PDN-DS1EXT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
4
.1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1 · 1 row entry · 4 columns
The Paradyne DS1/G.703 extension configuration table.
This table is used for configuring extensions to DS1
and G.703 interfaces.
pdnDs1ExtConfEntry entry .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1
An entry in the Paradyne DS1/G.703 extension configuration table.
Note: The objects used depend on the type of interface.

For DS1: use pdnDs1ExtConfLineLengthType and one of
(pdnDs1ExtConfLineL…
Indexes
IF-MIBifIndex
Column Syntax OID
pdnDs1ExtConfLineLengthType
This entry specifies the type of loop length for the interface.
short-haul is intended for intra-building use.
long-haul is intended for inter-building use.
Enumerationr/w
Enumerated Values:
1shortHaul
2longHaul
.1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.1
pdnDs1ExtConfLineLength
This entry specifies the loop length, in feet, for a short-haul
DS1 line. This object only applies to DS1 interfaces.
Note: This object shares a mutually exclusive relationship
with the pdnDs1ExtConfLineBuildOut obje…
Enumerationr/w
Enumerated Values:
1feet000To133
2feet134To266
3feet267To399
4feet400To533
5feet534To655
.1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.2
pdnDs1ExtConfLineBuildOut
This entry specifies the line build out, in decibels, for a
long-haul DS1 line.
dB0Pnt0 = 0.0 dB
dB7Pnt5 = -7.5 dB
dB15Pnt0 = -15.0 dB
dB22Pnt5 = -22.5 dB
This object only applies t…
Enumerationr/w
Enumerated Values:
1dB0Pnt0
2dB7Pnt5
3dB15Pnt0
4dB22Pnt5
.1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.3
pdnDs1ExtConfConnector
This entry specifies the type of connector to be used.
This object only applies to G.703 interfaces.

bnc: 75-Ohm connector supporting only short-haul.
rj48: 120-Ohm connector supporting both short-haul an…
Enumerationr/w
Enumerated Values:
1bnc
2rj48
.1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.4