NORTEL-OME6500-EQPT-MIB
Optical Multiservice Edge (ome)
This Module will be used to identify the equipment attributes for
the Nortel OME6500 40G cards.
nnOme6500Equipments
1.3.6.1.4.1.562.68.11.2
Imported Objects
| ENTITY-MIB | entPhysicalIndex |
| NORTEL-OPTICAL-OME6500-MIB | ome6500 |
| RFC1213-MIB | DisplayString |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | RowStatus |
Type Definitions (6)
| AdminState | Enumeration |
unknown(0)is(1)oos(2) |
| Boolean | Enumeration |
false(0)true(1) |
| EquipmentMode | Enumeration |
unknown(0)nil(1)internal(2)mated(3)xconnect(4)internal-mated(5)internal-xconnect(6)mated-xconnect(7)internal-mated-xconnect(8)matedsym(9)internal-matedsym(10)matedsym-xc(11)internal-matedsym-xconnect(12)mate-pending(13)mate-pending-xconnect(14) |
| EquipmentType | Enumeration |
eNil(0)eEMPTY(1)eUNKNOWN(2)eILAN(3)eODU2(4)eDS1(5)eDS3(6)eOC3(7)eXC(8)eSP(9)eFC100(10)eOC12(11)eSTS1DS3(12)eSTS1E3(13)eVT1DS1(14)eVT2E1(15)eSMUX(16)eFC200(17)eEC1(18)eE1WAN(19)eFC400(20)eVCE-ETH10G(21)eVCEMAP-ETH10G(22)e40GMUX(23)e20GL2SS(24)eDS1WAN(25)eEIO(26)eE3WAN(27)e40GOCI(28)e40GOCLD(29)eDS3V(30)eDS3WAN(31)eE1(32)eP10GSOELFC(33)eOTS(34)eWSSOPM(35)e155ME(36)e155MEP(37)eOC48(38)ePWR(39)eFILLED-IO(40)eBNC-IO(41)eFAN(42)eE1DS3(43)eE1E3(44)eVT2DS3(45)eVT2E3(46)ePGE(47)ePGEFC200(48)eDS1TM(49)eDSMBP(50)eDSMOAMEX(51)eDSMFANX3(52)eDSMIO(53)eDSM(54)eCMD44(55)eDINPIO(56)eBackplane(57)e1GFOSFC(58)eFILLED(59)eFC1200(60)eOC192(61)eSLOT(62)eMIC(63)eAP(64)eFILLER(65)eFANHOUSING(66)e155622M(67)e2G5(68)e10G(69)e1GFOS(70)eP155622M(71)eP2G5(72)eP2G5W(73)ePGEFC(74)eETH(75)eFC(76)eWAN(77)eSTS1(78)eSTS3c(79)eSTS12c(80)eSTS24c(81)eSTS48c(82)eSTS192c(83)eVT15(84)eVT2(85)eVT6(86)e2G5W(87)e10GW(88)eBITSIN(89)eBITSOUT(90)eDS3EC1(91)eE1PSM-IO(92)eE1CNV-IO(93)eGMD(94)eDOSC(95)eCMD4(96)eLIM(97)eSLA(98)eMLA(99)eVOA(100)eEDFA(101)eOPTMON(102)eOSC(103)eDOC(104)eP155M(105)eP622M(106)eADJ(107)eDS3EC1P(108)eE1P(109)eCOLAN(110)eWAYSIDE(111)eADJTX(112)eADJRX(113)eADJLN(114)eNC(115)eVT15AU4(116)eVT2AU4(117)eVT6AU4(118)eSTS1AU4(119)eDSCM(120)eSHELF(121)eSWT(122)eOST(123)eOPM(124)eWB(125)e10GOCWT(126)e10GELWT(127)eOC768(128)e2G5MX(129)eOTM1(130)eOTM2(131)eOTM3(132)eETH10G(133)ePUNKNOWN(134)eP155Me(135)eSTM1e(136)eL2SS(137)eLAN(138)eENV(139)eCONT(140)e1FN-BNC-IO(141)eDEST(142)eUOSC(143)eCMD8(144)eWSS(145)eCHC(146)eSCO(147)eVCS(148)eVCE(149)eVCE-ETH(150)eVCE-WAN(151)eVCE-LAG(152)eVCEMAP(153)eVCEMAP-ETH(154)eVCEMAP-WAN(155)eVCEMAP-LAG(156)eBWPRF(157)eDMPRF(158)eCFPRF(159)eFE(160)ePFE(161)eP10GS(162)eP10GEL(163)eP10GSEL(164)eP10GSOEL(165)e10GOCLD(166)e2xOSC(167)e10GOTR(168)eTMUX(169)eDS1DS3(170)eVT1DS3(171)eSE(172)eRPR(173)eMXC(174)eCOSST(175)eCOSBR(176)eCOSSL(177)eCOSGD(178)eCOSPL(179)eCOSPR(180)eCOSNT(181)eCOSCR(182)eLAG(183)eETH100(184)eCHMON(185)eE1MIO75P(186)eE1MIO120P(187)eE1MIO75U(188)eE1MIO120U(189)eTNS(190)eTNE(191)eTNE-ETH(192)eTNE-WAN(193)eTNE-RPR(194)eTNE-LAG(195)eTNEMAP(196)eTNEMAP-ETH(197)eTNEMAP-WAN(198)eTNEMAP-RPR(199)eTNEMAP-LAG(200)eVCE-RPR(201)eVCEMAP-RPR(202)eRPR-RING(203)eRPR-RINGLET(204)eCOS(205)eRPR-STATION(206)e10GOTNWT(207)eLNGRP(208)eWTGRP(209)eFE-IO(210)eOCH(211)ePRTSCHED(212)eHOP(213)eE3(214)e10GOTSC(215)eFDB(216)eFDBSTATIC(217)eCOSA(218)eCOSBC(219)eCOSBE(220)eCOSC(221)eXGE(222)eDRA(223)eRAMAN(224)eVCEA(225)eVCEBC(226)eVCEBE(227)eVCEC(228)eTNEA(229)eTNEBC(230)eTNEBE(231)eTNEC(232)ePCWDMS(233)eSCHPRF(234)eVCEST(235)eVCESL(236)eVCEGD(237)eVCEPR(238)eVCENT(239)eTNEST(240)eTNESL(241)eTNEGD(242)eTNEPR(243)eTNENT(244)ePFC400(245)eDISP(246)eHEXOCN(247)eODU3(248)eCMDA(249)e10GWT(250)e2G5MOTR(251)eGENERIC(252)eDS3E3EC1(253)eDS3E3EC1P(254)eGE(255)eL2RPR(256)eMRO(257)eOTSC(258)eMRO2(259)eL2MOTR(260)eTPT(261)eOMX(262)e40GXCIF(263)e100GOCLD(264)e100GOCI(265)e100GMUX(266)e40GUMUX(267)e40GUOCLD(268)eOSIC(269)eFLEXMOTR(270)ePCFP(271)ePSFP(272)eOTNFMOTR(273)eSPOTNFMOTR(274)eCCMD12(275)eSMD(276)eOTNFLEX(277)eOTNXCIF(278)eSLIC(279)ePPC6(280)eBS(281)eOMDF4(282)eOMDF8(283)eOSCF(284)eFGA(285)ePXFP(286)eOPS(287)eEVOA(288)eEMOTR(289)ePKTFLEX(290)eSRA(291)eSAM(292)eESAM(293)eXLA(294)eISS(295)ePQSFP(296)eOTR(297)ePKTOTN(298)ePKTOTNXCIF(299)eCCMD8X16(300)ePCXM(301)eFIM(302)eBMD(303)eGMD10(304)eMOTR(305)eMAX(306) |
| PrimaryState | Enumeration |
unknown(0)is(1)is-anr(2)oos-au(3)oos-ma(4)oos-auma(5)oos-maanr(6) |
| SecondaryState | Enumeration |
unknown(0)nil(1)act(2)idle(3)sgeo(4)psi(5)flt(6)mea(7)stbyh(8)ts(9)ueq(10)wrk(11)wrksync(12)wrktraf(13)faf(14)meaAndFlt(15)actAndFlt(16)actAndWrksync(17)actAndFltAndWrksync(18)idleAndFlt(19)idleAndWrksync(20)idleAndFltAndWrksync(21)wrktrafAndWrksync(22)ains(23)actAndAins(24)ainsAndIdle(25)ainsAndSgeo(26)ainsAndPsi(27)ainsAndFlt(28)ainsAndMea(29)ainsAndStbyh(30)ainsAndTs(31)ainsAndUeq(32)ainsAndWrk(33)ainsAndWrksync(34)ainsAndWrktraf(35)ainsAndFaf(36)ainsAndMeaAndFlt(37)actAndAinsAndFlt(38)actAndAinsAndWrksync(39)actAndAinsAndFltAndWrksync(40)ainsAndIdleAndFlt(41)ainsAndIdleAndWrksync(42)ainsAndIdleAndFltAndWrksync(43)ainsAndWrktrafAndWrksync(44)idleAndUeq(45)fltAndWrksync(46)wrkctrl(47)actAndWrkctrl(48)idleAndWrkctrl(49)ainsAndWrkctrl(50)fltAndWrkctrl(51)actAndFltAndWrkctrl(52)idleAndFltAndWrkctrl(53)actAndAinsAndWrkctrl(54)actAndAinsAndFltAndWrkctrl(55)ainsAndIdleAndWrkctrl(56)ainsAndIdleAndFltAndWrkctrl(57)wrktrafAndWrksyncAndWrkctrl(58)ainsAndWrktrafAndWrksyncAndWrkctrl(59)ueqAndStbyh(60)ainsAndUeqAndStbyh(61)meaAndStbyh(62)fltAndStbyh(63)fltAndWrktrafAndWrksync(64)meaAndWrksync(65)ueqAndWrksync(66)actAndWrk(67)idleAndWrk(68)actAndStbyh(69)idleAndStbyh(70)stbys(71)ainsAndStbys(72)ueqAndStbys(73)ainsAndUeqAndStbys(74)meaAndStbys(75)fltAndStbys(76)actAndStbys(77)idleAndStbys(78)fltAndWrk(79)fltAndUeq(80)fltAndWrktraf(81)fltAndWrktrafAndWrksyncAndWrkctrl(82)fltAndSgeo(83)idleAndSgeo(84)idleAndWrkAndUeq(85)idleAndStbysAndUeq(86)idleAndStbysAndFlt(87)idleAndStbyhAndUeq(88)idleAndStbyhAndFlt(89)wrktrafAndWrkctrl(90)wrksyncAndWrkctrl(91)actAndUeq(92)wrkAndMea(93)idleAndMea(94) |
Objects (36)
|
|
.1.3.6.1.4.1.562.68.11.2 |
|
|
|
.1.3.6.1.4.1.562.68.11.2.1 |
|
|
|
.1.3.6.1.4.1.562.68.11.2.1.1 |
|
|
|
ENTITY-MIBentPhysicalIndex | .1.3.6.1.4.1.562.68.11.2.1.1.1 |
|
|
EquipmentType | .1.3.6.1.4.1.562.68.11.2.1.1.1.1 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.10 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.11 |
|
|
SNMPv2-TCRowStatus | .1.3.6.1.4.1.562.68.11.2.1.1.1.12 |
|
|
Enumeration | .1.3.6.1.4.1.562.68.11.2.1.1.1.13 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.14 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.1.1.1.15 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.2 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.3 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.1.1.1.4 |
|
|
AdminState | .1.3.6.1.4.1.562.68.11.2.1.1.1.5 |
|
|
PrimaryState | .1.3.6.1.4.1.562.68.11.2.1.1.1.6 |
|
|
SecondaryState | .1.3.6.1.4.1.562.68.11.2.1.1.1.7 |
|
|
EquipmentMode | .1.3.6.1.4.1.562.68.11.2.1.1.1.8 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.1.1.1.9 |
|
|
.1.3.6.1.4.1.562.68.11.2.2 |
|
|
|
.1.3.6.1.4.1.562.68.11.2.2.1 |
|
|
|
ENTITY-MIBentPhysicalIndex | .1.3.6.1.4.1.562.68.11.2.2.1.1 |
|
|
EquipmentType | .1.3.6.1.4.1.562.68.11.2.2.1.1.1 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.10 |
|
|
Boolean | .1.3.6.1.4.1.562.68.11.2.2.1.1.11 |
|
|
Enumeration | .1.3.6.1.4.1.562.68.11.2.2.1.1.12 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.2.1.1.13 |
|
|
Enumeration | .1.3.6.1.4.1.562.68.11.2.2.1.1.14 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.2 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.3 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.2.1.1.4 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.5 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.2.1.1.6 |
|
|
OctetString | .1.3.6.1.4.1.562.68.11.2.2.1.1.7 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.8 |
|
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.2.2.1.1.9 |