NEWTEC-ANTENNA-CONTROLLER-MIB

Newtec modular DVB modulator MIB containing definitions for the OpenAMIP controller.

Source file
NEWTEC-ANTENNA-CONTROLLER-MIB
Last revised
Identity
ntcAntennaController
Base OID
1.3.6.1.4.1.5835.5.2.5700
Objects
2 scalars · 23 columns
Tables
3 tables
Net-SNMP examples using the newtec MIB directory

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'NEWTEC-ANTENNA-CONTROLLER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NEWTEC-ANTENNA-CONTROLLER-MIB::ntcAntennaController'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEWTEC-ANTENNA-CONTROLLER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEWTEC-ANTENNA-CONTROLLER-MIB::ntcAntennaController'
Command help
Imported Objects
FLOAT-TC-MIB Float32TC
NEWTEC-MAIN-MIB ntcFunction
NEWTEC-TC-MIB NtcAlarmState NtcEnable
SNMPv2-CONF MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI IpAddress MODULE-IDENTITY (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32
.1.3.6.1.4.1.5835.5.2.5700.1.1.1 · 12 columns
OID Tree

A table containing the ntcAntCtrlCfg

ntcAntCtrlCfgEntry .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1
Column Syntax OID
ntcAntCtrlCfgControlIdEnumeration.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.1
ntcAntCtrlCfgEnableNEWTEC-TC-MIBNtcEnabler/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.2
ntcAntCtrlCfgIpAddressSNMPv2-SMIIpAddressr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.3
ntcAntCtrlCfgPortUnsigned32r/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.4
ntcAntCtrlCfgSatLongdeg.FLOAT-TC-MIBFloat32TCr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.5
ntcAntCtrlCfgSatLatVardeg.FLOAT-TC-MIBFloat32TCr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.6
ntcAntCtrlCfgSatSkewdeg.FLOAT-TC-MIBFloat32TC.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.7
ntcAntCtrlCfgRxPolEnumerationr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.8
ntcAntCtrlCfgTxPolEnumerationr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.9
ntcAntCtrlCfgRxLoFreqkHzUnsigned32r/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.10
ntcAntCtrlCfgTxLoFreqkHzUnsigned32r/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.11
ntcAntCtrlCfgTxMaxSkewdeg.FLOAT-TC-MIBFloat32TCr/w.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.12
.1.3.6.1.4.1.5835.5.2.5700.1.2.1 · 8 columns
OID Tree
Monitoring table
ntcAntCtrlMonEntry .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1
Column Syntax OID
ntcAntCtrlMonControlIdEnumeration.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.1
ntcAntCtrlIntervalsUnsigned32.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.2
ntcAntCtrlAntStatusEnumeration.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.3
ntcAntCtrlTxAllowedEnumeration.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.4
ntcAntCtrlLatitudedeg.FLOAT-TC-MIBFloat32TC.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.5
ntcAntCtrlLongitudedeg.FLOAT-TC-MIBFloat32TC.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.6
ntcAntCtrlTxMsgSNMPv2-SMIUnsigned32.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.7
ntcAntCtrlRxMsgSNMPv2-SMIUnsigned32.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.8
.1.3.6.1.4.1.5835.5.2.5700.1.3.1 · 3 columns
OID Tree
Alarm Status table
ntcAntCtrlAlarmStatsEntry .1.3.6.1.4.1.5835.5.2.5700.1.3.1.1
Column Syntax OID
ntcAntCtrlAlarmStatsControlIdEnumeration.1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.1
ntcAntCtrlCommErrorStatNEWTEC-TC-MIBNtcAlarmState.1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.2
ntcAntCtrlAntFailureStatNEWTEC-TC-MIBNtcAlarmState.1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.3

ScalarsntcAntCtrlAlarm

ntcAntCtrlObjects · .1.3.6.1.4.1.5835.5.2.5700.1.3
Object Syntax OID
ntcAntCtrlCommErrorNEWTEC-TC-MIBNtcAlarmState.1.3.6.1.4.1.5835.5.2.5700.1.3.2
ntcAntCtrlAntFailureNEWTEC-TC-MIBNtcAlarmState.1.3.6.1.4.1.5835.5.2.5700.1.3.3

Conformance Groups (1)

ntcAntCtrlConfGrpV1Standard .1.3.6.1.4.1.5835.5.2.5700.2.2.1 Members (22)

Compliance Statements (1)

ntcAntCtrlConfCompV1Standard .1.3.6.1.4.1.5835.5.2.5700.2.1.1
Dependencies (6) 5 direct · 1 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-TCrfc
  3. FLOAT-TC-MIBrfc
  4. NEWTEC-MAIN-MIBnewtec
  5. NEWTEC-TC-MIBnewtec
  6. SNMPv2-CONFrfc
  7. NEWTEC-ANTENNA-CONTROLLER-MIBnewtecselected