NMS-EPON-OLT-PON Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
48

nmseponoltponTable

table mandatory
.1.3.6.1.4.1.3320.101.6.1 · 1 row entry · 23 columns
Uses the bdcom variant from /opt/observium/mibs/bdcom.
Command help
Walk nmseponoltponTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NMS-EPON-OLT-PON' -M '/opt/observium/mibs/bdcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NMS-EPON-OLT-PON::nmseponoltponTable'
A list of epon olt pon property table entries.
nmsEponOltPonEntry row .1.3.6.1.4.1.3320.101.6.1.1
A collection of additional objects in the
epon olt pon property table.
Indexes
Column Syntax OID
ponIfIndexmandatory
The only diid of PON port in System.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.1
Currnet LLID seqence number.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.2
onuAuthMethodmandatory
ONU authentication method.
Enumerationr/w
Enumerated Values:
0none
1manual
3mac
4loid
6hybrid
.1.3.6.1.4.1.3320.101.6.1.1.3
isCheckOnuMacmandatory
Check ONU MAC when registering.
Enumeration
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.3320.101.6.1.1.4
Check if PON belongs to PSG.
Enumeration
Enumerated Values:
0alone_pon
1b-psg
2active_pon
3standby_pon
4c-psg
.1.3.6.1.4.1.3320.101.6.1.1.5
PSG ID that PON belongs to.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.6
If using MPCP registe Ack delay time.
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.3320.101.6.1.1.7
MPCP registe Ack delay time,range is 1-50ms.
Integer32r/w
Constraints:
range: 1-50
.1.3.6.1.4.1.3320.101.6.1.1.8
PON interface Administration Status.
Enumerationr/w
Enumerated Values:
1up
2down
.1.3.6.1.4.1.3320.101.6.1.1.9
PON interface in FEC Status.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.10
PON interface out FEC Status.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.11
PON interface Laser Status.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.12
PON interface data exchange Status with ONU.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.13
PON interface protected Status.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.14
PON interface dynamic MAC address learning Status.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.3320.101.6.1.1.15
ponIfMacACLmandatory
PON interface MAC address ACL.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.3320.101.6.1.1.16
ponIfIpACLmandatory
PON interface IP address ACL.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.3320.101.6.1.1.17
Fiber protect hand in hand. 1-enable,2-disable. Default is disable.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.18
Fiber protect group. The range of groupID is 0-32. 0 means disable. Default is disable.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.19
Fiber splits ratio, for each OLT PON port, which means the max number of ONU.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.20
activeOnuNummandatory
Currnet active ONU number.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.21
Currnet inactive ONU number.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.1.1.22
Llid ports ifindex string. Seperated with comma.
OctetString .1.3.6.1.4.1.3320.101.6.1.1.23
.1.3.6.1.4.1.3320.101.6.2 · 1 row entry · 25 columns
Uses the bdcom variant from /opt/observium/mibs/bdcom.
Command help
Walk ponOpticsParameterAlarmSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NMS-EPON-OLT-PON' -M '/opt/observium/mibs/bdcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NMS-EPON-OLT-PON::ponOpticsParameterAlarmSetTable'
A list of epon olt pon optics Parameter Alarm set table entries.
ponOpticsParameterAlarmSetEntry row .1.3.6.1.4.1.3320.101.6.2.1
A collection of additional objects in the epon olt pon optics Parameter Alarm set table.
Indexes
Column Syntax OID
ifIndexmandatory
The only diid of PON port in System.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.6.2.1.1
Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.2
The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
Integer32r/w
Constraints:
range: -400-82
.1.3.6.1.4.1.3320.101.6.2.1.3
The upper threshold of tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82.
Integer32r/w
Constraints:
range: -400-82
.1.3.6.1.4.1.3320.101.6.2.1.4
Enable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.5
The low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.
Integer32r/w
Constraints:
range: -400-82
.1.3.6.1.4.1.3320.101.6.2.1.6
The low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.
Integer32r/w
Constraints:
range: -400-82
.1.3.6.1.4.1.3320.101.6.2.1.7
Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.8
The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.6.2.1.9
The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.6.2.1.10
Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.11
The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.6.2.1.12
The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.6.2.1.13
Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.14
The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.6.2.1.15
The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.6.2.1.16
Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.17
The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.6.2.1.18
The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.6.2.1.19
Enable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.20
The upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310.
Integer32r/w
Constraints:
range: 0-1310
.1.3.6.1.4.1.3320.101.6.2.1.21
The upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310.
Integer32r/w
Constraints:
range: 0-1310
.1.3.6.1.4.1.3320.101.6.2.1.22
Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.6.2.1.23
The low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0.
Integer32r/w
Constraints:
range: 0-1310
.1.3.6.1.4.1.3320.101.6.2.1.24
The low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0.
Integer32r/w
Constraints:
range: 0-1310
.1.3.6.1.4.1.3320.101.6.2.1.25