-
only support for the PW-MPLS-STD-MIB module. Such
devices can then be monitored but cannot be configured
using this MIB module.
only support for the PW-MPLS-STD-MIB module. Such
devices can then be monitored but cannot be configured
using this MIB module.
Required groups
| mandatory | pwMplsGroup | |
| mandatory | pwMplsOutboundMainGroup | |
| mandatory | pwMplsInboundGroup | |
| mandatory | pwMplsMappingGroup | |
| optional | pwMplsOutboundTeGroup |
This group MUST be supported if the implementation allows MPLS-TE tunnels to carry PW traffic. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| pwMplsMplsType | readonly | Write access is not required. Support of pwOnly(2) is not required. At least one of mplsTe(0) or mplsNonTe(1) MUST be supported if signaling of PW is supported. |
|
| pwMplsExpBitsMode | readonly | Write access is not required. Support of specifiedValue(2) and serviceDependant(3) is optional. |
|
| pwMplsExpBits | readonly | Write access is not required. | |
| pwMplsTtl | readonly | Write access is not required. | |
| pwMplsLocalLdpID | readonly | Write access is not required. | |
| pwMplsLocalLdpEntityIndex | readonly | Write access is not required. | |
| pwMplsStorageType | readonly | Write access is not required. | |
| pwMplsOutboundLsrXcIndex | readonly | Write access is not required. A value other than zero MUST be supported if the implementation supports non-TE signaling of the outer tunnel. |
|
| pwMplsOutboundTunnelIndex | readonly | Write access is not required. | |
| pwMplsOutboundTunnelLclLSR | readonly | Write access is not required. | |
| pwMplsOutboundTunnelPeerLSR | readonly | Write access is not required. | |
| pwMplsOutboundIfIndex | readonly | Write access is not required. A value other than zero MUST be supported if the implementation supports manually configured PW without MPLS outer tunnel. |