NEWTEC-ANTENNA-CONTROLLER-MIB
Newtec modular DVB modulator MIB containing definitions for the OpenAMIP controller.
- Source file
NEWTEC-ANTENNA-CONTROLLER-MIB- Last revised
- Identity
ntcAntennaController- Base OID
1.3.6.1.4.1.5835.5.2.5700- Objects
- 2 scalars · 23 columns
- Tables
- 3 tables
Net-SNMP examples using the newtec MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'NEWTEC-ANTENNA-CONTROLLER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NEWTEC-ANTENNA-CONTROLLER-MIB::ntcAntennaController'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEWTEC-ANTENNA-CONTROLLER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEWTEC-ANTENNA-CONTROLLER-MIB::ntcAntennaController'
Imported Objects
| FLOAT-TC-MIB | Float32TC |
| NEWTEC-MAIN-MIB | ntcFunction |
| NEWTEC-TC-MIB | NtcAlarmState NtcEnable |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | IpAddress MODULE-IDENTITY (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32 |
.1.3.6.1.4.1.5835.5.2.5700.1.1.1
· 12 columns
A table containing the ntcAntCtrlCfg
ntcAntCtrlCfgEntry
.1.3.6.1.4.1.5835.5.2.5700.1.1.1.1
Index
ntcAntCtrlCfgControlId
| Column | Syntax | OID |
|---|---|---|
| ntcAntCtrlCfgControlId | Enumeration | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.1 |
| ntcAntCtrlCfgEnable | NEWTEC-TC-MIBNtcEnabler/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.2 |
| ntcAntCtrlCfgIpAddress | SNMPv2-SMIIpAddressr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.3 |
| ntcAntCtrlCfgPort | Unsigned32r/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.4 |
| ntcAntCtrlCfgSatLong | deg.FLOAT-TC-MIBFloat32TCr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.5 |
| ntcAntCtrlCfgSatLatVar | deg.FLOAT-TC-MIBFloat32TCr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.6 |
| ntcAntCtrlCfgSatSkew | deg.FLOAT-TC-MIBFloat32TC | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.7 |
| ntcAntCtrlCfgRxPol | Enumerationr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.8 |
| ntcAntCtrlCfgTxPol | Enumerationr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.9 |
| ntcAntCtrlCfgRxLoFreq | kHzUnsigned32r/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.10 |
| ntcAntCtrlCfgTxLoFreq | kHzUnsigned32r/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.11 |
| ntcAntCtrlCfgTxMaxSkew | deg.FLOAT-TC-MIBFloat32TCr/w | .1.3.6.1.4.1.5835.5.2.5700.1.1.1.1.12 |
.1.3.6.1.4.1.5835.5.2.5700.1.2.1
· 8 columns
Monitoring table
ntcAntCtrlMonEntry
.1.3.6.1.4.1.5835.5.2.5700.1.2.1.1
Index
ntcAntCtrlMonControlId
| Column | Syntax | OID |
|---|---|---|
| ntcAntCtrlMonControlId | Enumeration | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.1 |
| ntcAntCtrlInterval | sUnsigned32 | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.2 |
| ntcAntCtrlAntStatus | Enumeration | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.3 |
| ntcAntCtrlTxAllowed | Enumeration | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.4 |
| ntcAntCtrlLatitude | deg.FLOAT-TC-MIBFloat32TC | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.5 |
| ntcAntCtrlLongitude | deg.FLOAT-TC-MIBFloat32TC | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.6 |
| ntcAntCtrlTxMsg | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.7 |
| ntcAntCtrlRxMsg | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.5835.5.2.5700.1.2.1.1.8 |
.1.3.6.1.4.1.5835.5.2.5700.1.3.1
· 3 columns
Alarm Status table
ntcAntCtrlAlarmStatsEntry
.1.3.6.1.4.1.5835.5.2.5700.1.3.1.1
| Column | Syntax | OID |
|---|---|---|
| ntcAntCtrlAlarmStatsControlId | Enumeration | .1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.1 |
| ntcAntCtrlCommErrorStat | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.2 |
| ntcAntCtrlAntFailureStat | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.5700.1.3.1.1.3 |
ntcAntCtrlAlarm
ntcAntCtrlObjects ·
.1.3.6.1.4.1.5835.5.2.5700.1.3
| Object | Syntax | OID |
|---|---|---|
| ntcAntCtrlCommError | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.5700.1.3.2 |
| ntcAntCtrlAntFailure | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.5700.1.3.3 |
Conformance Groups (1)
ntcAntCtrlConfGrpV1Standard .1.3.6.1.4.1.5835.5.2.5700.2.2.1
Members (22)
Compliance Statements (1)
ntcAntCtrlConfCompV1Standard .1.3.6.1.4.1.5835.5.2.5700.2.1.1
Dependencies (6) 5 direct · 1 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- FLOAT-TC-MIBrfc
- NEWTEC-MAIN-MIBnewtec
- NEWTEC-TC-MIBnewtec
- SNMPv2-CONFrfc
- NEWTEC-ANTENNA-CONTROLLER-MIBnewtecselected