NEXT-UPS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
41
upsInTable
table.0.1.1.4.5
·
1 row entry
·
8 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk upsInTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::upsInTable'
A list of input table entries. The number of entries is given by the value of upsInputNumLines.
An entry containing information applicable to a
particular input line.
particular input line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The number of output lines
|
Integer32 Constraints: range: 0-10 |
.0.1.1.4.5.1.1 |
|
The present input frequency.
|
0.1 HertzUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.4.5.1.2 |
|
The input utility line voltage .
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.4.5.1.3 |
|
The magnitude of the present input current
|
0.1AmpInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.4.5.1.4 |
|
The magnitude of the present input Apparent power.
|
0.1VAUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.4.5.1.5 |
|
The magnitude of the present input true power.
|
0.1WattsUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.4.5.1.6 |
|
Input true power/apparent power factor
|
0.01UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.4.5.1.7 |
|
The input utility line voltage .
if upsInLineIndex =1, upsInLineVoltage = Line voltage of RS phase; if upsInLineIndex =2, upsInLineVoltage = Line voltage of ST phase; if upsInLineIndex =3, upsInLineVoltage = Line voltag… |
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.4.5.1.8 |
upsOutTable
table.0.1.1.5.7
·
1 row entry
·
9 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk upsOutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::upsOutTable'
A list of output table entries. The number of entries is given by the value of upsOutputNumLines.
An entry containing information applicable to a
particular output line.
particular output line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The output line identifier.
|
Integer32 Constraints: range: 0-10 |
.0.1.1.5.7.1.1 |
|
The output voltage of the UPS system.
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.5.7.1.2 |
|
The output current of the UPS system
|
0.1 AmpInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.5.7.1.3 |
|
The present output apparent power.
|
0.1VAUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.5.7.1.4 |
|
The present output true power.
|
0.1WattsUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.5.7.1.5 |
|
Output true power/apparent power factor
|
0.01UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.5.7.1.6 |
|
The percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA. |
percentInteger32 Constraints: range: 0-100 |
.0.1.1.5.7.1.7 |
|
The output line voltage of the UPS system.
if upsOutLineIndex =1, upsOutLineVoltage = Line voltage of RS phase; if upsOutLineIndex =2, upsOutLineVoltage = Line voltage of ST phase; if upsOutLineIndex =3, upsOutLineVol… |
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.5.7.1.8 |
|
The present output frequency.
|
0.1HertzUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.5.7.1.9 |
upsByTable
table.0.1.1.6.3
·
1 row entry
·
5 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk upsByTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::upsByTable'
A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.
An entry containing information applicable to a
particular bypass input.
particular bypass input.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The bypass line identifier.
|
Integer32 Constraints: range: 0-65535 |
.0.1.1.6.3.1.1 |
|
The present bypass voltage.
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.6.3.1.2 |
|
The present bypass current.
|
0.1 RMS AmpInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.6.3.1.3 |
|
The present true power conveyed by the bypass.
|
0.1WattsUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.1.6.3.1.4 |
|
The present bypass line voltage.
if upsByLineIndex=1,upsByLineVoltage=Line voltage of RS phase; if upsByLineIndex=2,upsByLineVoltage=Line voltage of ST phase; if upsByLineIndex=3,upsByLineVoltage=Line voltage of TR phas… |
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.1.6.3.1.5 |
solarGridTable
table.0.1.2.4.8
·
1 row entry
·
4 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk solarGridTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::solarGridTable'
A list of solar grid table entries. The number of entries is given by the value of solarGridputNumLines.
An entry containing information applicable to a
particular grid line.
particular grid line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The grid line identifier.
|
Integer32 Constraints: range: 0-10 |
.0.1.2.4.8.1.1 |
|
The Grid voltage of the solar inverter
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.4.8.1.2 |
|
The Grid current of the solar inverter
|
0.1 AmpInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.4.8.1.3 |
|
The present Grid output true power.
|
0.1WattsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.4.8.1.4 |
solarACOutTable
table.0.1.2.5.5
·
1 row entry
·
5 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk solarACOutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::solarACOutTable'
A list of AC output table entries. The number of entries is given by the value of solarACOut NumLines.
An entry containing information applicable to a
particular input line.
particular input line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The number of PV line identifier.
|
Integer32 Constraints: range: 0-10 |
.0.1.2.5.5.1.1 |
|
The AC output voltage .
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.5.5.1.2 |
|
The magnitude of the present AC output true power.
|
0.1WattsUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.2.5.5.1.3 |
|
The magnitude of the present AC output current.
|
0.1AInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.5.5.1.4 |
|
The magnitude of the present AC output percent load
|
percentInteger32 Constraints: range: 0-100 |
.0.1.2.5.5.1.5 |
solarPVTable
table.0.1.2.6.3
·
1 row entry
·
3 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk solarPVTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::solarPVTable'
A list of solar PV input table entries. The number of entries is given by the value of solarPV NumLines.
An entry containing information applicable to a
particular input line.
particular input line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The number of PV line identifier.
|
Integer32 Constraints: range: 0-10 |
.0.1.2.6.3.1.1 |
|
The PV input voltage .
|
0.1 VoltsInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.6.3.1.2 |
|
The magnitude of the present input true power.
|
0.1WattsUPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.0.1.2.6.3.1.3 |
solarFaultTable
table.0.1.2.10.19
·
1 row entry
·
7 columns
Uses the nextupssystems variant from
Command help
/opt/observium/mibs/nextupssystems.
Walk solarFaultTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEXT-UPS-MIB' -M '/opt/observium/mibs/nextupssystems:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEXT-UPS-MIB::solarFaultTable'
A list of fault table entries. The number of entries is given by the value of solarFault NumLines.
An entry containing information applicable to a
particular input line.
particular input line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The number of inverter,grid and ACOutput line identifier.
|
Integer32 Constraints: range: 0-10 |
.0.1.2.10.19.1.1 |
|
Inverter voltage before fault.
|
0.1VoltInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.2 |
|
Inverter current before fault.
|
0.1AInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.3 |
|
Grid voltage before fault.
|
0.1VoltInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.4 |
|
Grid current before fault.
|
0.1AInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.5 |
|
AC output voltage before fault.
|
0.1VoltInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.6 |
|
AC output current before fault.
|
0.1AInteger32 Type Constraints: range: -2147483648..2147483647 |
.0.1.2.10.19.1.7 |