This management information module supports the objects to be used for redundancy of entities. |
entPhysicalIndex | ENTITY-MIB |
pdnEntityRedundancy | PDN-HEADER-MIB |
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP | SNMPv2-CONF |
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE | SNMPv2-SMI |
TEXTUAL-CONVENTION | SNMPv2-TC |
Name | Base Type | Values/Constraints |
---|---|---|
Bits | noAlarm(0), linkDefect(1), hwFailure(2), hwMissing(3), hwIncompatible(4), fwIncompatible(5), cfgIncompatible(6) | |
Enumeration | noCmd(1), switch(2), forcedswitch(3) | |
Bits | noAlarm(0), noActiveModule(1), standbyAlarmOrReset(2) | |
Enumeration | activeState(1), activeAlarmState(2), standbyState(3), standbyAlarmState(4) |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.2 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.3 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.4 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.4.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.4.1.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.5 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.5.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.5.1.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.5.1.2 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.5.1.3 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.1.6 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.2 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.2.0 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.3 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.3.1 | |
![]() | .1.3.6.1.4.1.1795.2.24.2.41.1.3.2 |
Name | OID | Description |
---|---|---|
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.1 | ication will be issued when no module is in the Active State. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.2 | ication will be issued when the modules in a redundancy configuration present hardware incompatibilities. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.3 | ication will be issued when one of the modules configured for redundancy is either in the Standby/Alarm or Reset Test state. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.4 | ication will be issued when the modules in a redundancy configuration present firmware incompatibilities. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.5 | ication will be issued when the modules in a redundancy configuration present configuration incompatibilities. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.6 | ication will be issued when a module in a redundancy configuration has a link condition. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.7 | ication will be issued when a module in a redundancy configuration has a hardware failure condition. | |
.1.3.6.1.4.1.1795.2.24.2.41.1.2.0.8 | ication will be issued when a module in a redundancy configuration is expecting a piece of hw to be used for redundancy which can not be found or is not operational. |